scholarly journals Closing the Wearable Gap—Part IV: 3D Motion Capture Cameras Versus Soft Robotic Sensors Comparison of Gait Movement Assessment

Electronics ◽  
2019 ◽  
Vol 8 (12) ◽  
pp. 1382 ◽  
Author(s):  
David Saucier ◽  
Samaneh Davarzani ◽  
Alana Turner ◽  
Tony Luczak ◽  
Phuoc Nguyen ◽  
...  

The purpose of this study was to use 3D motion capture and stretchable soft robotic sensors (SRS) to collect foot-ankle movement on participants performing walking gait cycles on flat and sloped surfaces. The primary aim was to assess differences between 3D motion capture and a new SRS-based wearable solution. Given the complex nature of using a linear solution to accurately quantify the movement of triaxial joints during a dynamic gait movement, 20 participants performing multiple walking trials were measured. The participant gait data was then upscaled (for the SRS), time-aligned (based on right heel strikes), and smoothed using filtering methods. A multivariate linear model was developed to assess goodness-of-fit based on mean absolute error (MAE; 1.54), root mean square error (RMSE; 1.96), and absolute R2 (R2; 0.854). Two and three SRS combinations were evaluated to determine if similar fit scores could be achieved using fewer sensors. Inversion (based on MAE and RMSE) and plantar flexion (based on R2) sensor removal provided second-best fit scores. Given that the scores indicate a high level of fit, with further development, an SRS-based wearable solution has the potential to measure motion during gait- based tasks with the accuracy of a 3D motion capture system.

Author(s):  
Jonathan Kenneth Sinclair ◽  
Lindsay Bottoms

AbstractRecent epidemiological analyses in fencing have shown that injuries and pain linked specifically to fencing training/competition were evident in 92.8% of fencers. Specifically the prevalence of Achilles tendon pathology has increased substantially in recent years, and males have been identified as being at greater risk of Achilles tendon injury compared to their female counterparts. This study aimed to examine gender differences in Achilles tendon loading during the fencing lunge.Achilles tendon load was obtained from eight male and eight female club level epee fencers using a 3D motion capture system and force platform information as they completed simulated lunges. Independent t-tests were performed on the data to determine whether differences existed.The results show that males were associated with significantly greater Achilles tendon loading rates in comparison to females.This suggests that male fencers may be at greater risk from Achilles tendon pathology as a function of fencing training/ competition.


2017 ◽  
Vol 49 (5S) ◽  
pp. 757
Author(s):  
Jessica L. Halle ◽  
Jacob A. Goldsmith ◽  
Cameron Trepeck ◽  
Ryan K. Byrnes ◽  
Daniel M. Cooke ◽  
...  

2012 ◽  
Vol 45 ◽  
pp. S376
Author(s):  
Anke A. Van Campen ◽  
Friedl De Groote ◽  
Ilse Jonkers ◽  
Joris De Schutter

Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7312
Author(s):  
Julia Mazzarella ◽  
Mike McNally ◽  
Daniel Richie ◽  
Ajit M. W. Chaudhari ◽  
John A. Buford ◽  
...  

Perinatal stroke (PS), occurring between 20 weeks of gestation and 28 days of life, is a leading cause of hemiplegic cerebral palsy (HCP). Hallmarks of HCP are motor and sensory impairments on one side of the body—especially the arm and hand contralateral to the stroke (involved side). HCP is diagnosed months or years after the original brain injury. One effective early intervention for this population is constraint-induced movement therapy (CIMT), where the uninvolved arm is constrained by a mitt or cast, and therapeutic activities are performed with the involved arm. In this preliminary investigation, we used 3D motion capture to measure the spatiotemporal characteristics of pre-reaching upper extremity movements and any changes that occurred when constraint was applied in a real-time laboratory simulation. Participants were N = 14 full-term infants: N = six infants with typical development; and N = eight infants with PS (N = three infants with PS were later diagnosed with cerebral palsy (CP)) followed longitudinally from 2 to 6 months of age. We aimed to evaluate the feasibility of using 3D motion capture to identify the differences in the spatiotemporal characteristics of the pre-reaching upper extremity movements between the diagnosis group, involved versus uninvolved side, and with versus and without constraint applied in real time. This would be an excellent application of wearable sensors, allowing some of these measurements to be taken in a clinical or home setting.


Author(s):  
Per-Anders Fransson ◽  
Maria H. Nilsson ◽  
Diederick C. Niehorster ◽  
Marcus Nyström ◽  
Stig Rehncrona ◽  
...  

Abstract Background Tremor is a cardinal symptom of Parkinson’s disease (PD) that may cause severe disability. As such, objective methods to determine the exact characteristics of the tremor may improve the evaluation of therapy. This methodology study aims to validate the utility of two objective technical methods of recording Parkinsonian tremor and evaluate their ability to determine the effects of Deep Brain Stimulation (DBS) of the subthalamic nucleus and of vision. Methods We studied 10 patients with idiopathic PD, who were responsive to L-Dopa and had more than 1 year use of bilateral subthalamic nucleus stimulation. The patients did not have to display visible tremor to be included in the study. Tremor was recorded with two objective methods, a force platform and a 3 dimensional (3D) motion capture system that tracked movements in four key proximal sections of the body (knee, hip, shoulder and head). They were assessed after an overnight withdrawal of anti-PD medications with DBS ON and OFF and with eyes open and closed during unperturbed and perturbed stance with randomized calf vibration, using a randomized test order design. Results Tremor was detected with the Unified Parkinson’s Disease Rating Scale (UPDRS) in 6 of 10 patients but only distally (hands and feet) with DBS OFF. With the force platform and the 3D motion capture system, tremor was detected in 6 of 10 and 7 of 10 patients respectively, mostly in DBS OFF but also with DBS ON in some patients. The 3D motion capture system revealed that more than one body section was usually affected by tremor and that the tremor amplitude was non-uniform, but the frequency almost identical, across sites. DBS reduced tremor amplitude non-uniformly across the body. Visual input mostly reduced tremor amplitude with DBS ON. Conclusions Technical recording methods offer objective and sensitive detection of tremor that provide detailed characteristics such as peak amplitude, frequency and distribution pattern, and thus, provide information that can guide the optimization of treatments. Both methods detected the effects of DBS and visual input but the 3D motion system was more versatile in that it could detail the presence and properties of tremor at individual body sections.


Sign in / Sign up

Export Citation Format

Share Document