scholarly journals Impact of Tube Bundle Placement on the Thermal Charging of a Latent Heat Storage Unit

Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1289
Author(s):  
Mohammad Ghalambaz ◽  
Amir Hossein Eisapour ◽  
Hayder I. Mohammed ◽  
Mohammad S. Islam ◽  
Obai Younis ◽  
...  

The melting process of a multi-tube’s thermal energy storage system in the existence of free convection effects is a non-linear and important problem. The placement of heated tubes could change the convective thermal circulation. In the present study, the impact of the position of seven heat exchanger tubes was systematically investigated. The energy charging process was numerically studied utilizing liquid fraction and stored energy with exhaustive temperature outlines. The tubes of heat transfer fluid were presumed in the unit with different locations. The unit’s heat transfer behavior was assessed by studying the liquid fraction graphs, streamlines, and isotherm contours. Each of the design factors was divided into four levels. To better investigate the design space for the accounted five variables and four levels, an L16 orthogonal table was considered. Changing the location of tubes could change the melting rate by 28%. The best melting rate was 94% after four hours of charging. It was found that the tubes with close distance could overheat each other and reduce the total heat transfer. The study of isotherms and streamlines showed the general circulation of natural convection flows at the final stage of melting was the most crucial factor in the melting of top regions of the unit and reduces the charging time. Thus, particular attention to the tubes’ placement should be made so that the phase change material could be quickly melted at both ends of a unit.

Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1425
Author(s):  
Tarek Bouzennada ◽  
Farid Mechighel ◽  
Kaouther Ghachem ◽  
Lioua Kolsi

A 2D-symmetric numerical study of a new design of Nano-Enhanced Phase change material (NEPCM)-filled enclosure is presented in this paper. The enclosure is equipped with an inner tube allowing the circulation of the heat transfer fluid (HTF); n-Octadecane is chosen as phase change material (PCM). Comsol-Multiphysics commercial code was used to solve the governing equations. This study has been performed to examine the heat distribution and melting rate under the influence of the inner-tube position and the concentration of the nanoparticles dispersed in the PCM. The inner tube was located at three different vertical positions and the nanoparticle concentration was varied from 0 to 0.06. The results revealed that both heat transfer/melting rates are improved when the inner tube is located at the bottom region of the enclosure and by increasing the concentration of the nanoparticles. The addition of the nanoparticles enhances the heat transfer due to the considerable increase in conductivity. On the other hand, by placing the tube in the bottom area of the enclosure, the liquid PCM gets a wider space, allowing the intensification of the natural convection.


Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2264 ◽  
Author(s):  
Sebastian Ammann ◽  
Andreas Ammann ◽  
Rebecca Ravotti ◽  
Ludger Fischer ◽  
Anastasia Stamatiou ◽  
...  

The problem of emulsification between Phase Change Material (PCM) and Heat Transfer Fluid (HTF) in direct contact latent heat storage systems has been reported in various studies. This issue causes the PCM to flow out of the storage tank and crystallize at unwanted locations and thus presents a major limitation for the proper operation of such systems. These anomalies become more pronounced when high HTF flow rates are employed with the aim to achieve fast heat transfer rates. The goal of this paper is to find a method which will enable the fast separation of the formed emulsion and thus the uninterrupted operation of the storage unit. In this study, three separation methods were examined and the use of superhydrophobic filters was chosen as the best candidate for the demulsification of the PCM and HTF mixtures. The filter was produced by processing of a melamine sponge with different superhydrophobic adhesives and was tested with emulsions closely resembling the ones formed in a real direct contact setup. The superhydrophobic filter obtained, was able to separate the emulsions effectively while presenting a very high permeability (up to 1,194,980 kg h−1 m−2 bar−1). This is the first time the use of a superhydrophobic sponge has been investigated in the context of demulsification in direct contact latent heat storage.


Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3211
Author(s):  
Min Li ◽  
Jasim M. Mahdi ◽  
Hayder I. Mohammed ◽  
Dmitry Olegovich Bokov ◽  
Mustafa Z. Mahmoud ◽  
...  

Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that moving the HTF tubes to medium positions along the vertical direction is relatively better for enhancing the solidification of PCM with multiple HTF tubes. Repositioning of the HTF tubes on the left side of the unit can slightly improve the heat removal rate by about 0.2 in the case of p5-u-1 and decreases by 1.6% in the case of p5-u-2. It was found also that increasing the distance between the tubes in the vertical direction has a detrimental effect on the PCM solidification mode. Replacing the HTF tubes on the left side of the unit negatively reduces the heat removal rate by about 1.2 and 4.4%, respectively. Further, decreasing the HTF temperature from 15 °C to 10 and 5 °C can increase the heat removal rate by around 7 and 16%, respectively. This paper indicates that the specific concern to the HTF tube arrangement should be made to improve the discharging process attending free convection impact in phase change heat storage.


2021 ◽  
Vol 19 ◽  
pp. 589-592
Author(s):  
M. Hariss ◽  
◽  
M. El Alami ◽  
A. Gounni

In this work, a numerical study is performed to analyze the impact of honeycomb structure on heat transfer within the PCM. The modeling is based on a transient calculation making it possible to analyze the phase change of the paraffin using the commercial software "Fluent" based on the enthalpy-porosity model. The results showed that the impregnation of a metal matrix in a rectangular enclosure helps to decrease the melting time and thus improve the heat transfer within the PCM.


2016 ◽  
Vol 64 (2) ◽  
pp. 401-408
Author(s):  
J. Karwacki ◽  
K. Bogucka-Bykuć ◽  
W. Włosiński ◽  
S. Bykuć

Abstract This paper presents an experimental study performed with the general aim of defining procedures for calculation and optimization of shell-and-tube latent thermal energy storage unit with metals or metal alloys as PCMs. The experimental study is focused on receiving the exact information about heat transfer between heat transfer fluid (HTF) and phase change material (PCM) during energy accumulation process. Therefore, simple geometry of heat transfer area was selected. Two configurations of shell-and-tube thermal energy storage (TES) units were investigated. The paper also highlights the emerging trend (reflected in the literature) with respect to the investigation of metal PCM-based heat storage units in recent years and shortly presents unique properties and application features of this relatively new class of PCMs.


Nanomaterials ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 2647
Author(s):  
Xinguo Sun ◽  
Hayder I. Mohammed ◽  
Mohammadreza Ebrahimnataj Tiji ◽  
Jasim M. Mahdi ◽  
Hasan Sh. Majdi ◽  
...  

Inherent fluctuations in the availability of energy from renewables, particularly solar, remain a substantial impediment to their widespread deployment worldwide. Employing phase-change materials (PCMs) as media, saving energy for later consumption, offers a promising solution for overcoming the problem. However, the heat conductivities of most PCMs are limited, which severely limits the energy storage potential of these materials. This study suggests employing circular fins with staggered distribution to achieve improved thermal response rates of PCM in a vertical triple-tube heat exchanger involving two opposite flow streams of the heat-transfer fluid (HTF). Since heat diffusion is not the same at various portions of the PCM unit, different fin configurations, fin dimensions and HTF flow boundary conditions were explored using computational studies of melting in the PCM triple-tube system. Staggered configuration of fin distribution resulted in significant increases in the rates of PCM melting. The results indicate that the melting rate and heat charging rate could be increased by 37.2 and 59.1%, respectively, in the case of staggered distribution. Furthermore, the use of lengthy fins with smaller thickness in the vertical direction of the storage unit resulted in a better positive role of natural convection; thus, faster melting rates were achieved. With fin dimensions of 0.666 mm × 15 mm, the melting rate was found to be increased by 23.6%, when compared to the base case of 2 mm × 5 mm. Finally, it was confirmed that the values of the Reynolds number and inlet temperatures of the HTF had a significant impact on melting time savings when circular fins of staggered distribution were included.


2017 ◽  
Vol 139 (4) ◽  
Author(s):  
Guansheng Chen ◽  
Nanshuo Li ◽  
Huanhuan Xiang ◽  
Fan Li

It is well known that attaching fins on the tubes surfaces can enhance the heat transfer into and out from the phase change materials (PCMs). This paper presents the results of an experimental study on the thermal characteristics of finned coil latent heat storage unit (LHSU) using paraffin as the phase change material (PCM). The paraffin LHSU is a rectangular cube consists of continuous horizontal multibended tubes attached vertical fins at the pitches of 2.5, 5.0, and 7.5 mm that creates the heat transfer surface. The shell side along with the space around the tubes and fins is filled with the material RT54 allocated to store energy of water, which flows inside the tubes as heat transfer fluid (HTF). The measurement is carried out under four different water flow rates: 1.01, 1.30, 1.50, and 1.70 L/min in the charging and discharging process, respectively. The temperature of paraffin and water, charging and discharging wattage, and heat transfer coefficient are plotted in relation to the working time and water flow rate.


Heat Transfer ◽  
2020 ◽  
Vol 49 (5) ◽  
pp. 2659-2685
Author(s):  
Digant S. Mehta ◽  
Bhavesh Vaghela ◽  
Manish K. Rathod ◽  
Jyotirmay Banerjee

Sign in / Sign up

Export Citation Format

Share Document