scholarly journals Novel Coating to Minimize Corrosion of Glass-Ceramics for Dental Applications

Materials ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1215 ◽  
Author(s):  
Shu-Min Hsu ◽  
Fan Ren ◽  
Zhiting Chen ◽  
Mijin Kim ◽  
Chaker Fares ◽  
...  

The effect of a novel silicon carbide (SiC) coating on the chemical durability of a fluorapatite glass-ceramic veneer was investigated by examining weight loss and ion release levels. The hypothesis that this novel coating will exhibit significant corrosion resistance was tested. Inductively coupled plasma atomic emission spectrometer (ICP) was used for ion concentration determination and scanning electron microscopy (SEM) for surface morphology analyses. Samples were immersed in pH 10 and pH 2 buffer solutions to represent extreme conditions in the oral cavity. Analyses were done at 15 and 30 days. The SiC coated group demonstrated significant reduction in weight loss across all solutions and time points (p < 0.0001). Ion release analyses demonstrated either a marginally lower or a significantly lower release of ions for the SiC-coated disks. SEM analysis reveals planarization of surfaces by the SiC-coated group. The surfaces of coated samples were not as corroded as the non-coated samples, which is indicative of the protective nature of these coatings. In conclusion, SiC is a novel coating that holds promise for improving the performance of ceramic materials used for dental applications.

Materials ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 3655
Author(s):  
Shu-Min Hsu ◽  
Fan Ren ◽  
Christopher D. Batich ◽  
Arthur E. Clark ◽  
Dan Neal ◽  
...  

The effect of pH changes on the chemical durability of dental glass–ceramic materials was evaluated using weight loss and ion release levels. The hypothesis that increased pH changes will exhibit greater corrosion was investigated. The ion concentration was analyzed using inductively coupled plasma atomic emission spectrometer (ICP). The surface compositions were investigated using X-ray photoelectron spectroscopy (XPS). The surface morphologies were examined using scanning electron microscopy (SEM). Dental glass–ceramics were tested in constant immersion, 3-day cycling, and 1-day cycling with pH 10, pH 2, and pH 7 for 3, 15, and 30 days. The 1-d cycling group demonstrated the highest levels of weight loss compared with 3-d cycling and constant immersion. For the ion release, Si4+ and Ca2+ had the highest rates of release in 1-d cycling, whereas the Al3+ release rate with constant pH 2 was highest. The alteration/passivation layer that was formed on the surface of disks possibly prevented further dissolution of pH 10 corroded disks. XPS analysis demonstrated different surface compositions of corroded disks in pH 10 and pH 2. Si4+, K+, Na+, Al3+, and Ca2+ were detected on the surface of corroded pH 10 disks, whereas a Si4+ and P5+-rich surface formed on corroded pH 2 disks. SEM results demonstrated rougher surfaces for corroded disks in cycling conditions and pH 2 constant immersion. In conclusion, increased pH changes significantly promote the corrosion of dental glass–ceramic materials.


Coatings ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 98
Author(s):  
María Arregui ◽  
Florian Latour ◽  
Francisco Javier Gil ◽  
Román A. Pérez ◽  
Luis Giner-Tarrida ◽  
...  

Ion release from dental implants and prosthetic restoration can affect osteointegration and implant viability over a long period of time. Therefore, the aim of this study was to study the ion release from implants and crowns, with and without intermediate anodized abutments, in two different media, simulating clinical conditions. The implants, intermediate prosthetic abutments and Cr–Co crowns were divided into two groups depending on the media: Hanks’ solution and 1% lactic acid, simulating body fluids and microbiologically conditioned fluids, respectively. The study followed the ISO 10271:2011 and 10993-15:2000 standards modified to simulate the replacement of fluids in the oral environment. The ions’ release was measured by inductively coupled plasma mass spectroscopy (ICP-EOS), and only aluminum, chromium, cobalt, titanium and vanadium were identified. Ion concentration was higher in lactic acid than in Hanks’ solution at all time points (p < 0.05). Only vanadium showed a very low ion release in lactic acid, with no statistically significant differences from the ion release in Hanks’ solution (p = 0.524). Both anodized abutments and the immersion medium influenced the release of ions and affected the corrosion of these structures. The presence of an intermediate anodized abutment also affected ion release, as the level of ions was lower in groups with this component.


2018 ◽  
Vol 281 ◽  
pp. 564-569
Author(s):  
Ya Ming Wang ◽  
Yong Fa Song ◽  
Shun Lan Deng ◽  
Osaka Akiyoshi ◽  
Guang Xin Wang ◽  
...  

Anatase-type titanium dioxide oxide layer was formed on the surface of titanium alloy by chemical oxidation. 0.9 um thick anatase was obtained by soaking in a mixed solution of a certain proportion of hydrogen peroxide and hydrochloric acid and then heat treatment. The surface morphology, phase structures and composition of oxide layers were characterized by scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). Thickness of titania coating was measured by the ball pit gauge. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) was used to detect the change of Ca ion and P ion concentration in solution. The results showed that anatase layers deposited apatite within 4 days accompanying the decrease of pH when soaked in simulated human body fluid (SBF). Ion exchange between the negative ions and calcium ions in SBF is proposed as the mechanism operative to favor the deposition on apatite.


2018 ◽  
Author(s):  
Danila Barskiy ◽  
Lucia Ke ◽  
Xingyang Li ◽  
Vincent Stevenson ◽  
Nevin Widarman ◽  
...  

<p>Hyperpolarization techniques based on the use of parahydrogen provide orders of magnitude signal enhancement for magnetic resonance spectroscopy and imaging. The main drawback limiting widespread applicability of parahydrogen-based techniques in biomedicine is the presence of organometallic compounds (the polarization transfer catalysts) in solution with hyperpolarized contrast agents. These catalysts are typically complexes of platinum-group metals and their administration in vivo should be avoided.</p> <p><br></p><p>Herein, we show how extraction of a hyperpolarized compound from an organic phase to an aqueous phase combined with a rapid (less than 10 seconds) Ir-based catalyst capture by metal scavenging agents can produce pure parahydrogen-based hyperpolarized contrast agents as demonstrated by high-resolution nuclear magnetic resonance (NMR) spectroscopy and inductively coupled plasma atomic emission spectroscopy (ICP-AES). The presented methodology enables fast and efficient means of producing pure hyperpolarized aqueous solutions for biomedical and other uses.</p>


2018 ◽  
Author(s):  
Danila Barskiy ◽  
Lucia Ke ◽  
Xingyang Li ◽  
Vincent Stevenson ◽  
Nevin Widarman ◽  
...  

<p>Hyperpolarization techniques based on the use of parahydrogen provide orders of magnitude signal enhancement for magnetic resonance spectroscopy and imaging. The main drawback limiting widespread applicability of parahydrogen-based techniques in biomedicine is the presence of organometallic compounds (the polarization transfer catalysts) in solution with hyperpolarized contrast agents. These catalysts are typically complexes of platinum-group metals and their administration in vivo should be avoided.</p> <p><br></p><p>Herein, we show how extraction of a hyperpolarized compound from an organic phase to an aqueous phase combined with a rapid (less than 10 seconds) Ir-based catalyst capture by metal scavenging agents can produce pure parahydrogen-based hyperpolarized contrast agents as demonstrated by high-resolution nuclear magnetic resonance (NMR) spectroscopy and inductively coupled plasma atomic emission spectroscopy (ICP-AES). The presented methodology enables fast and efficient means of producing pure hyperpolarized aqueous solutions for biomedical and other uses.</p>


2020 ◽  
Vol 86 (5) ◽  
pp. 16-21
Author(s):  
T. A. Karimova ◽  
G. L. Buchbinder ◽  
S. V. Kachin

Calibration by the concentration ratio provides better metrological characteristics compared to other calibration modes when using the inductively coupled plasma atomic emission spectrometry (ICP-AES) for analysis of geological samples and technical materials on their base. The main reasons for the observed improvement are: i) elimination of the calibration error of measuring vessels and the error of weighing samples of the analyzed materials from the total error of the analysis; ii) high intensity of the lines of base element; and iii) higher accuracy of measuring the ratio of intensities compared to that of measuring the absolute intensities. Calcium oxide is better suited as a base when using calibration by the concentration ratio in analysis of carbonate rocks, technical materials, slags containing less than 20% SiO2 and more than 20% CaO. An equation is derived to calculate the content of components determined in carbonate materials when using calibration by the concentration ratio. A method of ICP-AES with calibration by the concentration ratio is developed for determination of CaO (in the range of contents 20 – 100%), SiO2 (2.0 – 35%), Al2O3 (0.1 – 30%), MgO (0.1 – 20%), Fe2O3 (0.5 – 40%), Na2O (0.1 – 15%), K2O (0.1 – 5%), P2O5 (0.001 – 2%), MnO (0.01 – 2%), TiO2 (0.01 – 2.0%) in various carbonate materials. Acid decomposition of the samples in closed vessels heated in a HotBlock 200 system is proposed. Correctness of the procedure is confirmed in analysis of standard samples of rocks. The developed procedure was used during the interlaboratory analysis of the standard sample of slag SH17 produced by ZAO ISO (Yekaterinburg, Russia).


Sign in / Sign up

Export Citation Format

Share Document