In Poland, various solar collector systems are used; among them, the most popular are flat plate collectors (FPCs) and evacuated tube collectors (ETCs). The work presents two installations located at a distance of 80 km apart, working in similar external conditions. One of them contains 120 flat plate collectors and works for the preparation of hot water in a swimming pool building; the second one consists of 32 evacuated tube collectors with a heat pipe and supports the preparation of domestic hot water for a multi-family house. During the comparison of the two quite large solar installations, it was confirmed that the use of evacuated tube solar collectors shows a much better solar energy productivity than flat plate collectors for the absorber area. Higher heat solar gains (by 7.9%) were also observed in the case of the gross collector area. The advantages of evacuated tube collectors are observed mainly during colder periods, which allows for a steadier thermal energy production.

Author(s):  
Andy Walker ◽  
Fariborz Mahjouri ◽  
Robert Stiteler

This paper describes design, simulation, construction and measured initial performance of a solar water heating system (360 Evacuated Heat-Pipe Collector tubes, 54 m2 gross area, 36 m2 net absorber area) installed at the top of the hot water recirculation loop in the Social Security Mid-Atlantic Center in Philadelphia. Water returning to the hot water storage tank is heated by the solar array when solar energy is available. This new approach, as opposed to the more conventional approach of preheating incoming water, is made possible by the thermal diode effect of heat pipes and low heat loss from evacuated tube solar collectors. The simplicity of this approach and its low installation costs makes the deployment of solar energy in existing commercial buildings more attractive, especially where the roof is far removed from the water heating system, which is often in the basement. Initial observed performance of the system is reported. Hourly simulation estimates annual energy delivery of 111 GJ/year of solar heat and that the annual efficiency (based on the 54 m2 gross area) of the solar collectors is 41%, and that of the entire system including parasitic pump power, heat loss due to freeze protection, and heat loss from connecting piping is 34%. Annual average collector efficiency based on a net aperture area of 36 m2 is 61.5% according to the hourly simulation.


2021 ◽  
Author(s):  
Kamyar Tanha

This thesis is focused on the performance of the two SDHW systems of the sustainable Archetype houses in Vaughan, Ontario with daily hot water consumption of 225 litres. The first system consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR. The second SDHW system consists of an evacuated tube collector, an electric tank and a DWHR. The experimental results showed that the DWHRs were capable of an annual heat recovery of 789 kWh. The flat plate and evacuated tube collectors had an annual thermal energy output of 2038 kWh and 1383 kWh. The systems were also modeled in TRNSYS and validated with the experimental results. The simulated results showed that Edmonton has the highest annual energy consumption of 3763.4 kWh and 2852.9 kWh by gas boiler and electric tank and that the solar thermal collectors and DWHRs are most beneficial in Edmonton.


2014 ◽  
Vol 521 ◽  
pp. 539-542
Author(s):  
Da Yu Zheng ◽  
Juan Zheng ◽  
Xiang Yi Guan ◽  
Jia Zheng ◽  
Yi Ming Zhang

To cover the main contributions and developments in solar thermal collectors through focusing on materials, heat transfer characteristics and manufacturing challenges. A range of published papers and internet research including research work on various solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube) were used. Evaluation of solar collectors performance is critiqued to aid solar technologies make the transition into a specific dominant solar collector. The sources are sorted into sections: finding an academic job, general advice, teaching, research and publishing, tenure and organizations. Provides information about types of solar thermal collectors, indicating what can be added by using evacuated tube collectors instead of flat plate collectors and what can be added by using heat pipe collectors instead of evacuated tubes. Focusing only on three types of solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube). Useful source of information for consultancy and impartial advice for graduate students planning to do research in solar thermal technologies. This paper fulfils identified information about materials and heat transfer properties of materials and manufacturing challenges of these three solar thermal collectors. Describes some changes made to improve the environment which have had unforeseen and adverse effects on safety and the reasons why we need more case histories. Also discusses the reasons why there are no permanent solutions to safety problems and the reasons why senior managers should become more involved in safety problems.


Author(s):  
Enrico Zambolin ◽  
Davide Del Col ◽  
Andrea Padovan

New comparative tests on different types of solar collectors are presented in this paper. Tests have been performed at the solar energy conversion laboratory of the University of Padova. Two standard glazed flat plate collectors and one evacuated tube collector are installed in parallel; the evacuated collector is a direct flow through type with external CPC (compound parabolic concentrator) reflectors. The present test rig allows to make measurements on the flat plate, on the evacuated collector or on both simultaneously, by simply acting on the valves to modify the circuit. In this paper measurements of the performance of the evacuated tube collector and flat plate collectors working at the same conditions are reported. Efficiency in stationary conditions is measured following the standard EN 12975-2 [1] and it is compared with the input/output curves measured for an entire day. The main purpose of the present work is to characterize and to compare the daily energy performance of the two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling).


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Brahim Taoufik ◽  
Mhiri Foued ◽  
Jemni Abdelmajid

The use of heat pipes in solar collectors offers several advantages regarding flexibility in operation and application, as they are very efficient in transporting heat even under a small temperature difference. Compared with other systems powered by evacuated tube collectors or flat plate solar collectors using a wickless heat pipe, little attention has been paid to a flat plate solar collectors wick assisted heat pipe. In this paper an analytical model based on energy balance equations assuming a steady state condition was developed to evaluate the thermal efficiency of a flat plate wick assisted heat pipe solar collector. Parameters which affect the collector efficiency are identified, such as tube spacing distance, gap spacing between the absorber plate and the glazing cover, and the emissivity of the absorber plate. The results reflect the contribution and significance of each of these parameters to the collector overall heat loss coefficients. Three heat pipe working fluids are examined and results show that acetone performs better than methanol and ethanol.


2021 ◽  
Author(s):  
Kamyar Tanha

This thesis is focused on the performance of the two SDHW systems of the sustainable Archetype houses in Vaughan, Ontario with daily hot water consumption of 225 litres. The first system consists of a flat plate solar thermal collector in conjunction with a gas boiler and a DWHR. The second SDHW system consists of an evacuated tube collector, an electric tank and a DWHR. The experimental results showed that the DWHRs were capable of an annual heat recovery of 789 kWh. The flat plate and evacuated tube collectors had an annual thermal energy output of 2038 kWh and 1383 kWh. The systems were also modeled in TRNSYS and validated with the experimental results. The simulated results showed that Edmonton has the highest annual energy consumption of 3763.4 kWh and 2852.9 kWh by gas boiler and electric tank and that the solar thermal collectors and DWHRs are most beneficial in Edmonton.


2010 ◽  
Vol 171-172 ◽  
pp. 486-489
Author(s):  
Jie Li

To cover the main contributions and developments in solar thermal collectors through focusing on materials, heat transfer characteristics and manufacturing challenges. A range of published papers and internet research including research work on various solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube) were used. Evaluation of solar collectors performance is critiqued to aid solar technologies make the transition into a specific dominant solar collector. The sources are sorted into sections: finding an academic job, general advice, teaching, research and publishing, tenure and organizations. Provides information about types of solar thermal collectors, indicating what can be added by using evacuated tube collectors instead of flat plate collectors and what can be added by using heat pipe collectors instead of evacuated tubes. Focusing only on three types of solar thermal collectors (flat plate, evacuated tubes, and heat pipe tube). Useful source of information for consultancy and impartial advice for graduate students planning to do research in solar thermal technologies. This paper fulfils identified information about materials and heat transfer properties of materials and manufacturing challenges of these three solar thermal collectors.