scholarly journals High Mutational Heterogeneity, and New Mutations in the Human Coagulation Factor V Gene. Future Perspectives for Factor V Deficiency Using Recombinant and Advanced Therapies

2021 ◽  
Vol 22 (18) ◽  
pp. 9705
Author(s):  
Sara Bernal ◽  
Irene Pelaez ◽  
Laura Alias ◽  
Manel Baena ◽  
Juan A. De Pablo-Moreno ◽  
...  

Factor V is an essential clotting factor that plays a key role in the blood coagulation cascade on account of its procoagulant and anticoagulant activity. Eighty percent of circulating factor V is produced in the liver and the remaining 20% originates in the α-granules of platelets. In humans, the factor V gene is about 80 kb in size; it is located on chromosome 1q24.2, and its cDNA is 6914 bp in length. Furthermore, nearly 190 mutations have been reported in the gene. Factor V deficiency is an autosomal recessive coagulation disorder associated with mutations in the factor V gene. This hereditary coagulation disorder is clinically characterized by a heterogeneous spectrum of hemorrhagic manifestations ranging from mucosal or soft-tissue bleeds to potentially fatal hemorrhages. Current treatment of this condition consists in the administration of fresh frozen plasma and platelet concentrates. This article describes the cases of two patients with severe factor V deficiency, and of their parents. A high level of mutational heterogeneity of factor V gene was identified, nonsense mutations, frameshift mutations, missense changes, synonymous sequence variants and intronic changes. These findings prompted the identification of a new mutation in the human factor V gene, designated as Jaén-1, which is capable of altering the procoagulant function of factor V. In addition, an update is provided on the prospects for the treatment of factor V deficiency on the basis of yet-to-be-developed recombinant products or advanced gene and cell therapies that could potentially correct this hereditary disorder.

Haemophilia ◽  
2006 ◽  
Vol 12 (2) ◽  
pp. 172-178 ◽  
Author(s):  
N. YAMAKAGE ◽  
M. IKEJIRI ◽  
K. OKUMURA ◽  
A. TAKAGI ◽  
T. MURATE ◽  
...  

1998 ◽  
Vol 101 (1) ◽  
pp. 32-39 ◽  
Author(s):  
Joan F. Guasch ◽  
Suzanne Cannegieter ◽  
Pieter H. Reitsma ◽  
Elizabeth T. Van 't Veer-Korthof ◽  
Rogier M. Bertina

2006 ◽  
Vol 15 (2) ◽  
pp. 102-105
Author(s):  
Mehrez M. Jadaon ◽  
Ali A. Dashti ◽  
Hend L. Lewis

2010 ◽  
Vol 104 (09) ◽  
pp. 514-522 ◽  
Author(s):  
Thomas Lecompte ◽  
Agnès Tournier ◽  
Lise Morlon ◽  
Monique Marchand-Arvier ◽  
Claude Vigneron ◽  
...  

SummaryCathepsin G (Cath G), a serine-protease found in neutrophils, has been reported to have effects that could either facilitate or impede coagulation. Thrombin generation (CAT method) was chosen to study its overall effect on the process, at a plasma concentration (240 nM) observed after neutrophil activation. Coagulation was triggered by tissue factor in the presence of platelets or phospholipid vesicles. To help identify potential targets of Cath G, plasma depleted of clotting factors or of inhibitors was used. Cath G induced a puzzling combination of two diverging effects of varying intensities depending on the phospholipid surface provided: accelerating the process under the three conditions (shortened clotting time by up to 30%), and impeding the process during the same thrombin generation time-course since thrombin peak and ETP (total thrombin potential) were decreased, up to 45% and 12%, respectively, suggestive of deficient prothrombinase. This is consistent with Cath G working on at least two targets in the coagulation cascade. Our data indicate that coagulation acceleration can be attributed neither to platelet activation and nor to activation of a clotting factor. When TFPI (tissue factor pathway inhibitor) was absent, no effect on lag time was observed and the anticoagulant activity of TFPI was decreased in the presence of Cath G. Consistent with the literature and the hypothesis of deficient prothrombinase, experiments using Russel’s Viper Venom indicate that the anticoagulant effect can be attributed to a deleterious effect on factor V. The clinical relevance of these findings deserves to be studied.


1991 ◽  
Vol 78 (2) ◽  
pp. 229-235 ◽  
Author(s):  
Marlene Mazzorana ◽  
Georges Baffet ◽  
Bernard Kneip ◽  
Bernard Launois ◽  
Christiane Guguen-Guillouzo

1995 ◽  
Vol 78 (3) ◽  
pp. 193-200 ◽  
Author(s):  
Maria I. Bokarewa ◽  
Katarina Bremme ◽  
Gunnar Falk ◽  
Margareta Sten-Linder ◽  
Nils Egberg ◽  
...  

1998 ◽  
Vol 13 (4) ◽  
pp. 195-198 ◽  
Author(s):  
Takafumi Seki ◽  
Hiroshi Okayama ◽  
Tomoko Kumagai ◽  
Norihisa Kumasaka ◽  
Masahito Sakuma ◽  
...  

1999 ◽  
Vol 14 (4) ◽  
pp. 357-357 ◽  
Author(s):  
H. Kostka ◽  
G. Siegert ◽  
S. Gehrisch ◽  
E. Kuhlisch ◽  
E. Runge ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-5
Author(s):  
Takaaki Kato ◽  
Takaya Hanawa ◽  
Mea Asou ◽  
Tomohiko Asakawa ◽  
Hisashi Sakamaki ◽  
...  

A 70-year-old man presented to our hospital with intramuscular hemorrhage in the right thigh. He had exhibited a tendency to bleed for the last 16 years and had visited several medical institutions, but no diagnosis had been made. Since the risk of sudden bleeding was assumed to be high due to his age, we decided to examine him in our department. A coagulation abnormality with prothrombin time-international normalized ratio (PT-INR) of 4.5 and activated partial thromboplastin time (aPTT) of 99.6 seconds was observed, but the platelet count, fibrinogen, and PIVKAII were within normal limits. Coagulation activities of factor V, VII, VIII, IX, X, XI, XII, and XIII were all reduced. Anti-factor VIII and IX antibodies which were measured by the Bethesda method, lupus anti-coagulant (diluted Russell snake venom time method) and anti-cardiolipin antibody were also positive. The results of these tests were comparable to those undertaken 15 years ago when they were scrutinized at the university hospital. We suspected the presence of anti-factor V antibodies because there was a dissociation between the thrombotest values measured and those calculated from the PT-INR. Moreover, cross-mixing test showed an immediate inhibitor pattern. Subsequently, factor V antibodies were confirmed by the immunoblot method and the diagnosis of autoimmune factor V deficiency was made. When factor V, which is downstream of the coagulation cascade, is inhibited, coagulation test using the one-stage clotting method shows a pseudolow value. Therefore, extensive abnormalities of coagulation factor activity and inhibitor assay should be interpreted with caution, and the presence of a high titer of factor V inhibitor should be considered.


Sign in / Sign up

Export Citation Format

Share Document