scholarly journals Improved Faulted Phase Selection Algorithm for Distance Protection under High Penetration of Renewable Energies

Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 558
Author(s):  
Eduardo Martínez Carrasco ◽  
María Paz Comech Moreno ◽  
María Teresa Villén Martínez ◽  
Samuel Borroy Vicente

The high penetration of renewable energies will affect the performance of present protection algorithms due to fault current injection from generators based on power electronics. This paper explains the process followed for analyzing this effect on distance protection and the development of a new algorithm that improves its performance in such a scenario. First of all, four commercial protection relays were tested before fault current contribution from photovoltaic system and full converter wind turbines using the hardware in the loop technique. The analysis of results obtained, jointly with a theoretical analysis based on commonly used protection strategy of superimposed quantities, lead to a conclusion about the cause of observed wrong behaviors of present protection algorithms under a high penetration of renewables. According to these conclusions, a new algorithm has been developed to improve the detection of faulted phase selection and directionality on distance protection under a short circuit current fed by renewable energy sources.

Processes ◽  
2019 ◽  
Vol 8 (1) ◽  
pp. 34 ◽  
Author(s):  
Shijie Cui ◽  
Peng Zeng ◽  
Chunhe Song ◽  
Zhongfeng Wang

With the decentralization of the electricity market and the plea for a carbon-neutral ecosystem, more and more distributed generation (DG) has been incorporated in the power distribution grid, which is then known as active distribution network (ADN). The addition of DGs causes numerous control and protection confronts to the traditional distribution network. For instance, two-way power flow, small fault current, persistent fluctuation of generation and demand, and uncertainty of renewable energy sources (RESs). These problems are more challenging when the distribution network hosts many converter-coupled DGs. Hence, the traditional protection schemes and relaying methods are inadequate to protect ADNs against short-circuit faults and disturbances. We propose a robust communication-assisted fault protection technique for safely operating ADNs with high penetration of converter-coupled DGs. The proposed technique is realizable by employing digital relays available in the recent market and it aims to protect low-voltage (LV) ADNs. It also includes secondary protection that can be enabled when the communication facility or protection equipment fails to operate. In addition, this study provides the detail configuration of the digital relay that enables the devised protection technique. Several enhancements are derived, as alternative technique for the traditional overcurrent protection approach, to detect small fault current and high-impedance fault (HIF). A number of simulations are performed with the complete model of a real ADN, in Shenyang, China, employing the PSCAD software platform. Various cases, fault types and locations are considered for verifying the efficacy of the devised technique and the enabling digital relay. The obtained simulation findings verify the proposed protection technique is effective and reliable in protecting ADNs against various fault types that can occur at different locations.


2012 ◽  
Vol 260-261 ◽  
pp. 257-262
Author(s):  
Feng Ting Li ◽  
Chang Sheng Su

In allusion to the problems of convention current protection when it was used to collect circuit of wind farm, the relay protection should consider the short-circuit current of wind generators; The principle of adaptive current protection was described, the fault current and attenuation characteristic of asynchronous wind generator was studied, the scheme of adaptive current protection was proposed for wind farm operation. Taking PSCAD/EMTDC as the platform, simulation and record the voltage and current sample-data of different wind farm operation which can guarantee high sensitivity phase selection, the high accuracy wind generators impedance measure method based on FFT filter DC component is presented , and using MATLAB program achieved the scheme of adaptive current protection. Simulation results demonstrate that collect circuit adaptive current protection is adaptive wind farm operation model, and enhance the operation benefit of wind farm.


2020 ◽  
Author(s):  
Alexandre Bitencourt ◽  
Daniel H. N. Dias ◽  
Bruno W. França ◽  
Felipe Sass ◽  
Guilherme G. Sotelo

The increase in demand for electric power and the insertion of a distributed generation led to the rise of the short-circuit current in substations. Most of these Brazilian substations were designed decades ago, because of that their equipment may not support the new short-circuit current levels. To protect the installed equipment and avoid excessive costs replacing old devices, it is possible to install Fault Current Limiters (FCLs). This document is a report from an R&D project that evaluated FCL topologies considering real parameters in simulation from used equipment, concluding that the selected FCL topologies accomplished their technical objective. However, before implementing these topologies in the distribution system, one should consider the technical and economic feasibility of using semiconductor switching devices.


2019 ◽  
Vol 9 (9) ◽  
pp. 1737 ◽  
Author(s):  
Bin Jiang ◽  
Yanfeng Gong

A modular multilevel converter based high-voltage DC (MMC-HVDC) system has been the most promising topology for HVDC. A reclosing scheme is usually configured because temporary faults often occur on transmission lines especially when overhead lines are used, which often brings about an overcurrent problem. In this paper, a new fault current limiter (FCL) based on reclosing current limiting resistance (RCLR) is proposed to solve the overcurrent problem during the reclosing process. Firstly, a mesh current method (MCM) based short-circuit current calculation method is newly proposed to solve the fault current calculation of a loop MMC-HVDC grid. Then the method to calculate the RCLR is proposed based on the arm current to limit the arm currents to a specified value during the reclosing process. Finally, a three-terminal loop MMC-HVDC test grid is constructed in the widely used electromagnetic transient simulation software PSCAD/EMTDC and the simulations prove the effectiveness of the proposed strategy.


2013 ◽  
Vol 389 ◽  
pp. 1089-1095
Author(s):  
Jun Zhen Peng ◽  
Kun Nan Cao ◽  
Da Da Wang ◽  
Meng Song ◽  
Nan Nan Hu ◽  
...  

As one of the most applicable to high-voltage network superconducting fault current limiterSCFCL(saturated core superconducting fault current limiter) ,which use of core saturation properties can be achieved the current-limiting function without delay ,will be the most widely applied in the future,By analyzing the working principle of SCFCL,this paper use of PSCAD and finite element analysis software Ansoft to build the 500kV\/3150A grade SCFCL model and accurate calculation coil self-inductance and mutual inductance, the harmonic of each size and analyzed its Impedance characteristic on the different external parameters,The results show that SCFCL has a excellent performance for high voltage power network short-circuit current limitation, and provides important reference for design.


2012 ◽  
Vol 260-261 ◽  
pp. 525-531 ◽  
Author(s):  
Salman Badkubi

This paper presents the comprehensive implementation of Distributed Static Series Compensator (DSSC) to limit the fault currents in power systems. This is the first time that the limitation of fault currents with D-FACTS devices is addressed. DSSC is one of the D-FACTS families whichoperate in a similar manner as Static Synchronous Series Compensator (SSSC) but in smaller size, lower price and more capability. The effectiveness of the DSSC in fault current limitation is investigated through the series voltage effect upon the line. The short circuit current limitation strategy presented here exhibited that besides of the power flow control which is carried out by DSSC; it can also perform this additional function. In the following the potency of the DSSC in reduction of instantaneous voltage dip range during fault current limiting mode is clarified. Furthermore, it is disclosed that with performing more DSSC in the power system, the entire system voltage dip will be improved. In order to validate the claims, computer simulations using PSCAD/EMTDC are exploited.


Author(s):  
Đoàn Tự Do ◽  
Lê Bửu Toàn ◽  
Lê Thị Tịnh Minh

Nowadays, with consecutive development of the power system, not only the scale of the grid is expanded but also many technical problems exist. One of the most important problems is the exceeding short circuit current in the power grid, this value exceeds out of the regulation’s range as well as breaking capacity of the protection devices. In this paper, a fault current limiter (FCL) device is introduced as a solution; it works as a high impedance in short circuit cases and low impedance in normally case. This paper simulates the fault current limiter transformer type in MATLAB/SIMULINK, the effect of FCLT’s parameters to short circuit reduction is given in the results. Application of FCLT in reality network also is presented with markable results of short circuit reduction in Ho Chi Minh Power Corporation‘s distribution system.