scholarly journals Numerical Study of Nanofluid Irreversibilities in a Heat Exchanger Used with an Aqueous Medium

Entropy ◽  
2020 ◽  
Vol 22 (1) ◽  
pp. 86
Author(s):  
Guillermo Efren Ovando-Chacon ◽  
Sandy Luz Ovando-Chacon ◽  
Abelardo Rodriguez-Leon ◽  
Mario Diaz-Gonzalez ◽  
Jorge Arturo Hernandez-Zarate ◽  
...  

Heat exchangers play an important role in different industrial processes; therefore, it is important to characterize these devices to improve their efficiency by guaranteeing the efficient use of energy. In this study, we carry out a numerical analysis of flow dynamics, heat transfer, and entropy generation inside a heat exchanger; an aqueous medium used for oil extraction flows through the exchanger. Hot water flows on the shell side; nanoparticles have been added to the water in order to improve heat transfer toward the cold aqueous medium flowing on the tube side. The aqueous medium must reach a certain temperature in order to obtain its oil extraction properties. The analysis is performed for different Richardson numbers (Ri = 0.1–10), nanofluid volume fractions (φ = 0.00–0.06), and heat exchanger heights (H = 0.6–1.0). Results are presented in terms of Nusselt number, total entropy generation, Bejan number, and performance evaluation criterion. Results showed that heat exchanger performance increases with the increase in Ri when Ri > 1 and when reducing H.

2015 ◽  
Vol 55 (4) ◽  
pp. 267 ◽  
Author(s):  
Jan Skočilas ◽  
Ievgen Palaziuk

<p>This paper deals with a computational fluid dynamics (CFD) simulation of the heat transfer process during turbulent hot water flow between two chevron plates in a plate heat exchanger. A three-dimensional model with the simplified geometry of two cross-corrugated channels provided by chevron plates, taking into account the inlet and outlet ports, has been designed for the numerical study. The numerical model was based on the shear-stress transport (SST) <em>k-!</em> model. The basic characteristics of the heat exchanger, as values of heat transfer coefficient and pressure drop, have been investigated. A comparative analysis of analytical calculation results, based on experimental data obtained from literature, and of the results obtained by numerical simulation, has been carried out. The coefficients and the exponents in the design equations for the considered plates have been arranged by using simulation results. The influence on the main flow parameters of the corrugation inclination angle relative to the flow direction has been taken into account. An analysis of the temperature distribution across the plates has been carried out, and it has shown the presence of zones with higher heat losses and low fluid flow intensity.</p>


2021 ◽  
Vol 39 (5) ◽  
pp. 1583-1589
Author(s):  
Ali K. Abdul Razzaq ◽  
Khudheyer S. Mushatet

The thermal and fluid physiognomies of a double twisted tube heat exchanger was examined numerically. Twisted engineering is a wide-use method to improve heat transfer in heat exchangers. A counter-flow mode utilizing hot water in the inner tube and cold air in the outer tube was considered. This study aims to progress the thermal performance of the double tube heat exchanger by using twisted tubes instead of plane tubes. The heat exchanger was (1m) length, outer diameter (0.05m) and inner diameter (0.025m), both with a thickness (0.004m). It was tested for different values of twist ratios (Tr= 5, 10, and 15 respectively) and Reynolds numbers (Re=5000 to 30000). The Navier - Stockes and energy equations besides the turbulence model in demand for modelling this physical problem. ANSYS Fluent code was used for the numerical simulation. The results showed that the twisted tube heat exchanger showed increasing heat transfer compared with a plain tube heat exchanger. It was found that the cold outlet temperature, pressure drop and effectiveness are increased as the twist ratio increases.


2015 ◽  
Vol 138 (1) ◽  
Author(s):  
R. K. Nayak ◽  
S. Bhattacharyya ◽  
I. Pop

A numerical investigation of mixed convection due to a copper–water nanofluid in an enclosure is presented. The mixed convection is governed by moving the upper lid of the enclosure and imposing a vertical temperature gradient. The transport equations for fluid and heat are modeled by using the Boussinesq approximation. A modified form of the control volume based SIMPLET algorithm is used for the solution of the transport equations. The fluid flow and heat transfer characteristics are studied for a wide range of Reynolds number and Grashof number so as to have the Richardson number greater or less than 1. The nanoparticle volume fraction is considered up to 20%. Heat flow patterns are analyzed through the energy flux vector. The rate of enhancement in heat transfer due to the addition of nanoparticles is analyzed. The entropy generation and Bejan number are evaluated to demonstrate the thermodynamic optimization of the mixed convection. We have obtained the enhancement rate in heat transfer and entropy generation in nanofluid for a wide range of parameter values.


2021 ◽  
Vol 2021 ◽  
pp. 1-28
Author(s):  
Amnart Boonloi ◽  
Withada Jedsadaratanachai

The impacts of the double V-rings (DVR) in the heat exchanger duct (HED) on heat transfer and flow structures are numerically analyzed. The general configuration of the DVR is called “type I,” while the discrete DVR can be split into two structures, which are called “types II and III.” The influences of the DVR sizes, DVR types and flow directions on heat transfer rate, friction loss, and thermohydraulic performance are considered. The Reynolds numbers in the range around 100–2000 (laminar regime at the entrance condition) are selected for the present investigation. The numerical problem of the HED installed with the DVR is solved with the finite volume method (a commercial code). The flow structure, heat transfer mechanism, and performance analysis in the HED that fitted the DVR are reported. The flow and heat transfer profiles in the HED fitted with the DVR are an important knowledge to develop the thermohydraulic performance of compact heat exchangers. As the numerical results, it is seen that the heat transfer ability of the tested duct improves around 1.05–16.62 times upper than the smooth duct. Additionally, the greatest value of the thermal enhancement factor in the HED fitted with the DVR is seen to be around 4.17 at a/H = 0.025, b/H = 0.10, Re = 2000, and V-upstream direction for the type I.


2019 ◽  
Vol 142 (1) ◽  
Author(s):  
S. Dutta ◽  
S. Bhattacharyya ◽  
I. Pop

Abstract A numerical study on the mixed convection of Al2O3–water nanofluid in a lid-driven inclined square enclosure partially heated from below is performed based on Buongiorno's two phase model. The velocity of the nanoparticles relative to the base fluid is considered due to thermophoresis and Brownian diffusion. The thermophysical properties of the nanofluid are assumed to be dependent on temperature as well as the nanoparticle volume fraction. A control volume method over a staggered grid arrangement is used to discretize the governing equations. The discretized equations of two-dimensional continuity, momentum, energy, and volume fraction are solved through a pressure-correction-based semi-implicit method for pressure linked equations (SIMPLE) algorithm. The effects of relevant parameters such as nanoparticle diameter (25 nm ≤ dp ≤ 90 nm), Richardson number (0.1≤Ri≤5), nanoparticle bulk volume fraction (0 ≤φb≤ 0.05) on the mixed convection of the nanofluid is studied by considering the inclination angle of the enclosure to vary between 0 deg and 60 deg. The entropy generation as well as the Bejan number is evaluated to illustrate the thermodynamic optimization of the mixed convection. Both the heat transfer and entropy generation are higher in the nanofluid compared to the clear fluid and the rate of increment in entropy generation remains lower than the rate by which the heat transfer is augmented in the nanofluid. We find that due to the presence of the Brownian diffusion and thermophoresis in the nonhomogeneous model, a higher heat transfer is yielded as compared to the homogeneous model. The discrepancy between the homogeneous and nonhomogeneous models is significant when the mixed convection is dominated by the shear force. When the mixed convection is dominated by the thermal buoyancy, an increase in positive inclination angle of the enclosure creates a significant increment in the heat transfer.


2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


Sign in / Sign up

Export Citation Format

Share Document