scholarly journals Study on DC Breaker Fault Current and Its Limiting Method of Multiterminal Flexible DC Distribution System

Energies ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 859 ◽  
Author(s):  
Jinghan Zhang ◽  
Yuqun Gao ◽  
Fanglei Xiao ◽  
Fang Guo ◽  
Xinwei Li ◽  
...  

The multiterminal flexible DC (MTDC) distribution system has become a hot research topic for its advantages such as new energy load accessibility and high reliability of power supply. However, the fault current during short-circuit faults will be more complicated and serious because of the multiple operating modes and specific converter structure in MTDC distribution system. The high fault current will affect the safety of equipment and system operation. As a result, it is necessary to study the fault current generation mechanism and current limiting method of the DC distribution system. In this paper, the generation mechanism, transient characteristics, and the influencing factors of the fault current in the DC breaker during the short-circuit faults are analyzed by theoretical analysis and simulations separately based on a ±10 kV three-terminal flexible DC distribution system. The current limiting devices are analyzed, and its configuration position and parameter calculation method are proposed. On this basis, the parameters of the current limiting reactor and its effects on each position are analyzed by electromagnetic transient simulations. The current limiting scheme is proposed and its reliability is verified. The study results can provide some reference for overcurrent analysis and current limiting measures of the multiterminal DC distribution system.

2021 ◽  
Vol 256 ◽  
pp. 01032
Author(s):  
Zhenyu Wang ◽  
Shouxiang Wang ◽  
Qi Liu ◽  
Chunyu Zhang ◽  
Qianyu Zhao ◽  
...  

With the development of power electronic technology, flexible DC distribution system has gradually become a research hotspot. Pole-to-pole short circuit fault is the most serious fault type in DC distribution system. When pole-to-pole short circuit fault occurs in DC side, it will produce a large fault current, which will cause serious harm to DC distribution system. Therefore, it is urgent to install current limiting reactor to limit fault over-current. Aiming at the DC distribution system based on half bridge MMC, this paper analyses the fault mechanism and fault characteristics of pole-to-pole short circuit fault, studies the current limiting effect of the installation position and capacity of current limiting reactor on fault current, and carries out simulation verification in PSCAD / EMTDC platform. The analysis and simulation results show that installing a current limiting reactor at the outlet of the DC side can reduce the peak value of capacitor discharge current, and installing a current limiting reactor at the outlet of the AC side can reduce the overall amplitude of fault current.


Energies ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 3159 ◽  
Author(s):  
Gao ◽  
Han ◽  
Zhang ◽  
Xiao ◽  
Zhao ◽  
...  

The DC (Direct Current) distribution system based on the voltage source converter (VSC-DC) has become a research hotspot due to its various advantages. There are many plug-in devices in the VSC-DC distribution system, which may be damaged by the fault current. Therefore, studying the fault current characteristics and current limiting method is one of the key methods to ensure the safe and stable operation of the VSC-DC distribution system. Based on theoretical analysis and simulation calculations, this paper studies the causes, influencing factors, and current limiting methods of the fault current when the pole-to-pole fault occurs at the line side of plug-in devices in a ±10 kV VSC-DC distribution system. Firstly, based on the system topology, the decisive fault condition of fault current and the design principle of current limiting reactor value are analyzed. Secondly, the theoretical calculation methods of fault current and current limiting reactor value which satisfies the breaking capacity of DC circuit breaker are proposed. Finally, the accuracy of theoretical calculation methods is verified by simulation in PSCAD/EMTDC (Power Systems Computer Aided Design/ Electromagnetic Transients including DC). The research results could provide the theoretical calculation methods of the fault current and the current limiting reactor value of plug-in devices in the ±10 kV VSC-DC distribution system.


2020 ◽  
Author(s):  
Alexandre Bitencourt ◽  
Daniel H. N. Dias ◽  
Bruno W. França ◽  
Felipe Sass ◽  
Guilherme G. Sotelo

The increase in demand for electric power and the insertion of a distributed generation led to the rise of the short-circuit current in substations. Most of these Brazilian substations were designed decades ago, because of that their equipment may not support the new short-circuit current levels. To protect the installed equipment and avoid excessive costs replacing old devices, it is possible to install Fault Current Limiters (FCLs). This document is a report from an R&D project that evaluated FCL topologies considering real parameters in simulation from used equipment, concluding that the selected FCL topologies accomplished their technical objective. However, before implementing these topologies in the distribution system, one should consider the technical and economic feasibility of using semiconductor switching devices.


Author(s):  
Saeed Zaman Jamali ◽  
Muhammad Omer Khan ◽  
Syed Basit Ali Bukhari ◽  
Muhammad Mehdi ◽  
Gi-Hyeon Gwon ◽  
...  

2005 ◽  
Vol 426-431 ◽  
pp. 1380-1384
Author(s):  
Hongtian Shao ◽  
Tomoyuki Satoh ◽  
Mitsugi Yamaguchi ◽  
Satoshi Fukui ◽  
Jun Ogawa ◽  
...  

Author(s):  
Đoàn Tự Do ◽  
Lê Bửu Toàn ◽  
Lê Thị Tịnh Minh

Nowadays, with consecutive development of the power system, not only the scale of the grid is expanded but also many technical problems exist. One of the most important problems is the exceeding short circuit current in the power grid, this value exceeds out of the regulation’s range as well as breaking capacity of the protection devices. In this paper, a fault current limiter (FCL) device is introduced as a solution; it works as a high impedance in short circuit cases and low impedance in normally case. This paper simulates the fault current limiter transformer type in MATLAB/SIMULINK, the effect of FCLT’s parameters to short circuit reduction is given in the results. Application of FCLT in reality network also is presented with markable results of short circuit reduction in Ho Chi Minh Power Corporation‘s distribution system.