scholarly journals CFD Analysis of Falling Film Hydrodynamics for a Lithium Bromide (LiBr) Solution over a Horizontal Tube

Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 307 ◽  
Author(s):  
Furqan Tahir ◽  
Abdelnasser Mabrouk ◽  
Muammer Koç

Falling film evaporators are used in applications where high heat transfer coefficients are required for low liquid load and temperature difference. One such application is the lithium bromide (LiBr)-based absorber and generator. The concentration of the aqueous LiBr solution changes within the absorber and generator because of evaporation and vapor absorption. This causes the thermophysical properties to differ and affects the film distribution, heat, and mass transfer mechanisms. For thermal performance improvement of LiBr-based falling film evaporators, in-depth analysis at the micro level is required for film distribution and hydrodynamics. In this work, a 2D numerical model was constructed using the commercial CFD software Ansys Fluent v18.0. The influence of the liquid load corresponding to droplet and jet mode, and the concentration, on film hydrodynamics was examined. It was found that the jet mode was more stable at a higher concentration of 0.65 with ±0.5% variation compared to lower concentrations. The recirculation was stronger at a low concentration of 0.45 and existed until the angular position (θ) = 10°, whereas at 0.65 concentration it diminished after θ = 5°. The improved heat transfer is expected at lower concentrations due to lower film thickness and thermal resistance, more recirculation, and a higher velocity field.

2018 ◽  
Vol 194 ◽  
pp. 01007
Author(s):  
Maria V. Bartashevich

Mathematical model of conjugated heat and mass transfer in absorption on the entrance region of the semi-infinite liquid film of lithium bromide water solution is investigated for different values of Froude number. The calculations shown that larger values of Froude number corresponds to a smaller thickness of the falling film. It was demonstrated that for large values of the Froude number the heat transfer from the surface is greater than for smaller values.


2006 ◽  
Vol 10 (4) ◽  
pp. 55-61 ◽  
Author(s):  
Zoltan Zavargo ◽  
Aleksandar Jokic ◽  
Bojana Prodanic ◽  
Jasna Grbic ◽  
Rada Jeftic-Mucibabic

General trend of free trade in regional level as well as in the direction of European Union has motivated sugar factories located in Serbia to invest into technologies that are more efficient in order to make their products more competitive at the markets in Europe. The aim of this work was to evaluate effects of falling film plate evaporators on the energy consumption of evaporation plant, as well as to validate performance of this type of evaporators. It was found that this type of evaporator decreased energy requirements and in the same time evaporation process was more effective due to high values of heat transfer coefficients. .


Author(s):  
Tobias Krille ◽  
Stefan Retzko ◽  
Rico Poser ◽  
Jens von Wolfersdorf

Abstract The transient Thermochromic Liquid Crystal (TLC) method is applied to determine the distribution of the local heat transfer coefficients using a configuration with parallel cooling channels at an engine relevant Reynolds number. The rectangular channels with a moderate aspect ratio and a high length-to-diameter ratio are equipped with one-sided oblique ribs with high blockage, which is a promising configuration for turbine near wall cooling applications. In this arrangement, the three inner channels should experience same flow and thermal conditions. Numerical simulations are performed to substantiate this assumption. The symmetric single channels are sprayed with narrowband TLC with various indication temperatures. Multiple experiments were conducted. All start at ambient conditions before the fluid is heated up to several temperatures between 46°C and 73°C. The results show that the determined local heat transfer coefficients and therefore the Nusselt numbers vary significantly for the different experimental conditions especially at locations of high heat transfer coefficient behind the ribs. A simplified procedure with respect to measurement uncertainties is applied to enable an easy and fast valuation on the data quality. This might be used within the data reduction analysis for such experiments directly. The approach is illustrated using the obtained experimental data.


2004 ◽  
Vol 126 (4) ◽  
pp. 528-534 ◽  
Author(s):  
S. B. Sathe ◽  
B. G. Sammakia

The results of a study of a new and unique high-performance air-cooled impingement heat sink are presented. An extensive numerical investigation of the heat sink performance is conducted and is verified by experimental data. The study is relevant to cooling of high-power chips and modules in air-cooled environments and applies to workstations or mainframes. In the study, a rectangular jet impinges on a set of parallel fins and then turns into cross flow. The effects of the fin thickness, gap nozzle width and fin shape on the heat transfer and pressure drop are investigated. It is found that pressure drop is reduced by cutting the fins in the central impingement zone without sacrificing the heat transfer due to a reduction in the extent of the stagnant zone. A combination of fin thicknesses of the order of 0.5 mm and channel gaps of 0.8 mm with appropriate central cutout yielded heat transfer coefficients over 1500 W/m2 K at a pressure drop of less than 100 N/m2, as is typically available in high-end workstations. A detailed study of flow-through heat sinks subject to the same constraints as the impingement heat sink showed that the flow-through heat sink could not achieve the high heat transfer coefficients at a low pressure drop.


Author(s):  
Wei Li ◽  
Xiaoyu Wu ◽  
Zhong Luo

This paper reports an experimental study on falling film evaporation of water on 6-row horizontal configured tube bundles in a vacuum. Three types of configured tubes, Turbo-CAB-19fpi and −26fpi, Korodense, including smooth tubes for reference, were tested in a range of film Reynolds number from about 10 to 110. Results show that as the falling film Reynolds number increases, falling film evaporation goes from tubes partial dryout regime to fully wet regime; the mean heat transfer coefficients reach peak values in the transition point. Turbo-CAB tubes have the best heat transfer enhancement of falling film evaporation in both regimes, but Korodense tubes’ overall performances are better when tubes are fully wet. The inlet temperature of heating water has hardly any effects on the heat transfer, but the evaporation pressure has controversial effects. A correlation with errors within 10% was also developed to predict the heat transfer enhancement capacity.


Author(s):  
O. Manca ◽  
S. Nardini ◽  
D. Ricci

Conventional sources of energy have been depleting at an alarming rate, which makes future sustainable development of energy use very difficult. Thus, heat transfer enhancement technology plays an important role and it has been widely applied to many applications as in refrigeration, automotive, process industry, solar energy heater, etc. Convective heat transfer can be enhanced passively by changing flow geometry, boundary conditions or by increasing thermal conductivity of the fluid. Another possibility for increasing heat transfer with gas is to employ extended surfaces. In this paper a numerical investigation is carried out on forced convection in circular tubes with septa heated by constant fluxes and characterized by different shapes. When gas flows in a tube, septa with one or more openings can be used as fins. Furthermore, when the openings are arranged to give a spiral motion around the cylinder axis wall-fluid contact area increases. As a consequence the presence of the septa may significantly augment pressure drops. The fluid is air and properties are function of temperature. Septa of the same material of the tube are introduced and several shapes and arrangements are analyzed as well as different Reynolds numbers, baffle spacings and heat fluxes applied on the external surface. The investigation is accomplished by means of the commercial code Fluent. A k-e turbulence model is used with enhanced wall treatment options. Results are presented in terms of temperature and velocity fields, local and average heat transfer coefficients, friction factors and pressure drops for different values of heat flux, Reynolds numbers and baffle spacings. The aim of this study is to find the shape and arrangement of septa such to give high heat transfer coefficients and low pressure drops.


Author(s):  
Jessica Sheehan ◽  
Avram Bar-Cohen

Heat transfer to an evaporating refrigerant and/or dielectric liquid in a microgap channel can provide very high heat transfer coefficients and volumetric cooling rates. Recent studies at Maryland have established the dominance of the annular flow regime in such microgap channels and related the observed high-quality peak of an M-shaped heat transfer coefficient curve to the onset of local dryout. The present study utilizes infrared thermography to locate such nascent dryout regions and operating conditions. Data obtained with a 210 micron microgap channel, operated with a mass flux of 195.2 kg/m2-s and heat fluxes of 10.3 to 26 W/cm2 are presented and discussed.


Sign in / Sign up

Export Citation Format

Share Document