scholarly journals The Influence of Single-Walled Carbon Nanotubes on the Dynamic Properties of Nematic Liquid Crystals in Magnetic Field

Materials ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4031 ◽  
Author(s):  
Cirtoaje ◽  
Petrescu

This article aims to study the impact of carbon nanotube dispersions in liquid crystals. A theoretical model for the system’s dynamics is presented, considering the elastic continuum theory and a planar alignment of liquid crystal molecules on the nanotube’s surface. Experimental calculation of the relaxation times in the magnetic field was made for two cases: when the field was switched on (τon), and when it was switched off (τoff). The results indicate an increase of the relaxation time by about 25% when the magnetic field was switched off, and a smaller increase (about 10%) when the field was switched on, where both were in good agreement with the theoretical values.

2000 ◽  
Vol 14 (04) ◽  
pp. 139-146 ◽  
Author(s):  
EMIL PETRESCU ◽  
CORNELIA MOTOC ◽  
DOINA MANAILA

The theoretical model proposed by Pieranski et al.3 to describe the phenomena occurring in nematic liquid crystals when the magnetic field is suddenly varied was extended by considering higher powers of the distortion angle for the nematic director. Equations giving the time evolution of the number of extinctions in the light transmission were obtained. These equations depend on some relaxation parameters (the time constants τA and τB intervening when the magnetic field was switched "on" or "off", respectively) and on the ratio of elastic constants. The equations were solved numerically and good agreement with the experimental data was obtained for the nematic MBBA.


1974 ◽  
Vol 29 (2) ◽  
pp. 310-318
Author(s):  
G. Heppke ◽  
F. Schneider

The magnetic field induced elastic deformations of nematic liquid crystals are studied theoretically. In accordance with the theory of Dafermos, two types of elastic deformations are predicted which differ in energy. The properties of the metastable deformations are discussed in detail. Experimental studies have been performed on MBBA using electrical conductivity measurements. Metastable deformations are obtained after rotating the direction of the magnetic field by more than 90° with respect to the direction of the homeotropically aligned sample. The observed conductivity values are in good agreement with theory.


2020 ◽  
Vol 2020 (10) ◽  
pp. 4-11
Author(s):  
Victor Tikhomirov ◽  
Aleksandr Gorlenko ◽  
Stanislav Volohov ◽  
Mikhail Izmerov

The work purpose is the investigation of magnetic field impact upon properties of friction steel surfaces at fit stripping with tightness through manifested effects and their wear visually observed. On the spots of a real contact the magnetic field increases active centers, their amount and saturation with the time of dislocation outlet, and has an influence upon tribo-mating. The external electro-magnetic field promotes the increase of the number of active centers at the expense of dislocations outlet on the contact surface, and the increase of a physical contact area results in friction tie strengthening and growth of a friction factor. By the example of friction pairs of a spentonly unit in the suspension of coach cars there is given a substantiation of actuality and possibility for the creation of technical devices with the controlled factor of friction and the stability of effects achieved is also confirmed experimentally. Investigation methods: the fulfillment of laboratory physical experiments on the laboratory plant developed and patented on bush-rod samples inserted with the fit and tightness. The results of investigations and novelty: the impact of the magnetic field upon the value of a stripping force of a press fit with the guaranteed tightness is defined. Conclusion: there is a possibility to control a friction factor through the magnetic field impact upon a friction contact.


2020 ◽  
Vol 30 (6) ◽  
pp. 353-361
Author(s):  
Rebecca S. Dewey ◽  
Rachel Gomez ◽  
Chris Degg ◽  
David M. Baguley ◽  
Paul M. Glover

The sensation of phantom motion or exhibition of bodily sway is often reported in the proximity of an MR scanner. It is proposed that the magnetic field stimulates the vestibular system. There are a number of possible mechanisms responsible, and the relative contributions of susceptibility on the otolithic receptors and the Lorentz force on the cupulae have not yet been explored. This exploratory study aims to investigate the impact of being in the proximity of a 7.0 T MR scanner. The modified clinical test of sensory interaction on balance (mCTSIB) was used to qualitatively ascertain whether or not healthy control subjects who passed the mCTSIB in normal conditions 1) experienced subjective sensations of dizziness, vertigo or of leaning or shifting in gravity when in the magnetic field and 2) exhibited visibly increased bodily sway whilst in the magnetic field compared to outside the magnetic field. Condition IV of the mCTSIB was video recorded outside and inside the magnetic field, providing a semi-quantitative measure of sway. For condition IV of the mCTSIB (visual and proprioceptive cues compromised), all seven locations/orientations around the scanner yielded significantly more sway than at baseline (p < 0.01 FDR). A Student’s t-test comparing the RMS velocity of a motion marker on the upper arm during mCTSIB condition IV showed a significant increase in the amount of motion exhibited in the field (T = 2.59; d.f. = 9; p = 0.029) compared to outside the field. This initial study using qualitative measures of sway demonstrates that there is evidence for MR-naïve individuals exhibiting greater sway while performing the mCTSIB in the magnetic field compared to outside the field. Directional polarity of sway was not significant. Future studies of vestibular stimulation by magnetic fields would benefit from the development of a sensitive, objective measure of balance function, which can be performed inside a magnetic field.


1972 ◽  
Vol 50 (18) ◽  
pp. 2122-2137
Author(s):  
R. Turner ◽  
J. F. Cochran

According to Van Gelder the microwave absorption by a thin metal film in the presence of a static magnetic field normal to the film contains a series of peaks as the magnetic field is varied. In the present paper it is argued that these peaks correspond to Doppler-shifted cyclotron resonances of the carriers in the metal due to the quantization of electron momenta normal to the plane of the film. A simple quantum calculation is presented for the case of free electrons where the film is thin enough that to first order the microwave fields within are determined only by the boundary conditions and Maxwell's equations. The quantum expression is in good agreement with the absorption calculated using semiclassical arguments which can be readily extended to more complicated Fermi surfaces.


2018 ◽  
Vol 145 ◽  
pp. 03003
Author(s):  
Polya Dobreva ◽  
Monio Kartalev ◽  
Olga Nitcheva ◽  
Natalia Borodkova ◽  
Georgy Zastenker

We investigate the behaviour of the plasma parameters in the magnetosheath in a case when Interball-1 satellite stayed in the magnetosheath, crossing the tail magnetopause. In our analysis we apply the numerical magnetosheath-magnetosphere model as a theoretical tool. The bow shock and the magnetopause are self-consistently determined in the process of the solution. The flow in the magnetosheath is governed by the Euler equations of compressible ideal gas. The magnetic field in the magnetosphere is calculated by a variant of the Tsyganenko model, modified to account for an asymmetric magnetopause. Also, the magnetopause currents in Tsyganenko model are replaced by numericaly calulated ones. Measurements from WIND spacecraft are used as a solar wind monitor. The results demonstrate a good agreement between the model-calculated and measured values of the parameters under investigation.


2020 ◽  
Vol 62 (5) ◽  
pp. 669
Author(s):  
С.А. Гудин ◽  
Н.И. Солин

Experimental and theoretical investigations of the resistance of the La1.2Sr1.8Mn2O7 single crystal in magnetic fields from 0 to 90 kOe and in the temperature range from 75 to 300 K has been studied. The magnetoresistance is determined by the “spin-polaron” and “orientation” conduction mechanisms. Using the method of separating contributions to the magnetoresistance from several conduction mechanisms, the observed magnetoresistance of La1.2Sr1.8Mn2O7 manganite in the temperature range of 75-300 K is described, good agreement between the calculated and experimental data is obtained. In a magnetic field of 0 and 90 kOe, the temperature dependences of the size of the spin polaron (in relative units) are calculated for the temperature range 75–300 K. It is shown, that the КМС value is determined by an increase in the linear size of the spin polaron (along the magnetic field), i.e. the main role in the magnitude of the colossal magnetoresistance is made by the change in the size of the magnetic inhomogeneities of the crystal.


1978 ◽  
Vol 33 (7) ◽  
pp. 749-760 ◽  
Author(s):  
G. E. J. Eggermont ◽  
P. W. Hermans ◽  
L. J. F. Hermans ◽  
H. F. P. Knaap ◽  
J. J. M. Beenakker

In a rarefied polyatomic gas streaming through a rectangular channel, an external magnetic field produces a heat flux perpendicular to the flow direction. Experiments on this “viscom agnetic heat flux” have been performed for CO, N2, CH4 and HD at room temperature, with different orientations of the magnetic field. Such measurements enable one to separate the boundary layer contribution from the purely bulk contribution by means of the theory recently developed by Vestner. Very good agreement is found between the experimentally determined bulk contribution and the theoretical Burnett value for CO, N2 and CH4 , yet the behavior of HD is found to be anomalous.


2020 ◽  
Vol 22 (1-2) ◽  
pp. 58-64
Author(s):  
Teodora Gavrilov ◽  
◽  
Karolina Kasaš-Lažetić ◽  
Kristian Haška ◽  
Miroslav Prša

In this paper, the analysis of magnetic field distribution of overhead mixed power line (20 kV/0.4 kV) supported by reinforced concrete towers, named MNL-12 is presented. The impact of ferromagnetic, conductive parts of the pylons (reinforcing bars, billets and cross arm beams) on magnetic field distribution is investigated. The numerical calculations were performed in COMSOL Multiphysics program package on simplified 2D model. The main goal of the calculations was to examine the impact of currents induced in ferromagnetic conductive parts on magnetic field produced by currents in the power system’s conductors. The calculation results are presented graphically, as the diagrams of the magnetic flux density magnitude distribution in the tower plan, normal to the system’s axe. The calculation results demonstrated that the magnetic field of induced currents decreases the magnetic field produced by the currents of overhead power system.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Robert W Biederman ◽  
Loretta Gevenosky ◽  
Geetha Rayarao ◽  
RONALD WILLIAMS ◽  
Richard Lombardi ◽  
...  

Introduction: The evolution of pacemaker/ICD safety in the magnetic field has triggered considerable interest in more clinical routine use. However, many limitations to widespread adoption of this seemingly implausible idea just a few years ago remain: unresolved impact of the high magnetic field, RF amplitude and oscillatory forces on electronics with possible high field damage to capacitor, solenoid and microcircuitry. However, given recent vender refinements over the last 10 years, we hypothesized that the impact on such circuitry may be far less than expected. Method: Consecutive interrogation of 940 pts who underwent clinically indicated MRI were evaluated over 5 years. This cohort was comprised of neuro/neurosurgical (72%), orthopedic (11%) and cardiac (17%) cases. Routine interrogation was performed within 10 min of entry into the bore of a dedicated Cardiac MRI (GE, 1.5T, WI). As well, reinterrogation was performed within 10 min of departure MRI (average 21±12min). At the time of interrogation pre and post MRI, a separate, repeat interrogation was performed within 5 min of each other such that 2 sets of PM/ICD parameters were obtained pre and post MRI. Result: No complications to either pt or device occurred during the MRI comprising 564 PMs and 376 ICDs. A cardiologist was present guiding the interrogation, configuration, and reconfiguration of the PM/ICD as well was present for entire MRI. There were no significant differences in common clinical parameters. More importantly, there was no difference in any parameter when compared in any order pre to post MRI scan. See Table. Conclusion: Intrinsic variability and inherent changes triggered by MRI environments are clinically insignificant and statistically negligible thereby removing yet another of the last remaining fears and apprehensions for primary PM/ICD failure and destruction as we move towards a more uniform acceptance of this technology for clinically meaningful use, dissemination and acceptance.


Sign in / Sign up

Export Citation Format

Share Document