scholarly journals Negligible Correlation between Radiographic Measurements and Clinical Outcomes in Patients Following Primary Reverse Total Shoulder Arthroplasty

2021 ◽  
Vol 10 (4) ◽  
pp. 809
Author(s):  
Daniel P. Berthold ◽  
Daichi Morikawa ◽  
Lukas N. Muench ◽  
Joshua B. Baldino ◽  
Mark P. Cote ◽  
...  

Previous attempts to measure lateralization, distalization or inclination after reverse total shoulder arthroplasty (rTSA) and to correlate them with clinical outcomes have been made in the past years. However, this is considered to be too demanding and challenging for daily clinical practice. Additionally, the reported findings were obtained from heterogeneous rTSA cohorts using 145° and 155° designs and are limited in external validity. The purpose of this study was to investigate the prognostic preoperative and postoperative radiographic factors affecting clinical outcomes in patients following rTSA using a 135° prosthesis design. In a multi-center design, patients undergoing primary rTSA using a 135° design were included. Radiographic analysis included center of rotation (COR), acromiohumeral distance (AHD), lateral humeral offset (LHO), distalization shoulder angle (DSA), lateralization shoulder angle (LSA), critical shoulder angle (CSA), and glenoid and baseplate inclination. Radiographic measurements were correlated to clinical and functional outcomes, including the American Shoulder and Elbow Surgeons (ASES), Simple Shoulder Test (STT), Single Assessment Numeric Evaluation (SANE), and Visual Analogue Scale (VAS) score, active forward elevation (AFE), external rotation (AER), and abduction (AABD), at a minimum 2-year follow-up. There was a significant correlation between both DSA (r = 0.299; p = 0.020) and LSA (r = −0.276; p = 0.033) and the degree of AFE at final follow-up. However, no correlation between DSA (r = 0.133; p = 0.317) and LSA (r = −0.096; p = 0.471) and AER was observed. Postoperative AHD demonstrated a significant correlation with final AFE (r = 0.398; p = 0.002) and SST (r = 0.293; p = 0.025). Further, postoperative LHO showed a significant correlation with ASES (r = −0.281; p = 0.030) and LSA showed a significant correlation with ASES (r = −0.327; p = 0.011), SANE (r = −0.308, p = 0.012), SST (r = −0.410; p = 0.001), and VAS (r = 0.272; p = 0.034) at terminal follow-up. All other correlations were found to be non-significant (p > 0.05, respectively). Negligible correlations between pre- and postoperative radiographic measurements and clinical outcomes following primary rTSA using a 135° prosthesis design were demonstrated; however, these observations are of limited predictive value for outcomes following rTSA. Subsequently, there remains a debate regarding the ideal placement of the components during rTSA to most sufficiently restore active ROM while minimizing complications such as component loosening and scapular notching. Additionally, as the data from this study show, there is still a considerable lack of data in assessing radiographic prosthesis positioning in correlation to clinical outcomes. As such, the importance of radiographic measurements and their correlation with clinical and functional outcomes following rTSA may be limited.

2021 ◽  
Vol 24 (3) ◽  
pp. 125-134
Author(s):  
Kirtan Tankshali ◽  
Dong-Whan Suh ◽  
Jong-Hun Ji ◽  
Chang-Yeon Kim

Background: To evaluate clinical and radiological outcomes of bony increased offset-reverse total shoulder arthroplasty (BIO-RSA) in the Asian population at mid-term follow-up.Methods: From June 2012 to August 2017 at a single center, 43 patients underwent BIO-RSA, and 38 patients with a minimum of 2 years of follow-up were enrolled. We evaluated the preoperative and postoperative clinical outcomes, radiological outcomes (notching and loosening), and complications of BIO-RSA at the last follow-up. In addition, we divided these patients into notching and not-notching groups and compared the demographics, preoperative, and postoperative characteristics of patients between the two groups.Results: Visual analog scale, American Shoulder and Elbow Surgeons, University of California-Los Angeles, and Simple Shoulder Test scores improved significantly from preoperative (average: 5, 39.43, 16.22, 3.94) to postoperative (average: 1.71, 78.91, 28.34, 7.8; p<0.05) outcomes. All range of motion except internal rotation improved significantly at the final follow-up (p<0.05), and the bone graft was well-incorporated with the native glenoid in all patients (100%). However, scapular notching was observed in 20/38 patients (53%). In the comparison between notching and not-notching groups (18 vs. 20 patients), there were no significant differences in demographics, radiological parameters, and clinical outcomes except acromion-greater tuberosity (AT) distance (p=0.003). Intraoperative complications were three metaphyseal fractures and one inferior screw malposition. Postoperative complications included one heterotopic ossification, one scapula neck stress fracture, one humeral stem loosening, and one late infection.Conclusions: BIO-RSA resulted in improved clinical outcomes at mid-term follow-up in the Asian population. Although better cosmesis and advantages of glenoid lateralization were observed, we observed higher rates of scapular notching compared to previously reported rates in BIO-RSA studies. In addition, adequate glenoid lateralization with appropriate humeral lengthening (AT distance) might reduce scapular notching.


2018 ◽  
Vol 100-B (6) ◽  
pp. 761-766 ◽  
Author(s):  
M. Holschen ◽  
M-K. Siemes ◽  
K-A. Witt ◽  
J. Steinbeck

Aims The reasons for failure of a hemirthroplasty (HA) when used to treat a proximal humeral fracture include displaced or necrotic tuberosities, insufficient metaphyseal bone-stock, and rotator cuff tears. Reverse total shoulder arthroplasty (rTSA) is often the only remaining form of treatment in these patients. The aim of this study was to evaluate the clinical outcome after conversions from a failed HA to rTSA. Material and Methods A total of 35 patients, in whom a HA, as treatment for a fracture of the proximal humerus, had failed, underwent conversion to a rTSA. A total of 28 were available for follow-up at a mean of 61 months (37 to 91), having been initially reviewed at a mean of 20 months (12 to 36) postoperatively. Having a convertible design, the humeral stem could be preserved in nine patients. The stem was removed in the other 19 patients and a conventional rTSA was implanted. At final follow-up, patients were assessed using the American Shoulder and Elbow Surgeons (ASES) score, the Constant Score, and plain radiographs. Results At final follow-up, the mean ASES was 59 (25 to 97) and the mean adjusted Constant Score was 63% (23% to 109%). Both improved significantly (p < 0.001). The mean forward flexion was 104° (50° to 155°) and mean abduction was 98° (60° to 140°). Nine patients (32%) had a complication; two had an infection and instability, respectively; three had a scapular fracture; and one patient each had delayed wound healing and symptomatic loosening. If implants could be converted to a rTSA without removal of the stem, the operating time was shorter (82 minutes versus 102 minutes; p = 0.018). Conclusion After failure of a HA in the treatment of a proximal humeral fracture, conversion to a rTSA may achieve pain relief and improved shoulder function. The complication rate is considerable. Cite this article: Bone Joint J 2018;100-B:761–6.


2019 ◽  
Vol 12 (10) ◽  
pp. e230212 ◽  
Author(s):  
Alexander Wendling ◽  
Matthew L Vopat ◽  
Shang-You Yang ◽  
Bradley Saunders

A man in his mid-80s presented with bilateral posterior fracture dislocations of the humerus after suffering a seizure. He had Parskinson’s disease and lived with his wife at home. His left shoulder was not felt to be reconstructable. The initial treatment plan was to perform reverse total shoulder arthroplasty (rTSA) on the left and non-operatively reduce his right shoulder. A left rTSA was performed, but his right shoulder was unstable due to a glenoid fracture and soft tissue instability. In order to preserve the patient’s quality of life, a right rTSA was performed 4 days later. In the follow-up period, the patient was able to regain enough pain-free range of motion on activities of daily living. The patient died from complications of Parkinson’s disease 10 months postoperatively.