scholarly journals Fast Fallback Watermark Detection Using Perceptual Hashes

Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1155
Author(s):  
Hannes Mareen ◽  
Niels Van Kets ◽  
Peter Lambert ◽  
Glenn Van Wallendael

Forensic watermarking is often used to enable the tracing of digital pirates that leak copyright-protected videos. However, existing watermarking methods have a limited robustness and may be vulnerable to targeted attacks. Our previous work proposed a fallback detection method that uses secondary watermarks rather than the primary watermarks embedded by existing methods. However, the previously proposed fallback method is slow and requires access to all watermarked videos. This paper proposes to make the fallback watermark detection method faster using perceptual hashes instead of uncompressed secondary watermark signals. These perceptual hashes can be calculated prior to detection, such that the actual detection process is sped up with a factor of approximately 26,000 to 92,000. In this way, the proposed method tackles the main criticism about practical usability of the slow fallback method. The fast detection comes at the cost of a modest decrease in robustness, although the fast fallback detection method can still outperform the existing primary watermark method. In conclusion, the proposed method enables fast and more robust detection of watermarks that were embedded by existing watermarking methods.

2015 ◽  
Vol 671 ◽  
pp. 356-362 ◽  
Author(s):  
Zhi Feng Chen ◽  
Yuan Quan Hong ◽  
Chang Jiang Wan ◽  
Lian Ying Zhao

A fast non-destructive method of detection of wool content in blended fabrics was studied based on Near Infrared spectroscopy technology in order to avoid the time-consuming, tedious work and the destruction of samples in the traditional inspection. 621 wool/nylon, wool/polyester and wool/nylon/polyester blended fabrics were taken as research objects. To get the wool content, we established the wool near-infrared quantitative model by partial least squares (PLS) method after analyzing the color and composition of the samples. For verifying the validity and practicability of the model, 100 samples were chosen as an independent validation set. The variance analysis shows that there is no significant difference between Near Infrared fast detection method and national standard method (GB/T2910-2009),which indicates that this method is expected to be a means of fast non-destructive detection and will have extensive application future in the field of wool content detection.


1990 ◽  
Vol 112 (2) ◽  
pp. 276-282 ◽  
Author(s):  
S. Tanaka ◽  
P. C. Mu¨ller

The detection of an abrupt change in the parameters of a linear discrete dynamical system is considered in the framework of the easily implemented generalized-likelihood-ratio (GLR) method. This paper proposes a robust detection method based on a pattern recognition of the maximum GLR provided by the conventional step-hypothesized GLR method. A numerical example demonstrates that the proposed method is highly superior to the conventional step-hypothesized GLR method and to the Chi-squared test in both detection rate and detection speed.


This paper describes the cross-language plagiarism detection method CLAD (Cross-Language Analog Detector) between test document and indexed documents. The main difference of this method from existing versions is the detection of plagiarism among multiple languages not only two languages. While translating terms, it used the dictionary-based machine-translation method. CLAD’s working process consists of document indexing and detection process phases. In this paper, we will describe both of these phases.


Author(s):  
Megh Singh Dhakad ◽  
Sanjib Gogoi ◽  
Ansu Kumari ◽  
Aashish Kumar Singh ◽  
Manoj B. Jais ◽  
...  

Background and Objectives: The entire globe is undergoing an unprecedented challenge of COVID-19. Considering the need of rapid and accurate diagnostic tests for SARS-CoV-2, this study was planned to evaluate the cost effective extraction free RT-PCR technique in comparison to the standard VTM based RT-qPCR method. Materials and Methods: Paired swabs from nasopharynx and oropharynx were collected for SARS-CoV-2 testing, from 211 adult patients (≥18 years) in VTM and plain sterile tubes (dry swabs). These samples were processed and RT-qPCR was carried out as per standard protocols. Results: 54.5% of the patients were females and 45.5% were males with sex ratio 1:1.19 (M: F). 38.86% were symptomatic, of which fever (86.59%), cough (79.23%) and breathlessness (46.34%) were the most common symptoms. The positivity by VTM based method and index method was 31.27% and 13.27% respectively. Of the 27 inconclusive results from index method, 37.04% were positive, 48.15% were negative by VTM based method. However, in 40 inconclusive results by VTM based method, 90% were negative and rest remained inconclusive by index method. The sensitivity and specificity of the index method were 39.39% and 85.71% respectively. The overall agreement between VTM based method and index method was 49.59% with estimated Kappa value of 0.19. Conclusion: VTM based method showed higher sensitivity compared to the index method. The higher positivity by VTM based method, suggests that VTM based method could plausibly be a better detection method of SARS-CoV-2. Still, the index method might add value in a resource limited setups for detection of SARS-CoV-2.  


Author(s):  
Jing Hu ◽  
Wei Zhao ◽  
Yanwu Xu ◽  
Jia Dongya ◽  
Cong Yan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document