scholarly journals A Novel Glass Polyalkenoate Cement for Fixation and Stabilisation of the Ribcage, Post Sternotomy Surgery: An ex-Vivo Study

2013 ◽  
Vol 4 (4) ◽  
pp. 329-357 ◽  
Author(s):  
Adel Alhalawani ◽  
Declan Curran ◽  
Belinda Pingguan-Murphy ◽  
Daniel Boyd ◽  
Mark Towler
2021 ◽  
Author(s):  
Adel M.F. Alhalawani ◽  
Declan J. Curran ◽  
Belinda Pingguan-Murphy ◽  
Daniel Boyd ◽  
Mark R. Towler

This study investigates the use of gallium (Ga) based glass polyalkenoate cements (GPCs) as a possible alternative adhesive in sternal fixation, post sternotomy surgery. The glass series consists of a Control (CaO–ZnO–SiO2), and LGa-1 and LGa-2 which contain Ga at the expense of zinc (Zn) in 0.08 mol% increments. The additions of Ga resulted in increased working time (75 s to 137 s) and setting time (113 to 254 s). Fourier Transform Infrared (FTIR) analysis indicated that this was a direct result of increased unreacted poly(acrylic acid) (PAA) and the reduction of crosslink formation during cement maturation. LGa samples (0.16 wt % Ga) resulted in an altered ion release profile, particularly for 30 days analysis, with maximum Ca2+, Zn2+, Si4+ and Ga3+ ions released into the distilled water. The additions of Ga resulted in increased roughness and decreased contact angles during cement maturation. The presence of Ga has a positive effect on the compressive strength of the samples with strengths increasing over 10 MPa at 7 days analysis compared to the 1 day results. The additions of Ga had relatively no effect on the flexural strength. Tensile testing of bovine sterna proved that the LGa samples (0.16 wt % Ga) are comparable to the Control samples.


2021 ◽  
Author(s):  
Adel M.F. Alhalawani ◽  
Declan J. Curran ◽  
Belinda Pingguan-Murphy ◽  
Daniel Boyd ◽  
Mark R. Towler

This study investigates the use of gallium (Ga) based glass polyalkenoate cements (GPCs) as a possible alternative adhesive in sternal fixation, post sternotomy surgery. The glass series consists of a Control (CaO–ZnO–SiO2), and LGa-1 and LGa-2 which contain Ga at the expense of zinc (Zn) in 0.08 mol% increments. The additions of Ga resulted in increased working time (75 s to 137 s) and setting time (113 to 254 s). Fourier Transform Infrared (FTIR) analysis indicated that this was a direct result of increased unreacted poly(acrylic acid) (PAA) and the reduction of crosslink formation during cement maturation. LGa samples (0.16 wt % Ga) resulted in an altered ion release profile, particularly for 30 days analysis, with maximum Ca2+, Zn2+, Si4+ and Ga3+ ions released into the distilled water. The additions of Ga resulted in increased roughness and decreased contact angles during cement maturation. The presence of Ga has a positive effect on the compressive strength of the samples with strengths increasing over 10 MPa at 7 days analysis compared to the 1 day results. The additions of Ga had relatively no effect on the flexural strength. Tensile testing of bovine sterna proved that the LGa samples (0.16 wt % Ga) are comparable to the Control samples.


2020 ◽  
Author(s):  
Rafael Heiss ◽  
Frank W. Roemer ◽  
Christoph Lutter ◽  
Rolf Janka ◽  
Volker Schöffl ◽  
...  

2014 ◽  
Author(s):  
Klaus Engelke ◽  
Nicolas Bouler ◽  
Oleg Museyko Fuerst ◽  
Sebastien Parratte ◽  
Thomas Fuerst ◽  
...  

2020 ◽  
Vol 26 (6) ◽  
pp. 667-670
Author(s):  
Thomas Larrew ◽  
Mohammed Alshareef ◽  
Robert F. Murphy ◽  
Ramin Eskandari ◽  
Libby Kosnik Infinger

OBJECTIVEAlthough the advent of magnetic growing rod technology for scoliosis has provided a means to bypass multiple hardware lengthening operations, it is important to be aware that many of these same patients have a codiagnosis of hydrocephalus with magnet-sensitive programmable ventricular shunts. As the magnetic distraction of scoliosis rods has not previously been described to affect the shunt valve setting, the authors conducted an investigation to characterize the interaction between the two devices.METHODSIn this ex vivo study, the authors carried out 360 encounters between four different shunt valve types at varying distances from the magnetic external remote control (ERC) used to distract the growing rods. Valve settings were examined before and after every interaction with the remote control to determine if there was a change in the setting.RESULTSThe Medtronic Strata and Codman Hakim valves were found to have setting changes at distances of 3 and 6 inches but not at 12 inches. The Aesculap proGAV and Codman Certas valves, typically described as MRI-resistant, did not have any setting changes due to the magnetic ERC regardless of distance.CONCLUSIONSAlthough it is not necessary to check a shunt valve after every magnetic distraction of scoliosis growing rods, if there is concern that the magnetic ERC may have been within 12 inches (30 cm) of a programmable ventricular shunt valve, the valve should be checked at the bedside with a programmer or with a skull radiograph along with postdistraction scoliosis radiographs.


2016 ◽  
Vol 16 (12) ◽  
pp. 1615-1621 ◽  
Author(s):  
Erik Andrade-Jorge ◽  
Marycarmen Godínez-Victoria ◽  
Luvia Enid Sánchez-Torres ◽  
Luis Humberto Fabila-Castillo ◽  
José G. Trujillo-Ferrara

Sign in / Sign up

Export Citation Format

Share Document