scholarly journals Effect of Antibacterial Silver-Releasing Filler on the Physicochemical Properties of Poly(Methyl Methacrylate) Denture Base Material

Materials ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4146 ◽  
Author(s):  
Grzegorz Chladek ◽  
Katarzyna Pakieła ◽  
Wojciech Pakieła ◽  
Jarosław Żmudzki ◽  
Marcin Adamiak ◽  
...  

Colonization of polymeric dental prosthetic materials by yeast-like fungi and the association of these microorganisms with complications occurring during prosthetic treatment are important clinical problems. In previously presented research, submicron inorganic particles of silver sodium hydrogen zirconium phosphate (S–P) were introduced into poly(methyl methacrylate) (PMMA) denture base material which allowed for obtaining the antimicrobial effect during a 90 day experiment. The aim of the present study was to investigate the flexural strength, impact strength, hardness, wear resistance, sorption, and solubility during three months of storage in distilled water. With increasing S–P concentration after 2 days of conditioning in distilled water, reduced values of flexural strength (107–72 MPa), impact strength (18.4–5.5 MPa) as well as enhanced solubility (0.95–1.49 µg/mm3) were registered, but they were at acceptable levels, and the sorption was stable. Favorable changes included increased hardness (198–238 MPa), flexural modulus (2.9–3.3 GPa), and decreased volume loss during wear test (2.9–0.2 mm3). The percentage changes of the analyzed properties during the 90 days of storage in distilled water were similar for all materials.

Materials ◽  
2016 ◽  
Vol 9 (5) ◽  
pp. 328 ◽  
Author(s):  
Grzegorz Chladek ◽  
Katarzyna Basa ◽  
Anna Mertas ◽  
Wojciech Pakieła ◽  
Jarosław Żmudzki ◽  
...  

Author(s):  
Montri Ratanajanchai ◽  
Widchaya Kanchanavasita ◽  
Kallaya Suputtamongkol ◽  
Amonrat Wonglamsam ◽  
Sirinporn Thamapipol ◽  
...  

2012 ◽  
Vol 61 (8) ◽  
pp. 1272-1278 ◽  
Author(s):  
Pavle Spasojević ◽  
Dragoslav Stamenković ◽  
Rada Pjanović ◽  
Nevenka Bošković-Vragolović ◽  
Jelena Dolić ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-9 ◽  
Author(s):  
Pavle Spasojevic ◽  
Milorad Zrilic ◽  
Vesna Panic ◽  
Dragoslav Stamenkovic ◽  
Sanja Seslija ◽  
...  

This study investigates a wide range of clinically relevant mechanical properties of poly(methyl methacrylate) (PMMA) denture base materials modified with di-methyl itaconate (DMI) and di-n-butyl itaconate (DBI) in order to compare them to a commercial PMMA denture base material. The commercial denture base formulation was modified with DMI and DBI by replacing up to 10 wt% of methyl methacrylate (MMA) monomer. The specimens were prepared by standard bath curing process. The influence of the itaconate content on hardness, impact strength, tensile, and thermal and dynamic mechanical properties was investigated. It is found that the addition of di-n-alkyl itaconates gives homogenous blends that show decreased glass transition temperature, as well as decrease in storage modulus, ultimate tensile strength, and impact fracture resistance with increase in the itaconate content. The mean values of surface hardness show no significant change with the addition of itaconates. The magnitude of the measured values indicates that the poly(methyl methacrylate) (PMMA) denture base material modified with itaconates could be developed into a less toxic, more environmentally and patient friendly product than commercial pure PMMA denture base material.


2010 ◽  
Vol 21 (1) ◽  
pp. 55-59 ◽  
Author(s):  
Fabiana Gouveia Straioto ◽  
Antonio Pedro Ricomini Filho ◽  
Alfredo Júlio Fernandes Neto ◽  
Altair Antoninha Del Bel Cury

The addition of different polymers, such as polytetrafluorethylene (PTFE), to denture base resins could be an option to modify acrylic resin mechanical properties. This study evaluated the surface hardness, impact and flexural strength, flexural modulus and peak load of 2 acrylic resins, one subjected to a long and another subjected to a short polymerization cycle, which were prepared with or without the addition of 2% PTFE. Four groups were formed according to the polymerization cycle and addition or not of PTFE. Forty specimens were prepared for each test (10 per group) with the following dimensions: hardness (30 mm diameter x 5 mm thick), impact strength (50 x 6 x 4 mm) and flexural strength (64 x 10 x 3.3 mm) test. The results of the flexural strength test allowed calculating flexural modulus and peak of load values. All tests were performed in accordance with the ISO 1567:1999 standard. Data were analyzed statistically by ANOVA and Tukey's test with the level of significance set at 5%. No statistically significant differences (p>0.05) were found for surface hardness. Flexural strength, impact strength and peak load were significantly higher (p<0.05) for resins without added PTFE. The flexural modulus of the acrylic resin with incorporated 2% PTFE polymerized by long cycle was significantly higher (p<0.05) than that of the other resins. Within the limits of this study, it may be concluded that the addition of PTFE did not improve the mechanical properties of the evaluated acrylic resins.


2005 ◽  
Vol 6 (4) ◽  
pp. 93-100 ◽  
Author(s):  
Thomas R. Meng ◽  
Mark A. Latta

Abstract Resistance to impact fracture and high flexural strength are desirable properties of denture base acrylics. The purpose of this laboratory study was to determine the Izod impact strength, the flexural strength, the flexural modulus, and the yield distance for four premium denture resins. Bar specimens 86 x 11 x 3 mm of Lucitone 199, Fricke Hi-I, ProBase Hot, and Sledgehammer Maxipack were fabricated following the manufacturer's instructions for heat processing. The bars were surface finished using silicon carbide paper to 600 grit. Ten specimens from three lots of each material were made (n=30). Flexural strength, flexural modulus, and yield distance were determined by testing the specimens to failure using a three-point test fixture. Izod impact strength was determined using an Izod tester on un-notched specimens generated from the flexural test (n=60). Analysis of variance (ANOVA) and post-hoc Tukey's test were used for statistical comparison of each property. There were significant differences in the physical properties among the denture acrylics tested. Lucitone 199 demonstrated the highest impact strength, flexural strength, and yield distance (p<0.05). Lucitone 199 with an Izod impact strength of 5.5 ± 1.2 N·m, a flexural strength of 99.5 ± 4.5 MPa, and yield distance of 9.9 ± 0.76 mm exhibited statistically greater results than Fricki Hi-I, ProBase Hot, and Sledgehammer Maxipack. Fricki Hi- I with a yield distance of 7.3 ± 1.1 mm was statically greater than ProBase Hot and Sledgehammer Maxipack. Fricki Hi-I, ProBase Hot, and Sledgehammer Maxipack were statistically similar for the Izod impact strength and flexural strength tests performed. ProBase Hot and Sledgehammer Maxipack yielded statistically similar results for all tests performed. Flexural modulus had an inverse relationship to the impact strength, flexural strength, and yield distance. Citation Meng TR, Latta MA. Physical Properties of Four Acrylic Denture Base Resins. J Contemp Dent Pract 2005 November;(6)4:093-100.


2019 ◽  
Vol 2019 ◽  
pp. 1-11 ◽  
Author(s):  
Mohammed M. Gad ◽  
Ahmad M. Al-Thobity ◽  
Ahmed Rahoma ◽  
Reem Abualsaud ◽  
Fahad A. Al-Harbi ◽  
...  

This study is aimed at evaluating the hybrid reinforcement effects of zirconium oxide nanoparticles (nano-ZrO2) and glass fibers (GFs) at different ratios on the flexural and impact strengths of a polymethylmethacrylate (PMMA) denture base. A total of 160 specimens were fabricated from heat-polymerized acrylic resins using the water bath technique. For the control group, the specimens did not receive any additions; for the test group, different concentrations of nano-ZrO2/GFs at 5% of the PMMA polymer were added. The concentrations of nano-ZrO2/GFs were as follows: 5%–0%, 4%–1%, 3%–2%, 2.5%–2.5%, 2%–3%, 1%–4%, and 0%–5%. The flexural strength was measured using the three-point bending test. The impact strength was measured using the Charpy impact test. Results were tabulated and analyzed using one-way analysis of variance (ANOVA) and the Tukey–Kramer multiple comparison test (p≤0.05). The flexural and impact strengths of PMMA-nano-ZrO2 + GF composites were significantly improved when compared with those of pure PMMA (p<0.05). The maximum flexural strength (94.05 ± 6.95 MPa) and impact strength (3.89 ± 0.46 kJ/m2) were obtained with PMMA (2.5%)/nano-ZrO2 + 2.5% GF mixtures and could be used for removable prosthesis fabrication.


Sign in / Sign up

Export Citation Format

Share Document