scholarly journals C-S-H Pore Size Characterization Via a Combined Nuclear Magnetic Resonance (NMR)–Scanning Electron Microscopy (SEM) Surface Relaxivity Calibration

Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1779 ◽  
Author(s):  
Christoph Naber ◽  
Florian Kleiner ◽  
Franz Becker ◽  
Long Nguyen-Tuan ◽  
Christiane Rößler ◽  
...  

A new method for the nuclear magnetic resonance (NMR) surface relaxivity calibration in hydrated cement samples is proposed. This method relies on a combined analysis of 28-d hydrated tricalcium silicate samples by scanning electron microscopy (SEM) image analysis and 1H-time-domain (TD)-NMR relaxometry. Pore surface and volume data for interhydrate pores are obtained from high resolution SEM images on surfaces obtained by argon broad ion beam sectioning. These data are combined with T2 relaxation times from 1H-TD-NMR to calculate the systems surface relaxivity according to the fast exchange model of relaxation. This new method is compared to an alternative method that employs sequential drying to calibrate the systems surface relaxivity.

Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 51
Author(s):  
Michela Relucenti ◽  
Giuseppe Familiari ◽  
Orlando Donfrancesco ◽  
Maurizio Taurino ◽  
Xiaobo Li ◽  
...  

Several imaging methodologies have been used in biofilm studies, contributing to deepening the knowledge on their structure. This review illustrates the most widely used microscopy techniques in biofilm investigations, focusing on traditional and innovative scanning electron microscopy techniques such as scanning electron microscopy (SEM), variable pressure SEM (VP-SEM), environmental SEM (ESEM), and the more recent ambiental SEM (ASEM), ending with the cutting edge Cryo-SEM and focused ion beam SEM (FIB SEM), highlighting the pros and cons of several methods with particular emphasis on conventional SEM and VP-SEM. As each technique has its own advantages and disadvantages, the choice of the most appropriate method must be done carefully, based on the specific aim of the study. The evaluation of the drug effects on biofilm requires imaging methods that show the most detailed ultrastructural features of the biofilm. In this kind of research, the use of scanning electron microscopy with customized protocols such as osmium tetroxide (OsO4), ruthenium red (RR), tannic acid (TA) staining, and ionic liquid (IL) treatment is unrivalled for its image quality, magnification, resolution, minimal sample loss, and actual sample structure preservation. The combined use of innovative SEM protocols and 3-D image analysis software will allow for quantitative data from SEM images to be extracted; in this way, data from images of samples that have undergone different antibiofilm treatments can be compared.


2016 ◽  
Vol 16 (4) ◽  
pp. 3383-3387 ◽  
Author(s):  
Toichiro Goto ◽  
Nahoko Kasai ◽  
Rick Lu ◽  
Roxana Filip ◽  
Koji Sumitomo

Interfaces between single neurons and conductive substrates were investigated using focused ion beam (FIB) milling and subsequent scanning electron microscopy (SEM) observation. The interfaces play an important role in controlling neuronal growth when we fabricate neuron-nanostructure integrated devices. Cross sectional images of cultivated neurons obtained with an FIB/SEM dual system show the clear affinity of the neurons for the substrates. Very few neurons attached themselves to indium tin oxide (ITO) and this repulsion yielded a wide interspace at the neuron-ITO interface. A neuron-gold interface exhibited partial adhesion. On the other hand, a neuron-titanium interface showed good adhesion and small interspaces were observed. These results are consistent with an assessment made using fluorescence microscopy. We expect the much higher spatial resolution of SEM images to provide us with more detailed information. Our study shows that the interface between a single neuron and a substrate offers useful information as regards improving surface properties and establishing neuron-nanostructure integrated devices.


2020 ◽  
pp. 108201322096262
Author(s):  
Mengmeng Jiang ◽  
Jun Sun ◽  
Mohammed Obadi ◽  
Xiting Bai ◽  
Wenxue Zhu

The aim of this study was to study the strengthening effect of ultrasonic vacuum technique on the drying kinetics, moisture distribution, and microstructure of honey using low-field nuclear magnetic resonance and scanning electron microscopy. Results showed that ultrasonic vacuum drying technique could substantially shorten the drying time from 600 to 60 min, compared with vacuum drying. The sonochemical effects of ultrasonic vacuum drying were enhanced with the increased ultrasonic power and were more obvious in the initial stage of drying. This finding is consistent with the effective water diffusion coefficient results. The non-linear fitting analysis of experimental data on seven kinds of thin-layer drying mathematical models showed that logarithmic model is more suitable for describing the law of moisture change in honey during ultrasonic vacuum drying than the other models because of its higher regression coefficient value (≥0.99) and smaller reduced chi-square and root mean square error values (≤0.01). In addition, low-field nuclear magnetic resonance results showed that the increase in ultrasonic power accelerated the migration of bound water to immobilized water in honey samples. Scanning electron microscopy results showed that the porous structure formed by increasing the ultrasonic power is also conducive to the rapid migration and drying of moisture. In conclusion, ultrasonic vacuum drying technique is an effective and safe way for drying viscous materials compared with vacuum drying technique.


Sign in / Sign up

Export Citation Format

Share Document