scholarly journals Design and Analysis of the IGBT Heat Dissipation Structure Based on Computational Continuum Mechanics

Entropy ◽  
2020 ◽  
Vol 22 (8) ◽  
pp. 816
Author(s):  
Xin Lin ◽  
Huawei Wu ◽  
Zhen Liu ◽  
Baosheng Ying ◽  
Congjin Ye ◽  
...  

With the trend of high integration and high power of insulated gate bipolar transistor (IGBT) components, strict requirements have been placed on the heat dissipation capabilities of the IGBT devices. On the basis of traditional rectangular fins, this paper developed two new types of heat-dissipating fins to meet the high requirements of heat dissipation for the IGBT devices. One is the rectangular radiator with a groove length of 2.5 mm and a width of 0.85 mm, the other is the arc radiator with the angle of 125 arc angle, 0.8 mm arc height, and 1.4 mm circle radius. After theoretically calculating the IGBT junction temperature, numerical simulations have been implemented to verify the theoretical result. The commercial CFD software, STAR-CCM+, was employed to simulate the heat dissipation characteristics of the IGBT module under different wind speeds, power, and fin structures. By analyzing the temperature field and vector field of the IGBT module, the analysis results demonstrate that the error between the simulation result and the theoretical calculation is within 5%, which proves the feasibility of the newly designed heat-dissipating fins. When the wind speed is 12.5 m/s, the power is 110 W, the fin height is 31.2 mm, and the fin thickness is 2.3 mm, the rectangular radiator can achieve the best heat dissipation performance.

Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3962 ◽  
Author(s):  
Zilang Hu ◽  
Xinglai Ge ◽  
Dong Xie ◽  
Yichi Zhang ◽  
Bo Yao ◽  
...  

The aging fracture of bonding wire is one of the main reasons for failure of insulated gate bipolar transistor (IGBT). This paper proposes an online monitoring method for IGBT bonding wire aging that does not interfere with the normal operation of the IGBT module. A quantitative analysis of aging degree was first performed, and the results of multivariate and univariate monitoring were compared. Based on the relationship between the monitoring parameters and the aging of the IGBT bonding wire, gradual damage of the IGBT bond wire was implemented to simulate aging failure and obtain the aging data. Moreover, the change of junction temperature was considered to regulate monitoring parameters. Then, the aging degree was evaluated by an artificial neural network (ANN) algorithm. The experimental results showed the effectiveness of the proposed method.


Electronics ◽  
2019 ◽  
Vol 8 (10) ◽  
pp. 1066 ◽  
Author(s):  
Zhen Hu ◽  
Wenfeng Zhang ◽  
Juai Wu

Junction temperature is a key parameter that influences both the performance and the reliability of the insulated gate bipolar transistor (IGBT) module, while solder fatigue has a significant effect on the accuracy of junction temperature estimates using the electro-thermal model. In this paper, an improved electro-thermal model, which is independent of solder fatigue, is proposed to accurately estimate the junction temperature of IGBT module. Firstly, solder fatigue conditions are monitored in real time with the information of the case temperatures. Secondly, when solder fatigue is found, the update process of the electro-thermal model parameters is performed to match the model parameters with the fatigue device. With the above two-step process, the influence of solder fatigue on the accuracy of temperature estimates can be removed in good time. Experimental results are provided to validate the effectiveness of the proposed method.


2013 ◽  
Vol 732-733 ◽  
pp. 161-164 ◽  
Author(s):  
Ai Chun Ma ◽  
Ya Hui Wang ◽  
Jian Ping Ou ◽  
Cheng Jian Zhou

Based on the forward voltage measurement principle, a test device was designed for junction temperature measurement. The voltage temperature coefficient is-1.49mV/°C according to the experimental data, and a series of junction temperatures were obtained on various ambient temperature. A numerical model was built by using the CFD software Flent, which was verified with the experimental data. The influence of the different structure parameters of the heat sink on heat dissipation performance was studied numerically. The results show that the optimal structure parameters were as following: Fin number is within 8~12. Fin height is within 170mm~190mm. Fin length is within 35mm~55mm. Fin thickness is within 1mm~3mm. Bases radius is within 33mm~40mm. With the chip junction temperature and the radiator weight as optimizing object, the optimal parameters were obtained as following: Fin number is 12. Fin height is 190mm. Fin length is 55mm. Fin thickness is 1.5mm. Bases radius is 33 mm.


Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1791 ◽  
Author(s):  
Qingyi Kong ◽  
Mingxing Du ◽  
Ziwei Ouyang ◽  
Kexin Wei ◽  
William Gerard Hurley

On-state voltage is an important thermal parameter for insulated gate bipolar transistor (IGBT) modules. It is employed widely to predict failure in IGBT module bond wires. However, due to restrictions in work environments and measurement methods, it is difficult to ensure the measurement accuracy for the on-state voltage under practical working conditions. To address this problem, an on-state voltage separation strategy is proposed for the IGBT modules with respect to the influence of collector current (Ic) and junction temperature (Tj). This method involves the separation of the on-state voltage into a dependent part and two independent parts during the IGBT module bond wire prediction. Based on the proposed separation strategy, the independent parts in the failure prediction can be removed, making it possible to directly monitor the voltage variations caused by bond wire failure. The experimental results demonstrate that the proposed diagnosis strategy can accurately predict the bond wire failure stage in an IGBT module under different conditions.


Electronics ◽  
2021 ◽  
Vol 10 (12) ◽  
pp. 1449
Author(s):  
Chuankun Wang ◽  
Yigang He ◽  
Yunfeng Jiang ◽  
Lie Li

Due to the constant changes of the environment and load, the insulated-gate bipolar transistor (IGBT) module is subjected to a large amount of junction temperature (Tj) fluctuations, which often leads to damage to the bond wires. The monitoring parameters of IGBTs are often coupled with Tj, which increases the difficulty of monitoring IGBTs’ health status online. In this paper, based on the collector current (Ic) and collector-emitter on-state voltage (Vce_on) online monitoring circuit, an online monitoring method of IGBT bond wire aging against interference is proposed. First, the bond wire aging model is established, and the Vce_on is selected as the monitoring parameter. Secondly, taking a three-phase inverter circuit as an example, the Vce_on and Ic waveforms of the IGBT module are monitored in real time, and the process of online monitoring is introduced accordingly. Finally, the experimental results indicate that the method proposed in this paper can accurately identify the aging state of IGBT bond wires under different conditions.


Author(s):  
Améni Driss ◽  
Samah Maalej ◽  
Mohamed Chaker Zaghdoudi

This paper deals with the development of an electro-thermal model of an Insulated Gate Bipolar Transistor (IGBT) with a water-cooled heat pipe cooling system. Firstly, a thermal model of the heat pipe cooling system is proposed. Then, an electro-thermal model of the IGBT is developed to predict the junction temperature variations in transient operation. The thermal model of the IGBT is determined on the base of the thermal-capacitance lumped method. The electrical model of the IGBT is developed by considering the effect of the junction temperature on its static electrical parameters. Finally, the electro-thermal model is considered in a boost converter application. The model predictions show the effectiveness of the heat pipe cooling system for different commutation frequencies. It is proved that the heat pipe cooling system can keep the junction temperature of the IGBT at values allowing safe operation.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1364
Author(s):  
Guishan Yan ◽  
Zhenlin Jin ◽  
Mingkun Yang ◽  
Bing Yao

The electro-hydraulic servo pump control system (EHSPCS) is a high-performance control unit that integrates a permanent magnet synchronous motor (PMSM) and a closed hydraulic system (CHS). The design features of high integration and a high power-weight ratio lead to the poor heat dissipation capacity and high thermal balance temperature of the system. Excessive temperature will seriously affect the system’s performance and service life. Therefore, the thermal balance analysis method of the EHSPCS under different loads and different wind speeds was proposed in this paper. Firstly, the PMSM and CHS were taken as research objects to analyze the heating source of the system. The thermal power model was established, and the calculation was performed. The variation rule of the thermal power generated by each component with the load torque under the typical rotating speed was obtained. Secondly, the system’s temperature field thermal balance solution model was established. ANSYS and AMESim software were used to calculate the thermal balance points of the PMSM and CHS under different working conditions. The change rule of the thermal balance temperature field of the EHSPCS under different loads was analyzed with the conditions of the natural cooling and forced wind cooling of the PMSM. Finally, an experimental platform was built for experimental research, and the experimental temperature of the system under different loads and different wind speeds was measured. Through comparison and analysis with the simulation results, the correctness and feasibility of the thermal balance theoretical analysis method were verified. The research results will lay the foundation for thermal balance research on the EHSPCS, and have guiding significance for system design, component selection, and load matching.


Electronics ◽  
2020 ◽  
Vol 9 (8) ◽  
pp. 1294 ◽  
Author(s):  
Chuankun Wang ◽  
Yigang He ◽  
Chenyuan Wang ◽  
Xiaoxin Wu ◽  
Lie Li

Due to the diversity of distributed generation sources, microgrid inverters work under complex and changeable conditions. The core device of inverters, an insulated gate bipolar transistor (IGBT), bears a large amount of thermal stress impact, so its reliability is related to the stable operation of the microgrid. The effect of the IGBT aging process cannot be considered adequately with the existing reliability evaluation methods, which have not yet reached the requirements of online evaluation. This paper proposes a fusion algorithm for online reliability evaluation of microgrid inverter IGBT, which combines condition monitoring and reliability evaluation. Firstly, based on the microgrid inverter topology and IGBT characteristics, an electrothermal coupling model is established to obtain junction temperature data. Secondly, the segmented long short-term memory (LSTM) algorithm is studied, which can accurately predict the aging process of the IGBT and judge the aging state via the limited monitoring data. Then, the parameters of the electrothermal coupling model are corrected according to the aging process. Besides, the fusion algorithm is applied to the practical case. Finally, the data comparison verifies the feasibility of the fusion algorithm, whose cumulative damage degree and estimated life error are 5.10% and 5.83%, respectively.


Machines ◽  
2021 ◽  
Vol 9 (1) ◽  
pp. 17
Author(s):  
Chen Yang ◽  
Long-jie Yu ◽  
Junhui Zhang ◽  
Jin-yuan Qian

Realizing conversion between fluid power and mechanical energy, the closed circuit axial piston transmission (CCAPT) plays a vital and indispensable role in miscellaneous industries. The frictional loss and leakage loss inside the system give rise to the inevitable temperature rise. In order to prolong the life of the device, a cooling structure on the outside of the CCAPT is designed for promoting heat dissipation. Based on the relevant heat transfer law and the temperature distribution of internal machinery elements, a spiral fin structure is designed at the shell side. With the help of numerical simulation, the effects of fin height, fin pitch, and fin thickness on the thermal performance are studied. The flow field and temperature field on the outside of the fin structure are obtained as a guidance for enhancing heat dissipation effect. Results indicate that the area of rotating elements tend to accumulate heat, where more attention should be paid for a better cooling effect. In addition to this, a moderate increase of fin height, fin pitch and fin thickness has a positive effect on heat transfer enhancement. The peak value of Nusselt number is obtained with a fin height of 7.5 mm, which is about 2.09 times that of the condition without the fin structure. An increase in fin pitch improves both heat transfer performance and comprehensive performance at the same. When fin pitch is 30 mm, Nusselt numberincreases 104% over the original condition.


Sign in / Sign up

Export Citation Format

Share Document