scholarly journals Microgrid as a Cost-Effective Alternative to Rural Network Underground Cabling for Adequate Reliability

Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 1978 ◽  
Author(s):  
Sanna Uski ◽  
Erkka Rinne ◽  
Janne Sarsama

Microgrids can be used for securing the supply of power during network outages. Underground cabling of distribution networks is another effective but conventional and expensive alternative to enhance the reliability of the power supply. This paper first presents an analysis method for the determination of microgrid power supply adequacy during islanded operation and, second, presents a comparison method for the overall cost calculation of microgrids versus underground cabling. The microgrid power adequacy during a rather long network outage is required in order to indicate high level of reliability of the supply. The overall cost calculation considers the economic benefits and costs incurred, combined for both the distribution network company and the consumer. Whereas the microgrid setup determines the islanded-operation power adequacy and thus the reliability of the supply, the economic feasibility results from the normal operations and services. The methods are illustrated by two typical, and even critical, case studies in rural distribution networks: an electric-heated detached house and a dairy farm. These case studies show that even in the case of a single consumer, a microgrid option could be more economical than network renovation by underground cabling of a branch in order to increase the reliability.

Author(s):  
Sanna Uski ◽  
Erkka Rinne ◽  
Janne Sarsama

Microgrids can be used for securing power supply during network outages. Underground cabling of distribution networks is another effective, but conventional and expensive alternative to enhance reliability of power supply. This paper presents firstly an analysis method for the determination of microgrid power supply adequacy during islanded operation, and secondly, a comparison method for overall cost calculation of microgrids vs. underground cabling. The microgrid power adequacy during a rather long network outage is required in order to indicate high level of reliability of supply. The overall cost calculations consider the economic benefits and costs incurred combined for both the distribution network company and the consumer. Whereas the microgrid setup determines the islanded operation power adequacy and thus the reliability of supply, the economic feasibility results from the normal operations and services. The methods are illustrated by two typical, and even critical, case studies in rural distribution networks: an electric-heated detached house and a dairy farm. These case studies show that even in case of a single consumer, a microgrid option could be more economical than network renovation by underground cabling of a branch in order to increase reliability.


Author(s):  
Laura Soares ◽  
Hao Wang

Many airports are converting their ground fleets to electric vehicles to reduce greenhouse gas emissions and increase airport operation sustainability. Although this paradigm shift is relevant to the environment, it is necessary to understand the economic feasibility to justify the decision. This study used life-cycle cost analysis (LCCA) to compare the economic performance of electrified ground fleets in the airport with a conventional fossil fuel fleet. Three different charging systems (plug-in charging, stationary wireless charging, and dynamic wireless charging) for pushback tractors and inter-terminal buses at a major hub airport were considered in the analysis. Although the conventional fossil fuel options present the lowest initial cost for both fleets, they cost most in a 30-year analysis period. Among three electric charging infrastructures, the plug-in charging station shows the least accumulative cost for pushback tractors, and their cost differences are negligible for inter-terminal buses. Although the electric ground fleet is proved to show economic benefits, the most cost-effective charging infrastructure may vary depending on driving mileage and system design. The use of LCCA to analyze new systems and infrastructures for decision making at the project level is highly recommended.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 728
Author(s):  
Juan Pedrero ◽  
Patxi Hernández ◽  
Álvaro Martínez

This paper presents an analysis of the economic performance of photovoltaic (PV) self-consumption systems at an industrial park in the Basque Country (north of Spain). The economic feasibility of the installations is largely dependent on self-consumption and compensation due to electricity injected into the grid, as well as the assumed evolution of the electricity prices. A sensitivity analysis is carried out for different installation sizes and different evolution scenarios concerning electricity prices. The potential for installations for shared self-consumption with dynamic and static distribution coefficients is also analyzed. The results show that medium sized installations are generally a cost effective way to reduce energy bills, while the economic performance of larger installations is more uncertain, and is largely dependent on the selling price for electricity injected into the grid. This case study found that the economic benefits of shared self-consumption between different companies are substantial, and are slightly more favorable when applying dynamic distribution factors.


2020 ◽  
Vol 2 (1) ◽  
pp. 1
Author(s):  
Gabriella Balacco ◽  
Mario Binetti ◽  
Tommaso Capurso ◽  
Michele Stefanizzi ◽  
Marco Torresi ◽  
...  

This paper expands on the results of the technical and economic feasibility analysis of substituting existing pressure reduction valves (PRVs) with pumps used as turbines (PaTs) in two real Italian water distribution networks (WDN), chosen as case studies, aiming at effective energy recovery. Water demand variability makes complex the selection of the right pump to be used as a turbine in a WDN maximizing its annual electric energy yield. Hence, this study describes an effective approach that permits us to identify the most suitable pumps, starting from the definition of the best efficiency points at which they should operate in reverse mode.


2013 ◽  
Vol 133 (12) ◽  
pp. 961-966
Author(s):  
Hitoshi Hayashiya ◽  
Kazushi Matsuura ◽  
Norio Koguchi ◽  
Hiroshi Yamamoto ◽  
Tetsuo Fujita

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Jianming Guo ◽  
Kaixuan Huang ◽  
Rou Cao ◽  
Junhua Zhang ◽  
Yong Xu

Abstract Background Xylo-oligosaccharide is the spotlight of functional sugar that improves the economic benefits of lignocellulose biorefinery. Acetic acid acidolysis technology provides a promising application for xylo-oligosaccharide commercial production, but it is restricted by the aliphatic (wax-like) compounds, which cover the outer and inner surfaces of plants. Results We removed aliphatic compounds by extraction with two organic solvents. The benzene–ethanol extraction increased the yield of acidolyzed xylo-oligosaccharides of corncob, sugarcane bagasse, wheat straw, and poplar sawdust by 14.79, 21.05, 16.68, and 7.26% while ethanol extraction increased it by 11.88, 17.43, 1.26, and 13.64%, respectively. Conclusion The single ethanol extraction was safer, more environmentally friendly, and more cost-effective than benzene–ethanol solvent. In short, organic solvent extraction provided a promising auxiliary method for the selective acidolysis of herbaceous xylan to xylo-oligosaccharides, while it had minimal impact on woody poplar.


Author(s):  
Xin Shen ◽  
Hongchun Shu ◽  
Min Cao ◽  
Nan Pan ◽  
Junbin Qian

In distribution networks with distributed power supplies, distributed power supplies can also be used as backup power sources to support the grid. If a distribution network contains multiple distributed power sources, the distribution network becomes a complex power grid with multiple power supplies. When a short-circuit fault occurs at a certain point on the power distribution network, the size, direction and duration of the short-circuit current are no longer single due to the existence of distributed power, and will vary with the location and capacity of the distributed power supply system. The change, in turn, affects the current in the grid, resulting in the generation and propagation of additional current. This power grid of power electronics will cause problems such as excessive standard mis-operation, abnormal heating of the converter and component burnout, and communication system failure. It is of great and practical significance to study the influence of distributed power in distributed power distribution networks.


2021 ◽  
Author(s):  
Benjamin Butler ◽  
Justin Roberts ◽  
Matthew Kelsey ◽  
Steffen Van Der Veen

Abstract Multilateral wells have been proven over decades and have developed into a reliable and cost effective approach to mature field rejuvenation and extended commercial viability. This paper will discuss case studies demonstrating a number of techniques used to create infill multilateral wells in existing fields with a high level of reliability and repeatability. Techniques reviewed will cover cutting and pulling production casing to drill and case a new mainbore versus sidetracking and adding laterals to an existing mainbore. Discussion will also cover completion designs that tie new laterals into existing production casing providing significantly greater reservoir contact. Temporary isolation of high water-cut laterals brought into production later in the well's life through bespoke completion designs will also be discussed. Case studies will include discussion of workover operations, isolation methods, and lateral creation systems. Where available, resulting field performance improvements will also be discussed. In Norway, slot recoveries are commonly performed by cutting and pulling the 10-3/4" casing, redrilling a new mainbore, and running new casing. This enables junction placement closer to unswept zones and easier lateral drilling to targets. It does have drawbacks, however, related to the additional time required to pull the subsea xmas tree and challenges associated with pulling casing. In 2019, Norway successfully completed a 10-3/4" retrofit installation, whereas a sidetrack was made from the 10-3/4" and an 8-5/8" expandable liner was run down into the reservoir pay zone where two new laterals were created. The 8-5/8" liner saved time otherwise spent having to drill the section down to the payzone from the laterals. These wells have a TAML Level 5 isolated junction, Autonomous Inflow Control Devices (AICDs) in each lateral, and an intelligent completion interface across the junction, enabling active flow management and monitoring of both branches. In Asia, infill laterals were added to existing wellbores by sidetracking 9-5/8" casing and tying production back to the original mainbore. These dual laterals were completed with intelligent completions to enable lateral flow management and monitoring of both laterals. In Australia, dual laterals were created in a similar fashion; laterals are added to existing wells; however, a novel approach was used to manage water from existing lower mainbore laterals whereby they are shut in at completion and opened later when the new lateral is watered out. The older lateral now produces at lower water cut given the time allowed for water coning in the lateral to relax. Using this practice, production is alternated back and forth between the two laterals. In the Middle East, an older well has been converted from TAML Level 4 to Level 5 in order to prevent detected gas migrating into the mainbore at the junction. This conversion of a cemented junction well has enabled production to resume on this well. The well was converted to incorporate an intelligent completion to enable flow control of each lateral. This paper intends to provide insights into the various mature field re-entry methods for multilateral well construction, and a review of the current technology capabilities and well designs through the review of multiple case histories.


Sign in / Sign up

Export Citation Format

Share Document