scholarly journals Comparison of the Efficacy of Different Techniques for the Removal of Root Canal Filling Material in Artificial Teeth: A Micro-Computed Tomography Study

2019 ◽  
Vol 8 (7) ◽  
pp. 984
Author(s):  
Tuan Anh Nguyen ◽  
Yaelim Kim ◽  
Euiseong Kim ◽  
Su-Jung Shin ◽  
Sunil Kim

This study aimed to assess the efficacy of canal filling material removal using three different techniques after filling with a Gutta–Percha (GP) cone and calcium silicate-based sealer, by measuring the percentage of volume debris of GP and sealer remaining intracanal with micro computed tomography (micro-CT). The filling material was removed from 30 plastic teeth by a nickel–titanium (Ni–Ti) rotary retreatment system. Final irrigation was performed with 2 mL of saline and 10 specimens were randomly allocated to a conventional group. In the passive ultrasonic irrigation (PUI) group, ultrasonic irrigation was added to the conventional group (n = 10). In the Gentlefile Brush (GF Brush) group, irrigation with GF Brush was added to the conventional group (n = 10). Remaining filling material was measured using micro-CT imaging analysis. The total mean volume of residual filling material after retreatment in the conventional group, PUI group and GF Brush group were 4.84896 mm3, 0.80702 mm3, and 0.05248 mm3, respectively. The percentage of filling material remaining intracanal was 6.76% in the conventional group, 1.12% in the PUI group and 0.07% in the GF Brush group. This study shows that the cleaning effect of the GF Brush system is superior to those of Ni–Ti retreatment files and the PUI system in the apical area.

2019 ◽  
Vol 7 (1) ◽  
pp. 2 ◽  
Author(s):  
Marc Krikor Kaloustian ◽  
Walid Nehme ◽  
Claire El Hachem ◽  
Carla Zogheib ◽  
Nabil Ghosn ◽  
...  

We assessed the efficiency of two shaping file systems and two passive ultrasonic irrigation (PUI) devices for removing filling material during retreatment. The mesial canals from 44 extracted mandibular molars were prepared and obturated. The teeth were randomly divided into two groups, and then one group was retreated with Reciproc R25 (VDW, Munich, Germany) (n = 44) and the other group was retreated with 2Shape (TS, Micro Mega, Besançon, France) (n = 44). A micro-computed tomography (CT) scan was taken before and after the retreatment to assess the volume of the filling material remnants. The teeth were then randomly divided into four groups to test two different PUI devices: Irrisafe (Satelec Acteon Group, Merignac, France) and Endo Ultra (Vista Dental Products, Racine, WI, USA). The teeth in Group A were retreated with 2Shape to test the Endo Ultra (n = 22) device, the teeth in Group B were retreated with 2Shape in order to test the Irrisafe (n = 22) device, the teeth in Group C were retreated with Reciproc to test the Endo Ultra (n = 22) device, and Group D was retreated with Reciproc to test the Irrisafe (n = 22) device. A third micro-CT scan was taken after the retreatment to test the PUIs. The percentage of Gutta-Percha (GP) and sealer removed was 94.75% for TS2 (p < 0.001) and 89.3% for R25 (p < 0.001). The PUI significantly enhanced the removal of the filling material by 0.76% for Group A (p < 0.001), 1.47% for Group B (p < 0.001), 2.61% for Group C (p < 0.001), and by 1.66% for Group D (p < 0.001). 2Shape was more effective at removing the GP and sealer during retreatment (p = 0.018). The supplementary approach with PUI significantly improved filling material removal, with no statistical difference between the four groups (p = 0.106).


2013 ◽  
Vol 24 (4) ◽  
pp. 367-370 ◽  
Author(s):  
Joao Manoel Silva-Filho ◽  
Aline Evangelista Souza-Gabriel ◽  
Graziela Bianchi Leoni ◽  
Samuel Henrique Camara De-Bem ◽  
Edson Alfredo ◽  
...  

This study used micro-computed tomography (micro-CT) to evaluate the fit of the master gutta-percha cone at time of cone fit, gutta-percha volume in the filling material, and the filling material volume in relation to the canal at the apical limit of the working length. Root canals of 20 maxillary central incisors were prepared with rotary instruments and distributed into two groups (n=10). The gutta-percha cone tip was either plasticized (apical thermal impression technique - ATI) or not (conventional technique - CT), and its apical fit was checked. The apical 1 mm of working length was examined with a micro-CT, canals were filled with gutta-percha and sealer, and new micro-CT scans were obtained. In CT, gutta-percha filled 35.83 ± 15.05% of the canal at cone selection and 38.72 ± 11.64% after filling. In ATI, these values were 23.14 ± 7.74% and 26.98 ± 20.40%, respectively. Gutta-percha volume in the filling material, and filling material volume in relation to the canal were, respectively, 61.28 ± 11.64% and 87.76 ± 9.98% for CT, and 73.00 ± 20.41% and 89.96 ± 9.08% for ATI. No significant difference was found between cone selection and after canal filling, for either CT (p=0.593) or ATI (p=0.4975). The techniques did not differ significantly with respect to gutta-percha volume in the filling material (p=0.132) and filling material volume in relation to the canal (p=0.612). An ideal fit of the master gutta-percha cone at working length was not achieved regardless of the cone selection technique, and the material-filled area was similar for both techniques.


2019 ◽  
Vol 890 ◽  
pp. 275-282
Author(s):  
Isabel Vasconcelos ◽  
Mário Rito Pereira ◽  
António Ginjeira ◽  
Margarida C. Franco ◽  
Pedro Morouço ◽  
...  

This pilot study aims to define a protocol for optimizing the micro-computed tomography (micro-CT) settings to evaluate in the future research the root canal filling in oval shaped canals. Thirty distal canals of mandibular molars were used. After preparation of the canals, the roots were randomly divided into five groups. The canals were filled with two types of sealers (Endosequence BC Sealer or AH Plus) and two types of gutta percha (Protaper Next cones and Endosequence BC cones), using thermal obturation in comparison with a single cone obturation technique. Each specimen was scanned three times using a micro-CT device at a resolution of 30,1 μm. The first scan was done for selecting the specimen according the inclusion criteria, the second one post-instrumentation and the last micro-CT scan after obturation the specimens. For the present study, the images were only evaluated with qualitative criteria and the settings for acquisition, reconstruction and analysis of micro-CT images were tested.


2021 ◽  
Vol 15 (4) ◽  
pp. 273-278
Author(s):  
Esin Özlek ◽  
Hüseyin Gündüz

Background. This study aimed to examine the retreatment efficiency of four NiTi rotary file systems with micro-computed tomography (micro-CT). Methods. Forty premolar teeth were shaped up to F2 using the ProTaper Universal rotary file system and obturated with MTA Fillapex. The root canals were scanned with micro-CT to evaluate the volume of root canal filling before retreatment. The samples were randomly divided into four groups according to the file system used to remove root canal filling material (n=10): ProTaper Universal Retreatment, ProTaper NEXT, EdgeFile XR, and EdgeFile® X3 NiTi system. All the samples were scanned with a micro-CT device for the second time to evaluate the amount of residual filling material in the root canals. The percentages of filling material removed from root canals were calculated. Additionally, the time spent on the removal of the root canal filling material was recorded. The data were analyzed using the Shapiro-Wilk and Kruskal-Wallis tests. Results. There were no significant differences between the groups in the percentage of root canal filling material removal. However, a statistically significant difference was found between the groups in the time required to reach the apex and remove the entire filling material. The time required to remove the root canal filling material was higher in the EdgeFile® X3 group. Conclusion. NiTi files manufactured for root canal preparation can be used effectively and safely to remove root canal filling materials. EdgeFile XR produced for retreatment can be used as an alternative to ProTaper Universal Retreatment files.


Author(s):  
Lincoln de Campos Fruchi

Objectives: The purpose of this study was to evaluate the efficacy of steps, isolated or in cumulative means, in the endodontic retreatment of curved canals. Methodology: Forty mesial roots of mandibular molars were divided into two groups. In the group 1 the filling removal was done with NiTi reciprocating M-wire and NiTi control memory wire rotary instruments followed by a passive ultrasonic irrigation solution agitation. In the group 2, the initial filling removal was done with NiTi reciprocating M-wire and conventional NiTi wire rotary instruments followed by a rotary plastic instrument for irrigation solution agitation. The results were analyzed through micro-computed tomography. Results: The filling material was not completely removed for both groups. All steps did not statically differ between groups regarding to the filling removal. In the intragroup analyses, the results differed in some levels, mainly in the apical level, but did not statistically differ in all the different levels after each step. A statistical significant increase (P<.05), for both groups, in the volume of filling material in the isthmus was observed. Conclusions: None of the protocols completely removed the filling material. The better results were found for the apical level and after passive ultrasonic irrigation. Vertical warm condensation filling technique enhanced the volume of filling material in the root canal system including the isthmus. Clinical relevance: the control memory NiTi instruments could be considered a good choice for use as an additional step in the procedure of filling removal from curved mesial root canals.


2015 ◽  
Vol 26 (6) ◽  
pp. 612-618 ◽  
Author(s):  
Ricardo Abreu da Rosa ◽  
Manuela Favarin Santini ◽  
Bruno Cavalini Cavenago ◽  
Jefferson Ricardo Pereira ◽  
Marco Antônio Húngaro Duarte ◽  
...  

The aim of this study was to quantify the residual filling material after filling removal, re-preparation with rotary or reciprocating files and passive ultrasonic irrigation (PUI). Twenty maxillary molars were prepared using ProTaper instruments up to F1. The teeth were filled with AH Plus and ProTaper gutta-percha points using the single-cone technique. Thereafter, the specimens were scanned using a micro-computed tomography system (Micro-CT #1). Then, the root canal filling was removed using ProTaper Retreatment files, and a new scan was performed (Micro-CT #2). The specimens were divided into two groups according to the instrument used for re-preparation: ProTaper rotary or WaveOne reciprocating files (Micro-CT #3). Finally, PUI was performed, and a new micro-CT scan was performed (Micro-CT #4). Intragroup and intergroup analyses were performed using Friedman and Dunn's post hoc test and the Kruskal-Wallis and Dunn post hoc tests, respectively. Palatal canal presented the highest volume of residual filling material in all stages of endodontic retreatment (p<0.05). The main reduction of filling volume was achieved after using ProTaper Retreament (p<0.05). The amount of remaining filling material after using ProTaper Retreatment was similar to that achieved with rotary and reciprocating files and after PUI (p>0.05). Rotary and reciprocating files achieved similar removal of the root canal filling (p>0.05). The greatest reduction in filling material was achieved after using ProTaper Retreatment files. Rotary and reciprocating instruments and PUI did not improve the removal of root canal filling materials.


2013 ◽  
Vol 24 (6) ◽  
pp. 585-590 ◽  
Author(s):  
Gabriela Guardiola Muller ◽  
Anielle Pinheiro Schonhofen ◽  
Patricia Maria Poli Kopper Mora ◽  
Fabiana Soares Grecca ◽  
Marcus Vinicius Reis So ◽  
...  

The aim of this study was to investigate whether a final rinse with Endosolv R® solvent and ultrasound resulted in cleaner root canal walls during endodontic retreatment. A total of 56 extracted premolar teeth were manually instrumented using a step-back flare technique and filled with gutta-percha and AH Plus sealer. After 9 months, the canals were retreated by removing the gutta-percha and sealer with ProTaper Universal Retreatment and rotary preparation with ProTaper Universal System up to an F5 file. As a final step, the teeth were randomly divided in 4 groups (n=14) and were subjected to passive ultrasonic irrigation (PUI) with either Endosolv R or distilled water. In the control groups, the irrigants were left undisturbed. Roots were cleaved and examined under scanning electron microscopy (SEM), and the amount of filling remnants on the canal walls was assessed by two calibrated examiners in a blinded fashion. Data were analyzed by the Kruskal-Wallis test and the Student-Newman-Keuls post hoc test (α=0.05). All groups presented filling debris in the three root canal thirds after retreatment. There were no significant differences between the groups or among the root canal thirds within each group (p>0.05). PUI with Endosolv R was not effective in the removal of filling debris from root canal walls.


2021 ◽  
Vol 10 (15) ◽  
pp. e444101523301
Author(s):  
Christianne Velozo ◽  
Hugo Dantas ◽  
Basílio Rodrigues Vieira ◽  
Frederico Barbosa de Sousa ◽  
Victor Felipe Farias do Prado ◽  
...  

The present study aimed to evaluate adaptation of the single gutta-percha cone on root canal walls prepared with the two systems, the XP-endo Shaper (XPS; FKG Dentaire, La Chaux-de-Fonds, Switzerland) and ProTaper Next systems (PTN; Dentsply Sirona, Ballaigues, Switzerland) by using micro-computed tomography (micro-CT) technology. Twenty long oval-shaped canals in mandibular incisors were scanned by micro-CT (Skyscan 1172; Bruker microCT, Kontich, Belgium). Two groups were divided into (n = 10) according to the canal preparation protocol: XPS group with an extra 45 s of instrumentation and PTN group. A gutta percha cone, with respect to the protocol used for each group (size 40, .04 taper, XPS and size 40, .06 taper, PTN) was adapted to the canal at the working length of all the samples, and all root canals were filled, using the single-cone technique. The mean values for volume of voids and percentage relative to the mentioned space were correspondingly higher in XPS group than they were PTN group, mean values for volume of voids (3.61 mm3 - 1.92 mm3) and for percentage of voids (39.25% - 23.28%), respectively, significant differences were recorded (p < 0.05) between the two groups (XPS and PTN, Student’s-t test for homogenous variances and Mann–Whitney test). The canals prepared with XPS, in the procedure performed with an extra 45 s of instrumentation, showed a higher volume of voids than those prepared with the PTN system, in obturation of the root canal with the single cone technique.


2020 ◽  
Vol 9 (6) ◽  
pp. 1989 ◽  
Author(s):  
Tarek-Fahed Alakabani ◽  
Vicente Faus-Llácer ◽  
Ignacio Faus-Matoses ◽  
Celia Ruiz-Sánchez ◽  
Álvaro Zubizarreta-Macho ◽  
...  

The aim of this study is to analyze and compare the efficacy of three non-surgical endodontic retreatment techniques in removing a carrier-based root canal filling material from straight root canal systems. The study was performed on 99 single-rooted extracted teeth using the ProTaper Gold endodontic rotary system up to the F2 file (Dentsply Maillefer, Baillagues, Switzerland), which were sealed with GuttaCore (Dentsply Maillefer, Ballaigues, Switzerland) and AH plus epoxy resin sealer (Dentsply DeTrey, Konstanz, Germany) and randomly assigned to the following non-surgical retreatment techniques: ProTaper Retreatment endodontic rotary instruments (D1–D3 files, Dentsply Maillefer, Ballaigues, Switzerland; n = 33, PTR), Reciproc Blue endodontic reciprocating instrument (R50, VDW, Munich, Germany; n = 33, RCB50), and a combined root canal retreatment technique between Gates-Glidden drills (sizes #3 and #2, Dentsply Maillefer, Ballaigues, Switzerland) and Hedstrom files (file size 35, 30, and 25, Dentsply Maillefer, Ballaigues, Switzerland; n = 33; H-GG). All of the teeth were submitted twice to a micro-computed tomography (micro-CT) scan, before and after non-surgical endodontic retreatment procedures. The volume of root canal filling material (mm3), volume of remaining root canal filling material (mm3), non-surgical endodontic retreatment working time (min), proportion of remaining root canal filling material (%), and efficacy of root canal filling material removal between the non-surgical endodontic retreatment techniques were analyzed using ANOVA one-way statistical analysis. Statistically significant differences were observed between the proportions of remaining root canal filling material of PTR and H-GG (p = 0.018), between the non-surgical endodontic retreatment working times (min; p < 0.001), and between the efficacies of root canal filling material removal by the non-surgical endodontic retreatment techniques (p = 0.009). However, the non-surgical endodontic retreatment systems allow for similar carrier-based root canal filling material removal.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Inês Ferreira ◽  
Pedro S. Babo ◽  
Ana Cristina Braga ◽  
Maria Ascensão Lopes ◽  
Manuela E. Gomes ◽  
...  

AbstractThis study aimed to compare the efficacy of XP-endo Finisher R and IrriSafe, with a solvent mixture of Methyl ethyl ketone/Tetrachloroethylene (MEK/TCE), in the removal of root filling residues. Twenty-four human mandibular incisors were pair-matched by micro-computed tomography according to volume and aspect ratio. After retreatment, specimens were allocated to two experimental groups (n = 12), according to the supplementary instrument used. The volume of residual filling material after each irrigating step and the time for retreatment was calculated. Statistical analyses were carried out using Mann–Whitney test, with a significance level of 5%. The volume of initial root canal filling material between the groups was similar (p > 0.05). With the final irrigation protocol (NaOCl and EDTA) the volume of the filling remnants decreased significantly (p < 0.05) with no differences between IrriSafe or XP-endo Finisher R (p > 0.05). The additional solvent mixture MEK/TCE increased the efficiency of filling materials reduction, regardless of the agitating instruments employed, IrriSafe or XP-endo Finisher R (p < 0.05). There was no difference between the two groups regarding the time (p = 0.149). Both supplementary instruments were effective in the reduction of filling remnants. The additional step with a solvent mixture of MEK/TCE enabled a total recovery of patency and the achievement of cleaner canals, independently of the agitation instrument.


Sign in / Sign up

Export Citation Format

Share Document