scholarly journals Investigating the System Behaviors of a 10 kW Organic Rankine Cycle (ORC) Prototype Using Plunger Pump and Centrifugal Pump

Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1141 ◽  
Author(s):  
Xin Wang ◽  
Yong-qiang Feng ◽  
Tzu-Chen Hung ◽  
Zhi-xia He ◽  
Chih-Hung Lin ◽  
...  

Based on a 10-kW organic Rankine cycle (ORC) experimental prototype, the system behaviors using a plunger pump and centrifugal pump have been investigated. The heat input is in the range of 45 kW to 82 kW. The temperature utilization rate is defined to appraise heat source utilization. The detailed components’ behaviors with the varying heat input are discussed, while the system generating efficiency is examined. The exergy destruction for the four components is addressed finally. Results indicated that the centrifugal pump owns a relatively higher mass flow rate and pump isentropic efficiency, but more power consumption than the plunger pump. The evaporator pressure drops are in the range of 0.45–0.65 bar, demonstrating that the pressure drop should be considered for the ORC simulation. The electrical power has a small difference using a plunger pump and a centrifugal pump, indicating that the electric power is insensitive on the pump types. The system generating efficiency for the plunger pump is approximately 3.63%, which is 12.51% higher than that of the centrifugal pump. The exergy destruction for the evaporator, expander, and condenser is almost 30%, indicating that enhancing the temperature matching between the system and the heat (cold) source is a way to improve the system performance.

Author(s):  
Fahad A. Al-Sulaiman ◽  
Feridun Hamdullahpur ◽  
Ibrahim Dincer

In this paper, energy and exergy analyses of a trigeneration system based on an organic Rankine cycle (ORC) and a biomass combustor are presented. This trigeneration system consists of a biomass combustor to provide heat input to the ORC, an ORC for power production, a single-effect absorption chiller for cooling process and a heat exchanger for heating process. The system is designed to produce around 500 kW of electricity. In this study, four cases are considered, namely, electrical-power, cooling-cogeneration, heating-cogeneration and trigeneration cases. The effects of changing ORC pump inlet temperature and turbine inlet pressure on different key parameters have been examined to evaluate the performance of the trigeneration system. These parameters are energy and exergy efficiencies, electrical to cooling ratio and electrical to heating ratio. Moreover, exergy destruction analysis is presented to show the main sources of exergy destruction and the contribution of each source to the exergy destruction. The study shows that there are significant improvements in energy and exergy efficiencies when trigeneration is used as compared to electrical power. The results show that the maximum efficiencies for the cases considered in this study are as follows: 14.0% for electrical power, 17.0% for cooling cogeneration, 87.0% for heating cogeneration and 89.0% for trigeneration. On other hand, the maximum exergy efficiency of the ORC is 13.0% while the maximum exergy efficiency of the trigeneration system is 28.0%. In addition, this study reveals that the main sources of exergy destruction are the biomass combustor and ORC evaporator.


Author(s):  
Wahiba Yaïci ◽  
Evgueniy Entchev

Abstract A continued increase in both energy demand and greenhouse gas emissions (GHGs) call for utilising energy sources effectively. In comparison with traditional energy set-ups, micro-combined heat and power (micro-CHP) generation is viewed as an effective alternative; the aforementioned system’s definite electrical and thermal generation may be attributed to an augmented energy efficiency, decreased capacity as well as GHGs percentage. In this regard, organic Rankine cycle (ORC) has gained increasing recognition as a system, which is capable for generating electrical power from solar-based, waste heat, or thermal energy sources of a lower quality, for instance, below 120 °C. This study focuses on investigating a solar-based micro-CHP system’s performance for use in residential buildings through utilising a regenerative ORC. The analysis will focus on modelling and simulation as well as optimisation of operating condition of several working fluids (WFs) in ORC in order to use a heat source with low-temperature derived from solar thermal collectors for both heat and power generation. A parametric study has been carried out in detail for analysing the effects of different WFs at varying temperatures and flowrates from hot and cold sources on system performance. Significant changes were revealed in the study’s outcomes regarding performance including efficiency as well as power obtained from the expander and generator, taking into account the different temperatures of hot and cold sources for each WF. Work extraction carried out by the expander and electrical power had a range suitable for residential building applications; this range was 0.5–5 kWe with up to 60% electrical isentropic efficiency and up to 8% cycle efficiency for 50–120 °C temperature from a hot source. The operation of WFs will occur in the hot source temperature range, allowing the usage of either solar flat plate or evacuated tube collectors.


2019 ◽  
Vol 9 (23) ◽  
pp. 5028 ◽  
Author(s):  
Pektezel ◽  
Acar

This paper presents energy and exergy analysis of two vapor compression refrigeration cycles powered by organic Rankine cycle. Refrigeration cycle of combined system was designed with single and dual evaporators. R134a, R1234ze(E), R227ea, and R600a fluids were used as working fluids in combined systems. Influences of different parameters such as evaporator, condenser, boiler temperatures, and turbine and compressor isentropic efficiencies on COPsys and ƞex,sys were analyzed. Second law efficiency, degree of thermodynamic perfection, exergy destruction rate, and exergy destruction ratio were detected for each component in systems. R600a was determined as the most efficient working fluid for proposed systems. Both COPsys and ƞex,sys of combined ORC-single evaporator VCR cycle was detected to be higher than the system with dual evaporator.


Clean Energy ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 476-491
Author(s):  
Yunis Khan ◽  
Radhey Shyam Mishra

Abstract In this study, a parametric analysis was performed of a supercritical organic Rankine cycle driven by solar parabolic trough collectors (PTCs) coupled with a vapour-compression refrigeration cycle simultaneously for cooling and power production. Thermal efficiency, exergy efficiency, exergy destruction and the coefficient of performance of the cogeneration system were considered to be performance parameters. A computer program was developed in engineering equation-solver software for analysis. Influences of the PTC design parameters (solar irradiation, solar-beam incidence angle and velocity of the heat-transfer fluid in the absorber tube), turbine inlet pressure, condenser and evaporator temperature on system performance were discussed. Furthermore, the performance of the cogeneration system was also compared with and without PTCs. It was concluded that it was necessary to design the PTCs carefully in order to achieve better cogeneration performance. The highest values of exergy efficiency, thermal efficiency and exergy destruction of the cogeneration system were 92.9%, 51.13% and 1437 kW, respectively, at 0.95 kW/m2 of solar irradiation based on working fluid R227ea, but the highest coefficient of performance was found to be 2.278 on the basis of working fluid R134a. It was also obtained from the results that PTCs accounted for 76.32% of the total exergy destruction of the overall system and the cogeneration system performed well without considering solar performance.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3032 ◽  
Author(s):  
Xiaoli Yu ◽  
Zhi Li ◽  
Yiji Lu ◽  
Rui Huang ◽  
Anthony Roskilly

An innovative cascade cycle combining a trilateral cycle and an organic Rankine cycle (TLC-ORC) system is proposed in this paper. The proposed TLC-ORC system aims at obtaining better performance of temperature matching between working fluid and heat source, leading to better overall system performance than that of the conventional dual-loop ORC system. The proposed cascade cycle adopts TLC to replace the High-Temperature (HT) cycle of the conventional dual-loop ORC system. The comprehensive comparisons between the conventional dual-loop ORC and the proposed TLC-ORC system have been conducted using the first and second law analysis. Effects of evaporating temperature for HT and Low-Temperature (LT) cycle, as well as different HT and LT working fluids, are systematically investigated. The comparisons of exergy destruction and exergy efficiency of each component in the two systems have been studied. Results illustrate that the maximum net power output, thermal efficiency, and exergy efficiency of a conventional dual-loop ORC are 8.8 kW, 18.7%, and 50.0%, respectively, obtained by the system using cyclohexane as HT working fluid at THT,evap = 470 K and TLT,evap = 343 K. While for the TLC-ORC, the corresponding values are 11.8 kW, 25.0%, and 65.6%, obtained by the system using toluene as a HT working fluid at THT,evap = 470 K and TLT,evap = 343 K, which are 34.1%, 33.7%, and 31.2% higher than that of a conventional dual-loop ORC.


Author(s):  
Maoqing Li ◽  
Jiangfeng Wang ◽  
Lin Gao ◽  
Xiaoqiang Niu ◽  
Yiping Dai

Due to environmental constraints, the Organic Rankine Cycle (ORC) is widely used to generate electricity from low grade heat sources. In ORC processes, the working fluid is an organic substance, which has a better thermodynamic performance than water for low grade heat recovery. The design of the turbine which is the key component in the ORC system strongly depends on the operating conditions and on the scale of the facility. This paper presents an experimental study on a prototype of an axial-flow turbine integrated into a regenerative ORC system with R123 as working fluid. The power output is 10kW scale, and the single-stage turbine is selected. The turbine is specially designed and manufactured, and a generator is connected to the turbine directly. In the experiment, the turbine is tested under different inlet pressure conditions (0.6–1.5MPa), different inlet temperature conditions (80–150°C) and different flow rate conditions. The experimental data such as the pressures, temperatures of the turbine inlet and outlet, flow rate, rotational speed, and electrical power generation are analyzed to find their inner relationships. During the test, the turbine rotational speed could reach more than 3010 r/min, while the design rotational speed is 3000 r/min. The isentropic efficiency of the turbine could reach 53%. The maximum electrical power generated by the turbine-generator is 6.57KW. From the test data the peak value of the temperature difference between the inlet and the outlet of the turbine is 53 °C, and the expansion ratio reaches about 11. The computational fluid dynamics (CFD) solvers is also used to analyze the performance of the turbine. The distributions of the pressure, Mach number, and static entropy in the turbine flow passage component are examined and the reasons are also obtained. This study reveals the relationships between the performance of the axial-flow turbine and its inlet and outlet vapor conditions. The experiment results and the CFD results lay a foundation for using this type turbine in the ORC systems which product electrical power from a few KW to MW.


2016 ◽  
Vol 1 ◽  
pp. 13 ◽  
Author(s):  
Mahdi Hatf Kadhum Aboaltabooq ◽  
Tudor Prisecaru ◽  
Horatiu Pop ◽  
Valentin Apostol ◽  
Malina Prisecaru ◽  
...  