scholarly journals The Effect of Coupling Solar Thermal System and Geothermal Heat Pump Systems in Areas with Unbalanced Heating and Cooling Demand

Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 31
Author(s):  
Jihyun Hwang ◽  
Doosam Song ◽  
Taewon Lee

Geothermal source heat pump (GSHP) systems as renewable energy systems are being more frequently installed as part of the zero-energy building drive. However, in South Korea, where a large amount of heating load can be required, maintaining high system performance by using only a GSHP is difficult owing to the gradual degradation of its thermal performance. The performance of a solar-assisted GSHP system was therefore experimentally analyzed and compared with a GSHP-only system. The results showed that the heating coefficient of performance of the GSHP-only operation was 5.4, while that of the solar-assisted GSHP operation was 7.0. In the case of the GSHP-only system, the maximum temperature of the heat pump water supply on the heat source side was initially 13.1 °C, but this rapidly decreased to 11.4 °C during operation. For the solar-assisted GSHP system, the temperature of the water supply to the heat source side of the heat pump was controlled at 15–20.9 °C, and the power consumption for system operation was reduced by about 20% compared with that for the GSHP-only system. Much higher temperatures could be supplied when solar heat is used instead of ground heat, as solar heat contributes to the performance improvement of the heat pump system.

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Akbar Alidadi Shamsabadi ◽  
Mehdi Jahangiri ◽  
Tayebeh Rezaei ◽  
Rouhollah Yadollahi Farsani ◽  
Ali Seryani ◽  
...  

Purpose In this study, a solar water heating system along with a seasonal thermal energy storage and a heat pump is designed for a villa with an area of 192 m2 in Tehran, the capital of Iran. Design/methodology/approach According to the material and the area of the residential space, the required heating of the building was calculated manually and then the thermodynamic analysis of the system and simulation was done in MATLAB software. Finally, regarding the waste of system, an efficient solar heating system, providing all the required energy to heat the building, was obtained. Findings The surface area of the solar collector is equal to 46 m2, the capacity of the tank is about 2,850 m3, insulation thickness stands at 55 cm and the coefficient of performance in required heat pump is accounted to about 9.02. Also, according to the assessments, the maximum level of received energy by the collector in this system occurs at a maximum temperature of 68ºC. Originality/value To the best of the authors’ knowledge, in the present work, for the first time, using mathematical modeling and analyzing of the first and second laws of thermodynamics, as well as using of computational code in MATLAB software environment, the solar-assisted ground source heat pump system is simulated in a residential unit located in Tehran.


2010 ◽  
Vol 31 (2) ◽  
pp. 77-94 ◽  
Author(s):  
Agnieszka Kuczyńska ◽  
Władysław Szaflik

Absorption and adsorption chillers applied to air conditioning systemsThis work presents an application possibility of sorption refrigerators driven by low temperature fluid for air conditioning of buildings. Thermodynamic models were formulated and absorption LiBr-water chiller with 10 kW cooling power as well as adsorption chiller with silica gel bed were investigated. Both of them are using water for desorption process with temperatureTdes= 80 °C. Coefficient of performance (COP) for both cooling cycles was analyzed in the same conditions of the driving heat source, cooling waterTc= 25 °C and temperature in evaporatorTevap= 5 °C. In this study, the computer software EES was used to investigate the performance of absorption heat pump system and its behaviour in configuration with geothermal heat source.


2020 ◽  
Vol 216 ◽  
pp. 01125
Author(s):  
Mexriya Koroly ◽  
Anvar Anarbaev ◽  
Alisher Usmanov ◽  
Kuvondyk Soliev

In this paper, there is analyzed the results of exergy economic optimization of heat-cooling supply in building by using the solar heat pump system. It is possible to realize a system having high reliability in operation of the system. The solar heat pump system according to the present technical decision has high energy efficiency while ensuring reliability, and is useful as a domestic air conditioning and heating water heater. It can also be applied to uses such as industrial heating and cooling devices.


2011 ◽  
Vol 374-377 ◽  
pp. 398-404 ◽  
Author(s):  
Ying Ning Hu ◽  
Ban Jun Peng ◽  
Shan Shan Hu ◽  
Jun Lin

A hot-water and air-conditioning (HWAC) combined ground sourse heat pump(GSHP) system with horizontal ground heat exchanger self-designed and actualized was presented in this paper. The heat transfer performance for the heat exchanger of two different pipe arrangements, three layers and four layers, respectively, was compared. It showed that the heat exchange quantity per pipe length for the pipe arrangement of three layers and four layers are 18.0 W/m and 15.0 W/m. The coefficient of performance (COP) of unit and system could remain 4.8 and 4.2 as GSHP system for heating water, and the COP of heating and cooling combination are up to 8.5 and 7.5, respectively. The power consumption of hot-water in a whole year is 9.0 kwh/t. The economy and feasibility analysis on vertical and horizontal ground heat exchanger were made, which showed that the investment cost per heat exchange quantity of horizontal ground heat exchanger is 51.4% lower than that of the vertical ground heat exchanger, but the occupied area of the former is 7 times larger than the latter's.


2018 ◽  
Vol 3 (2) ◽  
pp. 58-61
Author(s):  
Agnieszka Lisowska-Lis ◽  
Robert Leszczyński

The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.


2018 ◽  
Vol 40 (3) ◽  
pp. 360-378
Author(s):  
Songhui Ai ◽  
Baolong Wang ◽  
Xianting Li ◽  
Wenxing Shi

Solution regeneration of the heat-source tower is significant to guarantee the normal operation of the heat-source tower. Mechanical vapor recompression system is an efficient system for evaporation of solution. In this paper, mechanical vapor recompression system is applied to regenerate solution of heat-source tower. To clarify the merits of mechanical vapor recompression solution regeneration system, several typical solution regeneration systems are modelled. As a result, mechanical vapor recompression shows 35.7%, 73.5% and 91.2% energy saving compared to air-driven heat pump, three-effect evaporating system, and single effect evaporating system, respectively. Furthermore, a heat-source tower heat pump with solution generation system is installed in a typical building in Yangtze river region. The whole heating season performance is simulated to find the effects of different solution regeneration system on the whole heat pump system. As a conclusion, the seasonal coefficient of performance of heat pump is decreased 1.6% by mechanical vapor recompression regeneration system. Comparatively, the seasonal coefficient of performance of heat pump is decreased 2.6%, 4.2% and 10.0% by air-driven heat pump, three-effect evaporating system, and single effect evaporating system, respectively. Practical application: Solution regeneration systems for heat-source tower heat pump systems have been applied in building projects especially in hot summer and cold winter zone in China based on previous investigation. A heat-source tower heat pump system combined with heat pump solution regeneration system has been applied in an office building in Changsha, Hunan Province in China. And its practical operation energy consumption has been reduced obviously compared with traditional single effect evaporation system. Therefore, it is of vital importance to demonstrate the operating performance of different solution regeneration systems applied in heat-source tower heat pump systems in building.


2014 ◽  
Vol 953-954 ◽  
pp. 650-654
Author(s):  
Chao Yi Tan ◽  
Hui Zhu ◽  
Hai Hua Hu ◽  
Meng Meng Wang ◽  
Han Qing Wang

Taking the geothermal heat pump system in the campus of Hunan University of Technology for example, three technical solutions of the heat source of the system were analyzed in terms of the condensing heat load, the annual unbalanced heat load and the energy efficiency ratio (EER) of the system. In addition, comparison was conducted among the solutions. The results indicate that the solution 3, which has a cold and hot water integrative unit and hot water unit connected in series, meanwhile has a cooling tower for auxiliary cooling, shows better performance among all the solutions. The analysis on the solution of heat source of geothermal heat pump system, which usually contains the analysis on the condensing heat load, annual unbalanced heat load and EER, is of great significance for the design and development of the geothermal heat pump system with lower coat and higher EER.


2022 ◽  
Vol 9 ◽  
Author(s):  
Yu-Jin Kim ◽  
Libing Yang ◽  
Evgueniy Entchev ◽  
Soolyeon Cho ◽  
Eun-Chul Kang ◽  
...  

In this paper, the development and demonstration of a hybrid solar geothermal heat pump polygeneration system is presented. The poly-generation system has been designed, modeled, and simulated in TRNSYS software environment. Its performance was assessed followed by installation and demonstration at a demo site in Cheongju, Korea. The space heating and cooling load of the building is 13.8 kW in heating mode at an ambient temperature of −10.3°C and 10.6 kW in cooling mode at an ambient temperature of 32.3°C. The simulation data were compared with the field demo data using ISO 13256. The results showed that the model data compare well with the demo data both in heating and cooling modes of operation. At a source temperature of 16.7°C, the heat pump lab performance data-based COPc shows 9.9, while demonstration COPc shows 10.3, thus, representing 4.3% relative error. The heat pump source temperature decreased by 4.0°C from 20.9°C to 16.9°C due to ground heat exchanger coupling and resulted in a COPc increase by 13.3% from 8.5 to 9.8. When compared at the design conditions (outside temperature of 32.3°C), the TRSNYS model overestimated the demonstration site data by 12%, 9.3 vs. 8.1 kW with power consumption of 3.1 vs. 2.2 kW. The hybrid polygeneration system power consumption decreased by 1.2 kW when ambient temperature decreased from 35°C to 25°C.


Sign in / Sign up

Export Citation Format

Share Document