scholarly journals The Effect of Er,Cr:YSGG and Diode Laser Applications on Dental Implant Surfaces Contaminated with Acinetobacter Baumannii and Pseudomonas Aeruginosa

Materials ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2073 ◽  
Author(s):  
Adel S. Alagl ◽  
Marwa Madi ◽  
Sumit Bedi ◽  
Faisal Al Onaizan ◽  
Zainab S. Al-Aql

Treatment of peri-implantitis through several implant surface decontamination techniques have been reported, however, some of them can negatively alter the implant surface or enhance more bacterial resistance. The aim of this in vitro study was to evaluate implant surface decontamination by means of Er,Cr:YSGG and diode lasers. Fifty micro-textured (MTX) dental implants were contaminated with Acinetobacter baumannii (n = 25) and with Pseudomonas aeruginosa (n = 25). All implants were then divided into five groups for the decontamination procedure. In group I (GI), decontamination was done with an Er,Cr:YSGG laser (2780 nm), while in group II (GII) decontamination was performed using photodynamic therapy (a 650 nm diode laser). In Group III (GIII) decontamination was performed with photodynamic therapy (an 808 nm diode laser), and in group IV (GIV) decontamination was performed with 0.12% chlorhexidine. Group V (GV) was the control group with no decontamination. After decontamination, colony forming units (CFU) were counted and implants were prepared for SEM analysis. A significant difference (p < 0.001) was observed for GI compared to the other groups, and also for GIV compared to both GII and GIII. The Er,Cr:YSGG laser (GI) showed the best results in decontaminating the implant surface. Chlorhexidine (GIV), proved to be better in decontaminating the implant surface than photodynamic therapy GII and diode laser GIII. No significant difference was found between group GII and GIII. The SEM analysis showed no significant change in the implant surface topography. The results of this study suggest that the Er,Cr:YSGG laser can be considered as an effective technique for reducing bacteria contamination on implant surfaces.

2020 ◽  
Vol 11 (2) ◽  
pp. 126-134
Author(s):  
Narges Naghsh ◽  
Mahdi Kachuie ◽  
Marzie Kachuie ◽  
Reza Birang

Introduction: Dentin hypersensitivity is a common oral problem that occurs as a short and sharp pain. There are many techniques to treat this condition, the latest of which is laser treatment. The aim of this study was to evaluate the effect of two types of low-power diode lasers (660 nm and 810 nm) on dentin hypersensitivity in order to achieve an acceptable clinical application by adjusting the effective parameters. Methods: In this randomized, double-blind clinical trial, sensitive teeth of 7 patients were divided into three groups with a randomized matching method: group I, treated with 660-nm diode laser irradiation, group II, treated with diode laser 810-nm, and group III, the control group. Irradiation parameters for 660-nm and 810-nm diode lasers were the power of 30 mW and 100 mW respectively, in contact and continuous modes, perpendicular to the tooth surface with a sweeping motion. Treatments were carried out in four sessions at weekly intervals. The data obtained were analyzed with SPSS 22, using one-way repeated measures ANOVA and the LSD (least significant difference) test. The significance level was considered as P≤0.05. Results: There were no significant differences in visual analogue scale (VAS) score changes between the two laser groups after the intervention in the first, second and third weeks compared to the baseline (P>0.05). These changes in the fourth week were significantly higher in the 810-nm laser group compared to the 660-nm laser group (P=0.04), and in the 660-nm laser group, they were more than the control group (P=0.02). The mean VAS scores at 1-week, 1-month and 2-month postoperative intervals were significantly lower in the 810-nm laser group than in the 660-nm laser group, and in the 660-nm laser group, they were less than the control group (P<0.001). Conclusion: The use of 660-nm and 810-nm diode lasers with the power of 30 and 100 mW respectively for 120 seconds was effective in reducing pain in patients with dentin hypersensitivity. However, the effect of the 810-nm laser on reducing the dentin hypersensitivity was more long-lasting than that of the 660-nm laser.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Ayman A. Al-Dharrab ◽  
Seham B. Tayel ◽  
Mona H. Abodaya

Objective. This study aimed to evaluate the effect of different storage solutions that simulate acidic, alkaline, and sebum conditiions on the physical properties of pigmented (colorant elastomer) cosmesil M511 maxillofacial prosthetic material. Materials and Methods. Sixty specimens were prepared according to the manufacturer's instructions and were tested before and after immersion of different storage conditions for six months at 37 °C. The following tests were performed: color changes (group I), solution absorption (group II), surface roughness (group III), and scanning electron microscopy (group IV). Results. There were no significant changes observed in the color and solution absorption tests while surface roughness revealed significant difference between control group and other testing storage medium groups, and this result was supported by SEM analysis that revealed limited surface changes. Conclusions. Cosmaseil material is an acceptable cross-linked formulation that withstands storage in different solutions with variable pH. The addition of pigment cannot vary the physical properties of these materials. Surface roughness test as well as SEM microscopic study showed moderate changes indicating a limited effect on the surface of the material.


2009 ◽  
Vol 7 (4) ◽  
pp. 423-430 ◽  
Author(s):  
Paulo de Tarso Camillo De Carvalho ◽  
Filipe Abdalla dos Reis ◽  
Ana Carulina Guimarães Belchior ◽  
Baldomero Antônio Kato da Silva ◽  
Daniel Martins Pereira ◽  
...  

The aims of this study were to determine whether S. aureus could be killed by toluidine blue-mediated photosensitization in vivo in an animal model. Twelve Wistar rats divided into three groups (n = 12): Group I: Control Group, the wounds were made and submitted to the application of the laser without the drug photosensitizing; Group II: The implementation of wounds received the toluidine blue, without application of laser; Group III: it was used toluidine blue, and application of laser-Indio phosphide Gallium-Aluminum (InGaAIP)  660nm power and density of 20 Joules/cm2. Statistical analysis of CFU by analysis of variance Kruskal-Wallis test shows significant intraoperative difference, photodynamic therapy group (p 0, 05), the Dunns post hoc test shows significant difference between Group I when compared to Group II treated with LLLT (p 0001). The results of this study show that photodynamic therapy with toluidine blue has reduced the number of Staphylococcus aureus in vivo.


2020 ◽  
Vol 53 (2) ◽  
pp. 71
Author(s):  
Nanik Zubaidah ◽  
Agus Subiwahjudi ◽  
Dinda Dewi Artini ◽  
Karina Erda Saninggar

Background: A successful root canal treatment eliminates pathogenic bacteria from infected root canals. The most common bacteria in root canal infections is Enterococcus faecalis (E. faecalis), due to its resistance to medicament and root canal irrigation. A photodynamic therapy (PDT) is a method of root canal disinfection that uses a combination of photosensitisers and light activation to eliminate bacteria in the root canal. The duration of the PDT irradiation results in the production of singlet oxygen and reactive oxygen species (ROS) to eliminate the E. faecalis bacteria. Purpose: To analyse the differences in the duration exposure of photodynamic therapy against the E. faecalis bacteria. Methods: The E. faecalis bacteria culture was divided into seven eppendorf tubes. Group I was a control group, and group II, III, IV, V, VI and VII were treated using PDT consisting of Toluidine Blue O (TBO) photosensitiser and light source irradiation for ten, 20, 30, 40, 50 and 60 seconds, respectively. After incubation, the number of bacteria was calculated by the Quebec Colony Counter and analysed using the Kruskal–Wallis test and the Mann–Whitney test (p <0.05). Results: There was a significant difference between the number of E. faecalis bacteria colonies in each treatment group (p <0.05). Group VI and VII, which had a longer exposure to PDT, showed a smaller amount of E. faecalis bacteria. Conclusion: The longer exposure of PDT results in a smaller amount of E. faecalis bacteria. The light irradiation of 50 seconds is the most effective to eliminate E. faecalis bacteria.


Author(s):  
Pier Poli ◽  
Francisley Avila Souza ◽  
Mattia Manfredini ◽  
Carlo Maiorana ◽  
Mario Beretta

Not required for Clinical case letters according to the authors' guidelines.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1670 ◽  
Author(s):  
Wölfle-Roos JV ◽  
Katmer Amet B ◽  
Fiedler J ◽  
Michels H ◽  
Kappelt G ◽  
...  

Background: Uncemented implants are still associated with several major challenges, especially with regard to their manufacturing and their osseointegration. In this study, a novel manufacturing technique—an optimized form of precision casting—and a novel surface modification to promote osseointegration—calcium and phosphorus ion implantation into the implant surface—were tested in vivo. Methods: Cylindrical Ti6Al4V implants were inserted bilaterally into the tibia of 110 rats. We compared two generations of cast Ti6Al4V implants (CAST 1st GEN, n = 22, and CAST 2nd GEN, n = 22) as well as cast 2nd GEN Ti6Al4V implants with calcium (CAST + CA, n = 22) and phosphorus (CAST + P, n = 22) ion implantation to standard machined Ti6Al4V implants (control, n = 22). After 4 and 12 weeks, maximal pull-out force and bone-to-implant contact rate (BIC) were measured and compared between all five groups. Results: There was no significant difference between all five groups after 4 weeks or 12 weeks with regard to pull-out force (p > 0.05, Kruskal Wallis test). Histomorphometric analysis showed no significant difference of BIC after 4 weeks (p > 0.05, Kruskal–Wallis test), whereas there was a trend towards a higher BIC in the CAST + P group (54.8% ± 15.2%), especially compared to the control group (38.6% ± 12.8%) after 12 weeks (p = 0.053, Kruskal–Wallis test). Conclusion: In this study, we found no indication of inferiority of Ti6Al4V implants cast with the optimized centrifugal precision casting technique of the second generation compared to standard Ti6Al4V implants. As the employed manufacturing process holds considerable economic potential, mainly due to a significantly decreased material demand per implant by casting near net-shape instead of milling away most of the starting ingot, its application in manufacturing uncemented implants seems promising. However, no significant advantages of calcium or phosphorus ion implantation could be observed in this study. Due to the promising results of ion implantation in previous in vitro and in vivo studies, further in vivo studies with different ion implantation conditions should be considered.


Author(s):  
Reham AlJasser ◽  
Sundus Bukhary ◽  
Mohammed AlSarhan ◽  
Dalal Alotaibi ◽  
Saleh AlOraini ◽  
...  

The aim of this in-vivo study was to evaluate/compare the clinical periodontal parameters in patients with true combined endo-perio lesions (EPL), treated with gutta-percha (GP) and mineral trioxide (MTA) as an obturation material alone and with addition of bone grafting in such lesions. 120 Saudi patients (mean age = 41yrs) diagnosed with true combined EPL participated in this study. Group I (control group, n = 30) was treated with conventional endodontic treatment using GP for obturation. Group II (n = 30) was treated with conventional endodontic treatment using MTA for obturation. Group III (n = 30) was treated with conventional endodontic treatment using GP for obturation + grafting procedure to fill the bony defect. Group IV (n = 30) was treated with conventional endodontic treatment using MTA for obturation + grafting procedure to fill the bony defect. Clinical parameters (Pocket depth (PD); Clinical attachment loss (CAL); keratinized tissue width (KTW); gingival phenotype (G.Ph.) and Cone Beam Computed Tomography Periapical Index (CBCTPAI)) were recorded and compared at baseline, 3, 6, 12 months’ interval. For the groups III and IV, CBCTPAI showed significant difference (p < 0.0001) with the other groups at 6 months and 1-year interval. The group with MTA + bone graft showed 76% and 90% patients with 0 score at 6 months and 1-year follow-up, respectively. Comparison of mean values of PD among study groups at 3 months, 6 months and 1 year showed significant difference at 3 months, whereas the mean PD values of subjects in GP + bone graft showed significantly higher PD values than other 3 groups (p = 0.025). Use of GP and MTA for root canal obturation along with periodontal therapy and bone augmentation helps in resolving complex endo-perio lesions. Bone grafting in addition to obturation with MTA was found to be the best treatment strategy in management of EPL cases and is recommended for clinicians who are treating EPL patients.


2015 ◽  
Vol 03 (02) ◽  
pp. 080-084
Author(s):  
Vijay Singh ◽  
Poonam Bogra ◽  
Saurabh Gupta ◽  
Navneet Kukreja ◽  
Neha Gupta

AbstractFracture resistance of endodontically treated teeth restored with post. Aims: This study aims to compare the fracture resistance of endodontically treated teeth restored with resin fiber and stainless steel post. Commercially available prefabricated resin fiber post(Dentsply Maillefer Easy Post), prefabricated stainless steel post(Coltene/Whaledent Parapost) were used. Methods and Material: Forty five maxillary central incisors were obturated and divided into 3 groups: Control Group (Group I) without any post (n = 15), Resin Fiber Post Group (Group II) (n = 15) and Stainless Steel Post Group (Group III) (n = 15). In all Groups except control group, post space was prepared; a post was cemented, and a core build-up was provided. All the specimens were subjected to compressive force under a universal testing machine until fracture. Statistical analysis used: The results were analyzed using the variable analysis test (ANOVA). Results: One-way analysis of variance revealed significant difference among test groups. The control group demonstrated highest fracture resistance (925.2183 N), followed by the resin fiber post group (486.7265 N) and stainless steel post group (423.539N). Conclusions: Teeth restored with resin fiber post showed higher fracture resistance values than prefabricated stainless steel post.


Biology ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 358
Author(s):  
Javier Aragoneses ◽  
Ana Suárez ◽  
Nansi López-Valverde ◽  
Francisco Martínez-Martínez ◽  
Juan Manuel Aragoneses

The aim of this study was to evaluate the effect of implant surface treatment with carboxyethylphosphonic acid and fibroblast growth factor 2 on the bone–implant interface during the osseointegration period in vivo using an animal model. The present research was carried out in six minipigs, in whose left tibia implants were inserted as follows: eight implants with a standard surface treatment, for the control group, and eight implants with a surface treatment of carboxyethylphosphonic acid and immobilization of FGF-2, for the test group. At 4 weeks after the insertion of the implants, the animals were sacrificed for the histomorphometric analysis of the samples. The means of the results for the implant–bone contact variable (BIC) were 46.39 ± 17.49% for the test group and 34.00 ± 9.92% for the control group; the difference was not statistically significant. For the corrected implant–bone contact variable (BICc), the mean value of the test group was 60.48 ± 18.11%, and that for the control group, 43.08 ± 10.77%; the difference was statistically significant (p-value = 0.035). The new bone formation (BV/TV) showed average results of 27.28 ± 3.88% for the test group and 26.63 ± 7.90% for the control group, meaning that the differences were not statistically significant (p-value = 0.839). Regarding the bone density at the interthread level (BAI/TA), the mean value of the test group was 32.27 ± 6.70%, and that of the control group was 32.91 ± 7.76%, with a p-value of 0.863, while for the peri-implant density (BAP/TA), the mean value of the test group was 44.96 ± 7.55%, and that for the control group was 44.80 ± 8.68%, without a significant difference between the groups. The current research only found a significant difference for the bone–implant contact at the cortical level; therefore, it could be considered that FGF-2 acts on the mineralization of bone tissue. The application of carboxyethylphosphonic acid on the surface of implants can be considered a promising alternative as a biomimetic coating for the immobilization of FGF-2. Despite no differences in the new bone formation around the implants or in the interthread or peri-implant bone density being detected, the biofunctionalization of the implant surface with FGF-2 accelerates the mineralization of the bone–implant interface at the cortical level, thereby reducing the osseointegration period.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Eman Gomaa El Saeed ◽  
Manal H Moussa ◽  
Gehad A Hammouda ◽  
Sahar M. M Omar

Abstract Background Repairing urinary bladder (UB) defect by enterocystoplasty remains the gold standard surgical bladder reconstruction procedure to increase the capacity and compliance of dysfunctional bladders. However, many complications were recorded. Aim of the work This work aimed to compare the consequences of reconstruction of urinary bladder defect using untreated small intestinal submucosal (SIS) matrix versus seeded and unseeded decellularized SIS matrix. Material and Methods Fifty female albino rats were used in this study. The animals were divided into three groups: Group I (Control) included ten adult rats from which ileal tissue was obtained. Group II included ten adult rats in which their UB defect was repaired by untreated cellular SIS. Group III included twenty adult rats that were subdivided into two subgroups, 10 rats each; Subgroup IIIA where rats had their UB defect repaired by acellular SIS and subgroup IIIb where rats had their UB defect repaired by acellular SIS seeded with adipose mesenchymal stem cells (AMSCs).Ten young rats were used for preparation of AMSCs. Morphometric and statistical analysis were also performed. Results In rats where UB defect was repaired by untreated cellular SIS, the graft area showed loss of epithelial polarity, presence of intraepithelial cysts and occasional extension of urothelium to the outer surface forming fistula. There were areas of metaplasia with the appearance PAS positive cells. In the lamina propria, there was areas of lymphocytic infiltration together with significant increase in the collagen fiber deposition (p &lt; 0.05). There was a significant decrease thickness of muscle layer as compared to control (p &lt; 0.05). In rats where UB defect was repaired by acellular SIS, urothelium in the graft area showed occasional squamous metaplasia and often the urothelium extended to the deeper layers forming Brunn's nest. There was minimal muscle regeneration in the graft area. However, in rats where UB defect was repaired by acellular SIS seeded with AMSCs, the urothelium in the graft area was nearly similar to control group with uniform urothelium thickness, minimal collagen fibers deposition and thick muscle layer that showed no significant difference from the control (p &gt; 0.05). Conclusion Acellular SIS seeded with AMSCs showed better results compared to non-seeded and cellular SIS in reconstructing urinary bladder defects.