scholarly journals A New Cr3+ Electrochemical Sensor Based on ATNA/Nafion/Glassy Carbon Electrode

Materials ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 2695
Author(s):  
Reda M. El-Shishtawy ◽  
Mohammed M. Rahman ◽  
Tahir Ali Sheikh ◽  
Muhammad Nadeem Arshad ◽  
Fatimah A. M. Al-Zahrani ◽  
...  

A new electrochemical sensor of metal cation in an aqueous solution based on homobifunctional tridentate disulfide Schiff base and named 1,1′-(-((disulfanediylbis(2,1-phenylene))bis(azaneylylidene))bis(methaneylylidene))bis(naphthalene-2-ol) (ATNA) was easily obtained quantitatively from the condensation reaction of 2-hydroxy-1-naphthaldehyde and 2-aminothiophenol, and then fully characterized by spectroscopic techniques for structure elucidation. The molecular structure of ATNA was also confirmed by a single-crystal X-ray diffraction study to reveal a new conformation in which the molecule was stabilized by the O–H…N type intramolecular hydrogen bonding interactions in both moieties. The ATNA was used as a selective electrochemical sensor for the detection of chromium ion (Cr3+). A thin film of ATNA was coated on to the flat surface of glassy carbon electrode (GCE) followed by 5 % ethanolic Nafion in order to make the modified GCE (ATNA/Nafion/GCE) as an efficient and sensitive electrochemical sensor. It was found to be very effective and selective against Cr3+ cations in the company of other intrusive heavy metal cations such as Al3+, Ce3+, Co2+, Cu2+, Ga3+, Hg2+, Mn2+, Pb2+, and Y3+. The detection limit at 3 S/N was found to be 0.013 nM for Cr3+ ions within the linear dynamic range (LDR) (0.1 nM–10.0 mM) of Cr3+ ions with r2 = 0.9579. Moreover; this work instigates a new methodology for developing the sensitive as well as selective electrochemical toxic cationic sensors in the field of environmental and health care.

RSC Advances ◽  
2018 ◽  
Vol 8 (35) ◽  
pp. 19754-19764 ◽  
Author(s):  
Mohammed M. Rahman ◽  
Tahir Ali Sheikh ◽  
Reda M. El-Shishtawy ◽  
Muhammad Nadeem Arshad ◽  
Fatimah A. M. Al-Zahrani ◽  
...  

A new Schiff base named 1,1′-(-(naphthalene-2,3-diylbis(azanylylidene))bis(methanylylidene))bis(naphthalen-2-ol) (NDNA) was synthesized by condensation reaction and then characterized by spectroscopic techniques for structure elucidation.


2021 ◽  
Vol 2 (1) ◽  
pp. 24-34
Author(s):  
M. Mahmud Alam ◽  
◽  
M. T. Uddin ◽  
Mohammed M. Rahman ◽  
Abdullah M. Asiri ◽  
...  

The 4-NPHyd (4-nitrophenylhydrazine) electrochemical sensor assembled using wet-chemically prepared ZnO/SnO2 nanoparticle (NPs) decorated a glassy carbon electrode (GCE) with conductive Nafion binder. The synthesized NPs characterized by XPS, ESEM, EDS, and XRD analysis. The calibration of the proposed sensor obtained from current versus concentration of 4-NPHyd found linear over a concentration (0.1 nM ~ 0.01 mM) of 4-NPHyd, which denoted as the dynamic range (LDR) for detection of 4-NPHyd. The 4-NPHyd sensor sensitivity calculated using the LDR slope considering the active surface of GCE (0.0316 cm2), which is equal to be 7.6930 µAµM/cm2, an appreciable value. The detection limit (LOD) at signal/noise (S/N = 3) estimated, and outstanding lower value at 94.63±4.73 pM perceived. The analytical parameters such as reproducibility, long-term performing ability and response time are found as appreciable. Finally, the projected sensor shows exceptional performances in the detection of 4-NPHyd in environmental samples.


2020 ◽  
Vol 16 (4) ◽  
pp. 424-437
Author(s):  
Kubra Ozturk ◽  
Nurgul K. Bakirhan ◽  
Sibel A. Ozkan ◽  
Bengi Uslu

Background:: new and selective electrochemical sensor was developed for the determination of levocetirizine dihydrochloride, which is an antihistaminic drug. Method:: The investigation was performed by using cyclic, differential pulse and square wave voltammetric methods on the β-cyclodextrin modified glassy carbon electrode. It is thereby planned to obtain information about levocetirizine determination and its mechanism. Result:: The efficiency of experimental parameters including pH, scan rate, and accumulation potential and time on the anodic response of levocetirizine dihydrochloride was studied. By employing the developed method and under optimized conditions, the current showed linear dependence with a concentration in the range between 2 × 10-8 M and 6 × 10-6 M in pH 2.0 Britton Robinson (BR) buffer. Conclusion:: The achieved limits of detection and quantification were found as 3.73 × 10-10 M and 1.24 × 10-9 M, respectively. In addition, the possibility of applying the developed sensor for real sample analysis was investigated, so β-cyclodextrin modified glassy carbon electrode was used to determine levocetirizine dihydrochloride in Xyzal® tablet dosage form. Finally, this sensor was successfully applied to the real sample as a selective, simple, reproducible, repeatable electrochemical sensor.


Foods ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 1743
Author(s):  
Qianhui Gu ◽  
Chaoqun Lu ◽  
Kangwen Chen ◽  
Xingguang Chen ◽  
Pengfei Ma ◽  
...  

The rapid quantification of capsaicinoids content is very important for the standardization of pungent taste degree and flavor control of soy sauce and pot-roast meat products. To rapidly quantify the capsaicinoids content in soy sauce and pot-roast meat products, an electrochemical sensor based on β-cyclodextrin/carboxylated multi-wall carbon nanotubes was constructed and the adsorptive stripping voltammetry method was used to enrich samples in this study. The results showed that the excellent performance of the established electrochemical sensor was mostly because β-cyclodextrin caused the relative dispersion of carboxylated multi-wall carbon nanotubes on the glassy carbon electrode surface. Capsaicin and dihydrocapsaicin had similar electrochemical behavior, so the proposed method could determine the total content of capsaicinoids. The linearity of capsaicinoids content was from 0.5 to 100 μmol/L and the detection limit was 0.27 μmol/L. The recovery rates of different capsaicinoids content were between 83.20% and 136.26%, indicating the proposed sensor could realize trace detection of capsaicinoids content in sauce and pot-roast meat products. This work provides a research basis for pungent taste degree standardization and flavor control in the food industry.


The Analyst ◽  
2018 ◽  
Vol 143 (1) ◽  
pp. 297-303 ◽  
Author(s):  
Yang Gao ◽  
Xiufeng Wu ◽  
Hui Wang ◽  
Wenbo Lu ◽  
Mandong Guo

The highly sensitive and selective electrochemical sensor of hesperidin based on gold nanoparticles (AuNPs) and reduced graphene oxide (rGO) modified glassy carbon electrode (GCE) is reported.


2014 ◽  
Vol 6 (23) ◽  
pp. 9375-9382 ◽  
Author(s):  
Xiaojuan Zhao ◽  
Xiaohong Xia ◽  
Shengjiao Yu ◽  
Chunming Wang

An electrochemical sensor for the sensitive determination of honokiol was successfully constructed based on MoS2/graphene nanohybrid.


Sign in / Sign up

Export Citation Format

Share Document