scholarly journals Contrast-Enhanced Ultrasonography in the Diagnosis and Treatment Modulation of Breast Cancer

2021 ◽  
Vol 11 (2) ◽  
pp. 81
Author(s):  
Ioana Boca (Bene) ◽  
Sorin M. Dudea ◽  
Anca I. Ciurea

The aim of this paper is to highlight the role of contrast-enhanced ultrasound in breast cancer in terms of diagnosis, staging and follow-up of the post-treatment response. Contrast-enhanced ultrasound (CEUS) is successfully used to diagnose multiple pathologies and has also clinical relevance in breast cancer. CEUS has high accuracy in differentiating benign from malignant lesions by analyzing the enhancement characteristics and calculating the time-intensity curve’s quantitative parameters. It also has a significant role in axillary staging, especially when the lymph nodes are not suspicious on clinical examination and have a normal appearance on gray-scale ultrasound. The most significant clinical impact consists of predicting the response to neoadjuvant chemotherapy, which offers the possibility of adjusting the therapy by dynamically evaluating the patient. CEUS is a high-performance, feasible, non-irradiating, accessible, easy-to-implement imaging method and has proven to be a valuable addition to breast ultrasound.

2021 ◽  
Vol 49 (5) ◽  
pp. 030006052110106
Author(s):  
Shanhong Lin ◽  
Yong Cao ◽  
Libin Chen ◽  
Mei Chen ◽  
Shengmin Zhang ◽  
...  

We herein present a rare case of breast fibromatosis, the contrast-enhanced ultrasonography (CEUS) findings of which we believe have never been described. The high similarity between the clinical and imaging manifestations of breast cancer makes its differential diagnosis difficult. In this report, we describe the CEUS findings of a less common type of fibromatosis, discuss the potential value of CEUS to differentiate it from malignant breast lesions, and briefly review the literature.


2018 ◽  
Vol 105 (5) ◽  
pp. 378-387 ◽  
Author(s):  
Giulia Bicchierai ◽  
Jacopo Nori ◽  
Diego De Benedetto ◽  
Cecilia Boeri ◽  
Ermanno Vanzi ◽  
...  

PurposeTo evaluate the role of contrast-enhanced spectral mammography (CESM) in the post biopsy management of breast lesions classified as lesions of uncertain malignant potential (B3) by core needle biopsy and vacuum-assisted biopsy (VAB).MethodsThe local ethics committee approved this retrospective study and for this type of study formal consent is not required. A total of 42 B3 lesions in 40 women aged 41–77 years were included in our study. All patients underwent CESM 2–3 weeks after the biopsy procedure and surgical excision was subsequently performed within 60 days of the CESM procedure. Three radiologists reviewed the images independently. The results were then compared with histologic findings.ResultsThe sensitivity, specificity, and positive and negative predictive values for confirmed demonstration of malignancy at CESM were 33.3%, 87.2%, 16.7%, and 94.4% for reader 1; 66.7%, 76.9%, 18.2%, and 96.7% for reader 2; 66.7%, 74.4%, 16.7%, and 96.7% for reader 3. Overall agreement on detection of malignant lesions using CESM among readers ranged from moderate to substantial (κ = .451–.696), for categorization of BPE from moderate to substantial (κ = .562–.711), and for evaluation of lesion intensity enhancement from fair to moderate (κ = .346–.459).ConclusionIn cases of Breast Imaging Reporting and Data System (BI-RADS) 1, BI-RADS 2, or BI-RADS 3 results at CESM, follow-up or VAB rather than surgical biopsy might be performed.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ernst Michael Jung ◽  
Friedrich Jung ◽  
Christian Stroszczynski ◽  
Isabel Wiesinger

AbstractThe aim of this present clinical pilot study is the display of typical perfusion results in patients with solid, non-cystic breast lesions. The lesions were characterized using contrast enhanced ultrasound (CEUS) with (i) time intensity curve analyses (TIC) and (ii) parametric color maps. The 24 asymptomatic patients included were genetically tested for having an elevated risk for breast cancer. At a center of early detection of familial ovary and breast cancer, those patients received annual MRI and grey-scale ultrasound. If lesions remained unclear or appeared even suspicious, those patients also received CEUS. CEUS was performed after intravenous application of sulfur hexafluoride microbubbles. Digital DICOM cine loops were continuously stored for one minute in PACS (picture archiving and communication system). Perfusion images and TIC analyses were calculated off-line with external perfusion software (VueBox). The lesion diameter ranged between 7 and 15 mm (mean 11 ± 3 mm). Five hypoechoic irregular lesions were scars, 6 lesions were benign and 12 lesions were highly suspicious for breast cancer with irregular enhancement at the margins and a partial wash out. In those 12 cases, histopathology confirmed breast cancer. All the suspicious lesions were correctly identified visually. For the perfusion analysis only Peak Enhancement (PE) and Area Under the Curve (AUC) added more information for correctly identifying the lesions. Typical for benign lesions is a prolonged contrast agent enhancement with lower PE and prolonged wash out, while scars are characterized typically by a reduced enhancement in the center. No differences (p = 0.428) were found in PE in the center of benign lesions (64.2 ± 28.9 dB), malignant lesions (88.1 ± 93.6 dB) and a scar (40.0 ± 17.0 dB). No significant differences (p = 0.174) were found for PE values at the margin of benign lesions (96.4 ± 144.9 dB), malignant lesions (54.3 ± 86.2 dB) or scar tissue (203.8 ± 218.9 dB). Significant differences (p < 0.001) were found in PE of the surrounding tissue when comparing benign lesions (33.6 ± 25.2 dB) to malignant lesions (15.7 ± 36.3 dB) and scars (277.2 ± 199.9 dB). No differences (p = 0.821) were found in AUC in the center of benign lesions (391.3 ± 213.7), malignant lesions (314.7 ± 643.9) and a scar (213.1 ± 124.5). No differences (p = 0.601) were found in AUC values of the margin of benign lesions (313.3 ± 372.8), malignant lesions (272.6 ± 566.4) or scar tissue (695.0 ± 360.6). Significant differences (p < 0.01) were found in AUC of the surrounding tissue for benign lesions (151.7 ± 127.8), malignant lesions (177.9 ± 1345.6) and scars (1091 ± 693.3). There were no differences in perfusion evaluation for mean transit time (mTT), rise time (RT) and time to peak (TTP) when comparing the center to the margins and the surrounding tissue. The CEUS perfusion parameters PE and AUC allow a very good assessment of the risk of malignant breast lesions and thus a downgrading of BI-RADS 4 lesions. The use of the external perfusion software (VueBox, Bracco, Milan, Italy) did not lead to any further improvement in the diagnosis of suspicious breast lesions and does appears not to have any additional diagnostic value in breast lesions.


2012 ◽  
Vol 18 (15) ◽  
pp. 2214-2222 ◽  
Author(s):  
Mariarosaria Giannoni ◽  
Michele Citone ◽  
Michele Rossini ◽  
Francesco Speziale ◽  
Vincenzo David

2018 ◽  
Vol 17 (2) ◽  
pp. e1492
Author(s):  
M.D. Sanchez Gallego ◽  
E. Sanz Mayayo ◽  
V. Gómez Dos Santos ◽  
R. Rodríguez-Patrón Rodriguez ◽  
J. Lorca Álvaro ◽  
...  