scholarly journals An Adaptive Differential Protection and Fast Auto-Closing System for 10 kV Distribution Networks Based on 4G LTE Wireless Communication

2019 ◽  
Vol 12 (1) ◽  
pp. 2 ◽  
Author(s):  
Wen An ◽  
Jun Jie Ma ◽  
Hong Yang Zhou ◽  
Hong Shan Chen ◽  
Xu Jun ◽  
...  

With the development of wireless communication technology and computer technology, more and more smart technologies have been applied in electricity distribution networks. This paper presents an adaptive current differential protection and fast auto-closing system for application in 10 kV distribution networks in China Southern Power Grid. The current differential protection can adaptively change its settings according to the topology change of the primary distribution networks, thus the system effectively reduces the operation and maintenance cost of the power distribution network. In order to restore the power supply for the healthy part of the 10 kV networks quickly after a power system fault is cleared, the protection and control system provides wide area control function for automatic fault isolation and automatic switching. The traditional overcurrent protection and control system have no fault location function, it may take several minutes or even hours to manually locate a fault and then restore the power supply. Compared with the protection and control system of the traditional 10 kV distribution networks, the system developed can locate and isolate faults within 900 ms (assuming that the operating time of the load switch is 700 ms), and can quickly restore power supply in less than one second after a power system fault is cleared.

Author(s):  
Bin Li ◽  
Jiawei He ◽  
Ye Li ◽  
Botong Li

AbstractThe multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this paper, the single-ended protections, namely, the traveling-wave based protection and transient-variable based protection, as well as the pilot protections, mainly including the directional pilot protection and current differential protection, are discussed in detail. With the analyzed protections, the effective main and back-up protection strategy can be configured for the dc line in multi-terminal VSC-HVDC grid.


Author(s):  
Maxim V. Balagurov ◽  
Petr A. Bachurin ◽  
Abilmansur R. Mansurov ◽  
Dmitry B. Kuguchev ◽  
Vladimir S. Meshalkin ◽  
...  

1989 ◽  
Vol 9 (7) ◽  
pp. 51-52 ◽  
Author(s):  
M. Suzuki ◽  
T. Matsuda ◽  
N. Ohashi ◽  
Y. Sano ◽  
R. Tsukui ◽  
...  

2017 ◽  
Vol 32 (1) ◽  
pp. 361-369 ◽  
Author(s):  
Glauco N. Taranto ◽  
Tatiana M. L. Assis ◽  
Djalma M. Falcao ◽  
Roberto C. de Carvalho

Sign in / Sign up

Export Citation Format

Share Document