scholarly journals The Impact of Nanofluids on Droplet/Spray Cooling of a Heated Surface: A Critical Review

Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 80
Author(s):  
Yunus Tansu Aksoy ◽  
Yanshen Zhu ◽  
Pinar Eneren ◽  
Erin Koos ◽  
Maria Rosaria Vetrano

Cooling by impinging droplets has been the subject of several studies for decades and still is, and, in the last few years, the potential heat transfer enhancement obtained thanks to nanofluids’ use has received increased interest. Indeed, the use of high thermal conductivity fluids, such as nanofluids’, is considered today as a possible way to strongly enhance this heat transfer process. This enhancement is related to several physical mechanisms. It is linked to the nanofluids’ rheology, their degree of stabilization, and how the presence of the nanoparticles impact the droplet/substrate dynamics. Although there are several articles on droplet impact dynamics and nanofluid heat transfer enhancement, there is a lack of review studies that couple these two topics. As such, this review aims to provide an analysis of the available literature dedicated to the dynamics between a single nanofluid droplet and a hot substrate, and the consequent enhancement or reduction of heat transfer. Finally, we also conduct a review of the available publications on nanofluids spray cooling. Although using nanofluids in spray cooling may seem a promising option, the few works present in the literature are not yet conclusive, and the mechanism of enhancement needs to be clarified.

Fluids ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 25
Author(s):  
Iris Gerken ◽  
Thomas Wetzel ◽  
Jürgen J. Brandner

Micro heat exchangers have been revealed to be efficient devices for improved heat transfer due to short heat transfer distances and increased surface-to-volume ratios. Further augmentation of the heat transfer behaviour within microstructured devices can be achieved with heat transfer enhancement techniques, and more precisely for this study, with passive enhancement techniques. Pin fin geometries influence the flow path and, therefore, were chosen as the option for further improvement of the heat transfer performance. The augmentation of heat transfer with micro heat exchangers was performed with the consideration of an improved heat transfer behaviour, and with additional pressure losses due to the change of flow path (pin fin geometries). To capture the impact of the heat transfer, as well as the impact of additional pressure losses, an assessment method should be considered. The overall exergy loss method can be applied to micro heat exchangers, and serves as a simple assessment for characterization. Experimental investigations with micro heat exchanger structures were performed to evaluate the assessment method and its importance. The heat transfer enhancement was experimentally investigated with microstructured pin fin geometries to understand the impact on pressure loss behaviour with air.


Author(s):  
Eelco Gehring ◽  
Mario F. Trujillo

A primary mechanism of heat transfer in spray cooling is the impingement of numerous droplets onto a heated surface. This mechanism is isolated in the present and ongoing work by numerically simulating the impact of a single train of FC-72 droplets employing an implicit free surface capturing methodology. The droplet frequency and velocity ranges from 2000–4000 Hz, and 0.5–2 m/s, respectively, with a fixed drop size of 239 μm. This gives a corresponding Weber and Reynolds range of 10–170 and 330–1300, respectively. Results show that the impingement zone is largely free of phase change effects due to the efficient suppression of the local temperature field well below the saturated value. Due in part to the relatively high value of the Prandtl number and the compression of the boundary layer from the impingement flow, a cell size on the order of 1 μm is necessary to adequately capture the heat transfer dynamics. It is shown that the cooling behavior increases in relation to increasing frequency and impact velocity, but is most sensitive to velocity. In fact, for sufficiently low velocities the calculations show that the momentum imparted on the film is insufficient to maintain a near stationary liquid crown. The consequence is a noticeable penalty on the cooling behavior.


Author(s):  
Jayesh P ◽  
Mukkamala Y ◽  
Bibin John

Heat transfer enhancement, pumping power and weight minimization in enhanced heat exchangers has long been achieved by deploying tubes with internal surface modifications like microgrooves, ribs, fins, knurls, and dimples with and without tube inserts. This article presents a very extensive review of experimental and computational studies on heat transfer enhancement, which covers convectional and unconventional working fluids under different fluid flow conditions. Compound augmentation with tube surface modifications and inserts has yielded enhancements in the overall heat transfer coefficient of over 116% in the fully developed turbulent flow regime. Exotic fluids like nano-coolants deployed in spiral grooved mircofin tubes yielded 196% enhancement in tube side heat transfer rate for concentrations as low as 0.5% by volume, while the thermal efficiency index measuring the overall enhancement in relation to the pumping power was 75%. However, reviews that address the combined effect of unconventional fluids, surface modifications and tube inserts on the overall thermo-hydraulic performance of annular heat exchangers seem to be limited. Further, nano-coolants aren’t frequently used in the process industry. The goal of this study is to document and evaluate the impact of cost-effective and energy-saving passive enhancement techniques such as tube surface modifications, tube inserts, and annular enhancement techniques on annular heat exchangers used in the process industries with Newtonian and non-Newtonian fluids. This review should be useful to engineers, academics and medical professionals working with non-Newtonian fluids and enhanced heat exchangers.


2018 ◽  
Vol 140 (11) ◽  
Author(s):  
Jian-nan Chen ◽  
Rui-na Xu ◽  
Zhen Zhang ◽  
Xue Chen ◽  
Xiao-long Ouyang ◽  
...  

Enhancing spray cooling with surface structures is a common, effective approach for high heat flux thermal management to guarantee the reliability of many high-power, high-speed electronics and to improve the efficiency of new energy systems. However, the fundamental heat transfer enhancement mechanisms are not well understood especially for nanostructures. Here, we fabricated six groups of nanowire arrayed surfaces with various structures and sizes that show for the first time how these nanostructures enhance the spray cooling by improving the surface wettability and the liquid transport to quickly rewet the surface and avoid dry out. These insights into the nanostructure spray cooling heat transfer enhancement mechanisms are combined with microstructure heat transfer mechanism in integrated microstructure and nanostructure hybrid surface that further enhances the spray cooling heat transfer.


Author(s):  
Khaled J. Hammad

Heat transfer enhancement in suddenly expanding annular pipe flows of a shear-thinning non-Newtonian fluid is studied within the steady laminar flow regime. Conservation of mass, momentum, and energy equations, along with the power-law constitutive model are numerically solved. The impact of inflow inertia, annular-nozzle-diameter-ratio, k, power-law index, n, and Prandtl numbers, is reported for: Re = {50, 100}, k = {0, 0.5, 0.7}; n = {1, 0.8, 0.6}; and Pr = {1, 10, 100}. Heat transfer enhancement downstream of the expansion plane, i.e., Nusselt numbers, Nu, higher than the fully developed value, in the downstream pipe, is observed only for Pr = 10 and 100. Higher Prandtl numbers, power-law index values, and annular diameter ratios, in general, reflect a more dramatic heat transfer augmentation downstream of the expansion plane. Heat transfer augmentation for Pr = 10 and 100, is more dramatic for suddenly expanding annular flows, in comparison with suddenly expanding pipe flow. For a given annular diameter ratio and Reynolds numbers, increasing the Prandtl number from Pr = 10 to Pr = 100, always results in higher peak Nu values, for both Newtonian and shear-thinning non-Newtonian flows.


2019 ◽  
Vol 141 (7) ◽  
Author(s):  
Lei Luo ◽  
Zhiqi Zhao ◽  
Xiaoxu Kan ◽  
Dandan Qiu ◽  
Songtao Wang ◽  
...  

This paper numerically investigated the impact of the holes and their location on the flow and tip internal heat transfer in a U-bend channel (aspect ratio = 1:2), which is applicable to the cooling passage with dirt purge holes in the mid-chord region of a typical gas turbine blade. Six different tip ejection configurations are calculated at Reynolds numbers from 25,000 to 200,000. The detailed three-dimensional flow and heat transfer over the tip wall are presented, and the overall thermal performances are evaluated. The topological methodology, which is first applied to the flow analysis in an internal cooling passage of the blade, is used to explore the mechanisms of heat transfer enhancement on the tip wall. This study concludes that the production of the counter-rotating vortex pair in the bend region provides a strong shear force and then increases the local heat transfer. The side-mounted single hole and center-mounted double holes can further enhance tip heat transfer, which is attributed to the enhanced shear effect and disturbed low-energy fluid. The overall thermal performance of the optimum hole location is a factor of 1.13 higher than that of the smooth tip. However, if double holes are placed on the upstream of a tip wall, the tip surface cannot be well protected. The results of this study are useful for understanding the mechanism of heat transfer enhancement in a realistic gas turbine blade and for efficient designing of blade tips for engine service.


Author(s):  
Yi-Hsuan Huang ◽  
Chiao-Hsin Chen ◽  
Yao-Hsien Liu

Heat transfer of air/water mist flow in a single-side heated vertical duct was experimentally investigated. The mist flow was produced by introducing fine dispersed water droplets into the air stream, and the water–air mass flow ratios were up to 15%. The Reynolds numbers of the air flow were 7900, 16,000, and 24,000. The rib spacing-to-height ratios were 10 and 20 in the current study. Mist flow cooling achieved higher heat transfer rates mainly because of the droplet deposition and liquid film formation on the heated surface. The heat transfer enhancement on the smooth surface by the mist flow was 4–6 times as high as the air flow. On the ribbed surface, a smaller rib spacing of 10 was preferred for air cooling, since the heat transfer enhancement by the flow reattachment was better utilized. However, the rib-induced secondary flow blew away the liquid films on the surface, and the heat transfer enhancement was degraded near the reattachment region for the mist cooling. A larger rib spacing-to-height ratio of 20 thus achieved higher heat transfer because of the liquid film formation beyond the reattachment region. The heat transfer enhancement on the ribbed surface using mist flow was 2.5–3.5 times as high as the air flow. The friction factor of the mist flow was two times as high as the air flow in the ribbed duct.


Mathematics ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 653 ◽  
Author(s):  
Ali Rehman ◽  
Zabidin Salleh ◽  
Taza Gul ◽  
Zafar Zaheer

The unsteady flow of nanoliquid film over a flexible surface has been inspected. Water and ethylene glycol are used as the base liquids for the graphene oxide platelets. The comparison of two sorts of nanoliquids has been used for heat transfer enhancement applications. The thickness of the nanoliquid film is kept as a variable. The governing equations for the flow problem have been altered into the set of nonlinear differential equations. The BVP 2.0 package has been used for the solution of the problem. The sum of the square residual error has been calculated up to the 10th order approximations. It has been observed that the graphene oxide ethylene glycol based nanofluid (GO-EG) is more efficient for heat transfer enhancement as compared to the graphene oxide water based nanofluid (GO-W). The impact of the physical parameters has been plotted and discussed.


Sign in / Sign up

Export Citation Format

Share Document