scholarly journals Performance Assessment of Oil-Immersed Cellulose Insulator Materials Using Time–Domain Spectroscopy under Varying Temperature and Humidity Conditions

Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4426
Author(s):  
Benhui Lai ◽  
Shichang Yang ◽  
Heng Zhang ◽  
Yiyi Zhang ◽  
Xianhao Fan ◽  
...  

The measurement of polarization and depolarization currents (PDC) based on time–domain response is an effective method for state assessment of cellulose insulation material in oil-immersed electrical equipment. However, the versatility of the data obtained at different temperatures is limited because of the temperature dependence of the PDC. In this respect, the universal conversion of PDC data at different temperatures is an essential aspect to improve the accuracy of the determination of insulating properties of cellulose materials immersed in the oil. Thus, an innovative temperature conversion method based on polarization time-varying current (PTC, obtained by multiplying the polarization current and time) is proposed in this article. In the current work, the PTC data at different temperatures are obtained from the oil-immersed cellulose pressboards with different moisture. Afterwards, the functional model based on the power series theory is used to simulate the PTC data, through which the coefficients of the power series are found related to the test temperature of the PTC and the moisture content (mc%) of the oil-immersed cellulose pressboards. Furthermore, the functional relationship among moisture, test temperatures, and the feature parameter calculated by these coefficients is established. Thus, the PTC data at various temperatures can be calculated by the established function. The potential application ability of the proposed method is verified by comparing the calculated results with the measured results obtained from the various samples.

1981 ◽  
Vol 4 (3) ◽  
pp. 615-623
Author(s):  
Sudhangshu B. Karmakar

This paper illustrates by means of a simple example a new approach for the determination of the time domain response of a class of nonlinear systems. The system under investigation is assumed to be described by a nonlinear differential equation with forcing term. The response of the system is first obtained in terms of the input in the form of a Volterra functional expansion. Each of the components in the expansion is first transformed into a multidimensional frequency domain and then to a single dimensional frequency domain by the technique of association of variables. By taking into consideration the conditions for the rapid convergence of the functional expansion the response of the system in the frequency domain can effectively be obtained by taking only the first few terms of the expansion. Time domain response is then found by inverse Laplace transform.


Polymers ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 143 ◽  
Author(s):  
Hanbo Zheng ◽  
Benhui Lai ◽  
Yiyi Zhang ◽  
Jiefeng Liu ◽  
Shichang Yang

Depending on the study of the master curve technique, a temperature correction model for the polarization current of transformer polymer (cellulose) insulation, considering the effects of both moisture content (mc%) and temperature is proposed. In the current work, the shift factors of polarization current curves of samples with various moisture contents are extracted at different temperatures. Then, the variation law among the shift factor, test temperature, and moisture content are studied so as to establish the corresponding functional relationship. The findings reveal that the modified model derived from the above functional relationship could be employed to perform the temperature correction of oil-immersed polymer samples with various insulation states. Therefore, the proposed temperature correction model in this paper will promote the state assessment of the field transformer polymer insulation.


Geophysics ◽  
1989 ◽  
Vol 54 (12) ◽  
pp. 1655-1656 ◽  
Author(s):  
Richard Smith

Flis et al. provide useful insight into the time‐domain response of three‐dimensional polarizable bodies; however, their inference that negative transients are caused by a polarization current which reverses direction disagrees with the previously published theoretical results of Smith et al. (1988) and Smith and West (1988), who found that the polarization current is always negative (provided that the chargeability m and charging current are positive).


1985 ◽  
Vol 54 (02) ◽  
pp. 533-538 ◽  
Author(s):  
Wilfried Thiel ◽  
Ulrich Delvos ◽  
Gert Müller-Berghaus

SummaryA quantitative determination of soluble fibrin in plasma was carried out by affinity chromatography. For this purpose, desAA-fibrin and fibrinogen immobilized on Sepharose 4B were used at the stationary side whereas batroxobin-induced 125I-desAA-fibrin or thrombin-induced 125I-desAABB-fibrin mixed with plasma containing 131I-fibrinogen represented the fluid phase. The binding characteristics of these mixtures to the immobilized proteins were compared at 20° C and 37° C. Complete binding of both types of fibrin to the immobilized desAA-fibrin was always seen at 20° C as well as at 37° C. However, binding of soluble fibrin was accompanied by substantial binding of fibrinogen that was more pronounced at 20° C. Striking differences depending on the temperature at which the affinity chromatography was carried out, were documented for the fibrinogen-fibrin interaction. At 20° C more than 90% of the applied desAA-fibrin was bound to the immobilized fibrinogen whereas at 37° C only a mean of 17% were retained at the fibrinogen-Sepharose column. An opposite finding with regard to the tested temperature was made with the desAABB-fibrin. Nearly complete binding to insolubilized fibrinogen was found at 37° C (95%) but only 58% of the desAABB-fibrin were bound at 20° C. The binding patterns did not change when the experiments were performed in the presence of calcium ions. The opposite behaviour of the two types of soluble fibrin to immobilized fibrinogen at the different temperatures, together with the substantial binding of fibrinogen in the presence of soluble fibrin to insolubilized fibrin in every setting tested, devaluates affinity chromatography as a tool in the quantitative assessment of soluble fibrin in patients’ plasma.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1948
Author(s):  
Chenmeng Zhang ◽  
Kailin Zhao ◽  
Shijun Xie ◽  
Can Hu ◽  
Yu Zhang ◽  
...  

Power capacitors suffer multiple impulse voltages during their lifetime. With the multiple impulse voltage aging, the internal insulation, oil-film dielectric may deteriorate and even fail in the early stage, which is called accumulative effect. Hence, the time-domain dielectric response of oil-film dielectric with multiple impulse voltage aging is studied in this paper. At first, the procedure of the preparation of the tested samples were introduced. Secondly, an aging platform, impulse voltage generator was built to test the accumulative effect of capacitor under multiple impulse voltage. Then, a device was used to test the time-domain dielectric response (polarization depolarization current, PDC) of oil-film dielectric in different aging states. And finally, according to the PDC data, extended Debye model and characteristic parameters were obtained by matrix pencil algorithm identification. The results indicated that with the increase of impulse voltage times, the time-domain dielectric response of oil-film dielectric changed accordingly. The polarization current curve moved up gradually, the insulation resistance decreased when subjected to the repeated impulses. In frequency domain, the frequency spectrum of tan δ changed along with the impulse accumulation aging, especially at low frequency. At last, combined with the aging mechanism of oil-film dielectric under multiple impulse voltage, the test results were discussed.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3013
Author(s):  
Leszek Czechowski

The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis® System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature.


Sign in / Sign up

Export Citation Format

Share Document