scholarly journals Calculating the Interface Flow Limits for the Expanded Use of High-Voltage Direct Current in Power Systems

Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2863
Author(s):  
Sangwook Han

Although loads are increasingly becoming concentrated in metropolitan areas, power generation has decreased in metropolitan areas and increased in nonmetropolitan areas; hence, power transmission must occur through interface lines. To achieve this, additional transmission lines must be secured because the existing interface lines have reached their large-scale power transmission limits. The Korea Electric Power Corporation has installed many high-voltage direct current lines, thereby impacting the determination of interface power flow limits. These serve as the basis for system operations. However, knowledge of operating high-voltage direct current lines as a simple transmission line in a single power system is lacking. The effects of high-voltage direct current and its related parameters for interface flow limit analysis remain unclear. Furthermore, whether high-voltage direct current should be included in the selection of the interface lines that serve as the basis for interface flow remains unclear. In addition, whether the high-voltage direct current line faults should be included in the contingency list for determining the interface flow limits has not been considered. Additionally, it has not been determined whether to operate the DC tap when performing the simulation This study addresses these issues and determines the conditions that are necessary for determining the interface flow limits when a high-voltage direct current transmission facility has been installed in a land power system. The results conclude how to reflect the above conditions reasonably when performing the interface flow limit analysis on a system that includes the HVDC lines.

Author(s):  
Prechanon Kumkratug

This paper presents the method of evaluating transient stability of large scale power system equipped with multi-terminal high voltage direct current (MTDC). The power system including synchronous machine, transmission network, and HVDC is based on the concepts of stability mode. In addition, various techniques to reduce the simulation time are systematically applied. The proposed method helps us to access the transient stability of the system with MTDC in the much simpler way. The verification of the methods is tested on 20 generators in an IEEE 118-bus system under various cases.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 474
Author(s):  
Junxi Wang ◽  
Qi Jia ◽  
Gangui Yan ◽  
Kan Liu ◽  
Dan Wang

With the development of large-scale new energy, the wind–thermal bundled system transmitted via high-voltage direct current (HVDC) has become the main method to solve the problem of wind power consumption. At the same time, the problem of subsynchronous oscillation among wind power generators, high-voltage direct current (HVDC), and synchronous generators (SGs) has become increasingly prominent. According to the dynamic interaction among doubly fed induction generators (DFIGs), HVDC, and SGs, a linearization model of DFIGs and SGs transmitted via HVDC is established, and the influence of the electromagnetic transient of wind turbines and HVDC on the electromechanical transient processes of SGs is studied. Using the method of additional excitation signal injection, the influence of the main factors of DFIG on the damping characteristics of each torsional mode of SG is analyzed, including control parameters and operation conditions when the capacity of HVDC is fixed. The mechanism of the negative damping torsional of SGs is identified. A time-domain simulation model is built in Electromagnetic Transients including DC/Power Systems Computer Aided Design (EMTDC/PSCAD) to verify the correctness and effectiveness of the theoretical analysis.


2021 ◽  
Vol 196 ◽  
pp. 107260
Author(s):  
Bo Chen ◽  
Tiebing Lu ◽  
Bin Bai ◽  
Nanxuan Shen ◽  
Yuanhang Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document