scholarly journals Bacteriological Evaluation of Gingival Crevicular Fluid in Teeth Restored Using Fixed Dental Prostheses: An In Vivo Study

2021 ◽  
Vol 22 (11) ◽  
pp. 5463
Author(s):  
Artak Heboyan ◽  
Mikayel Manrikyan ◽  
Muhammad Sohail Zafar ◽  
Dinesh Rokaya ◽  
Ruzan Nushikyan ◽  
...  

The present in vivo study determined the microbiological counts of the gingival crevicular fluid (GCF) among patients with fixed dental prostheses fabricated using three different techniques. A total of 129 subjects were divided into three study groups: first, cobalt-chrome-based, metal-ceramic prostheses fabricated by the conventional method (MC, n = 35); the second group consisted of cobalt-chrome-based, metal-ceramic prostheses fabricated by the computer-aided design and computer-aided manufacturing (CAD/CAM) technique (CC-MC, n = 35); the third group comprised zirconia-based ceramic prostheses fabricated using the CAD/CAM technique (CC-Zr, n = 35). The control consisted of 24 patients using prostheses fabricated with either MC, CC-MC, or CC-Zr. The GCF was obtained from the subjects before treatment, and 6 and 12 months after the prosthetic treatment. Bacteriological and bacterioscopic analysis of the GCF was performed to analyze the patients’ GCF. The data were analyzed using SPSS V20 (IBM Company, Chicago, IL, USA). The number of microorganisms of the gingival crevicular fluid in all groups at 12 months of prosthetic treatment reduced dramatically compared with the data obtained before prosthetic treatment. Inflammatory processes in the periodontium occurred slowly in the case of zirconium oxide-based ceramic constructions due to their biocompatibility with the mucous membranes and tissues of the oral cavity as well as a reduced risk of dental biofilm formation. This should be considered by dentists and prosthodontists when choosing restoration materials for subjects with periodontal pathology.

Molecules ◽  
2020 ◽  
Vol 25 (20) ◽  
pp. 4650
Author(s):  
Artak Heboyan ◽  
Azeem Ul Yaqin Syed ◽  
Dinesh Rokaya ◽  
Paul R. Cooper ◽  
Mikael Manrikyan ◽  
...  

Cytomorphometry is used in the sampling of biological materials and diagnostic procedures. The use of cytological studies in periodontal diseases is not well described in the literature. Our study aimed to quantitatively assess the inflammation dynamics using cytomorphometric analysis of the periodontium before and after the use of fixed dental prostheses. Following ethics approval, a total of 105 subjects were divided in 3 groups as gingivitis (n = 23), periodontitis (n = 58), and healthy periodontium (control) (n = 24). The fixed dental prostheses (crowns and fixed partial dentures) were fabricated from cobalt-chrome metal-ceramic prostheses using the conventional method (C/M-CoCr), cobalt-chrome metal-ceramic prostheses by the computer-aided design and computer-aided manufacturing (CAD/CAM) technique (C/C-CoCr), and zirconia-based ceramic prostheses by the CAD/CAM technique (C/C-Zr) among subjects with gingivitis and periodontitis. The gingival crevicular fluid (GCF) was obtained from subjects before and after the use of the prostheses. The total count of epithelial cells and the connective tissue cells or polymorphonuclear neutrophils (PMNs) in GCF were studied using cytomorphometric analysis. The Statistical Package Tor the Social Sciences (SPSS), Version 20 (IBM Company, Chicago, IL, USA) was used to analyze the results and the significance level was set at p = 0.05. The data for before and after the use of the prostheses were compared using independent t-Tests. Similarly, the results after the use of prostheses in gingivitis, periodontitis, and control in each type of prostheses were compared using One-way ANOVA with post hoc using Scheffe. The total epithelial cells and the PMNs were determined along with the epithelium/leukocyte index. Regardless of the prostheses type used, no significant change in the parameters was identified among patients with a healthy periodontium, before and after prosthetic treatment. In all study groups, a statistically increase (p value < 0.05) was observed in the oral epithelial cell counts and a statistically decrease (p < 0.05) in the PMNs count following the use of the fixed prostheses. Data on cytomorphometric analysis could enable the selection of the most appropriate prostheses for use in patients with periodontal pathologies. When choosing prostheses, changes in the composition of GCF could be considered as a useful criterion for their use.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1401
Author(s):  
Doo-Bin Song ◽  
Man-So Han ◽  
Si-Chul Kim ◽  
Junyong Ahn ◽  
Yong-Woon Im ◽  
...  

This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses.


2020 ◽  
Vol 10 (21) ◽  
pp. 7735
Author(s):  
Hai Yen Mai ◽  
Jae-Min Seo ◽  
Jae-Kwang Jung ◽  
Du-Hyeong Lee

Occlusal contact loss occasionally occurs following the placement of implant-supported fixed dental prostheses in the posterior region. This complication is caused by the change in the vertical dimension of occlusion after the recovery of mastication. The change is probably related to the prosthesis sinking phenomenon and previous mandibular dislocation. The use of interim prostheses could help re-establish the vertical dimension of occlusion. The definitive prostheses can then be accurately fabricated using digital techniques in the newly established vertical dimension. In this case report, we introduce a protocol incorporating a computer-aided design and computer-aided manufacturing (CAD-CAM) interim prosthesis and digital techniques to minimize the occurrence of unexpected initial occlusal changes in the prosthetic treatment of implant-supported prostheses in the posterior region.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5588
Author(s):  
Angelika Rauch ◽  
Sebastian Hahnel ◽  
Elena Günther ◽  
Wolfgang Bidmon ◽  
Oliver Schierz

The aim of this study was to compare the clinical properties of tooth-colored computer-aided design/computer-aided manufacturing (CAD/CAM) materials for the fabrication of a 3-unit fixed dental prostheses (FDPs) in the same clinical scenario. A 53-year-old female patient was supplied with a 3-unit FDP to replace a second premolar in the upper jaw. Restorations were fabricated from 3 mol%, 4 mol%, and 5 mol% yttrium oxide zirconia, zirconia with translucency gradient, indirect composite resin, polyetheretherketone (PEEK), and polyetherketoneketone (PEKK). Milling time, weight, and radiopacity were investigated. Esthetics were examined following the US Public Health Service criteria (USPHS). The milling time for zirconia was twice as high as for the indirect composite resin, PEEK, or PEKK. The latter materials had a weight of 2 g each, while zirconia restorations yielded 5 g. Zirconia presented intense radiopacity. PEEK and PEKK required veneering and an opaquer was applied to the PEKK framework. All FDPs showed acceptable esthetics. PEEK and PEKK restorations were featured by a grayish shimmering. A variety of CAD/CAM materials are available to fabricate 3-unit FDPs with esthetically acceptable results. In the esthetic zone, PEEK and PEKK require veneering and an opaquer might be applied. Milling time, weight, and radiopacity were relatively high for zirconia FDPs.


1998 ◽  
Vol 25 (12) ◽  
pp. 1017-1021 ◽  
Author(s):  
W. A. Soskolne ◽  
T. Chajek ◽  
M. Flashner ◽  
I. Landau ◽  
A. Stabholtz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document