scholarly journals Implant Diameter, Length, and the Insertion Torque/Depth Integral: A Study Using Polyurethane Foam Blocks

2020 ◽  
Vol 8 (2) ◽  
pp. 56
Author(s):  
Paolo Arosio ◽  
Federico Arosio ◽  
Danilo Alessio Di Stefano

The amount of energy necessary to place an implant in its seat, described as the integral of the torque-depth curve at insertion (I), has been validated as a reliable measure of primary stability. This study aimed to investigate whether (I) may detect the variations in primary stability caused by changes in the implant length or diameter better than the insertion torque (IT). Cylindric implants featuring a double-etched, sandblasted surface with different diameters or lengths were placed into monolithic polyurethane foam blocks with different densities that mimicked human bone. (I)-, (I)*-, IT-, IT*-diameter and -length plots ((I)* and IT* were the derived values corrected for undersizing) were drawn and the relation between (I), (I)*, IT, and IT* and the fixture diameter or length was investigated with correlation analysis. (I)* and IT* correlated better than (I) and IT with the fixture diameter; (I), (I)*, IT, and IT* correlated equally well with the fixture length. In all cases, the slopes of the lines best fitting the experimental data were greater for (I) or (I)* than IT or IT*, respectively. (I) or (I)* were better detectors than IT or IT* of the changes in primary stability that can be achieved by increasing the fixture diameter or length.

2020 ◽  
Vol 46 (3) ◽  
pp. 182-189 ◽  
Author(s):  
Davide Farronato ◽  
Mattia Manfredini ◽  
Michele Stocchero ◽  
Mattia Caccia ◽  
Lorenzo Azzi ◽  
...  

The aim of this study was to evaluate the influence of bone quality, drilling technique, implant diameter, and implant length on insertion torque (IT) and resonance frequency analysis (RFA) of a prototype-tapered implant with knife-edge threads. The investigators hypothesized that IT would be affected by variations in bone quality and drilling protocol, whereas RFA would be less influenced by such variables. The investigators implemented an in vitro experiment in which a prototype implant was inserted with different testing conditions into rigid polyurethane foam blocks. The independent variables were: bone quality, drilling protocol, implant diameter, and implant length. Group A implants were inserted with a conventional drilling protocol, whereas Group B implants were inserted with an undersized drilling protocol. Values of IT and RFA were measured at implant installation. IT and RFA values were significantly correlated (Pearson correlation coefficient: 0.54). A multivariable analysis showed a strong model. Higher IT values were associated with drilling protocol B vs A (mean difference: 71.7 Ncm), implant length (3.6 Ncm increase per mm in length), and substrate density (0.199 Ncm increase per mg/cm3 in density). Higher RFA values were associated with drilling protocol B vs A (mean difference: 3.9), implant length (1.0 increase per mm in length), and substrate density (0.032 increase per mg/cm3 in density). Implant diameter was not associated with RFA or IT. Within the limitations of an in vitro study, the results of this study suggest that the studied implant can achieve good level of primary stability in terms of IT and RFA. A strong correlation was found between values of IT and RFA. Both parameters are influenced by the drilling protocol, implant length, and substrate density. Further studies are required to investigate the clinical response in primary stability and marginal bone response.


Osteology ◽  
2021 ◽  
Vol 1 (1) ◽  
pp. 62-72
Author(s):  
Margherita Tumedei ◽  
Morena Petrini ◽  
Alessandro Cipollina ◽  
Mariastella Di Carmine ◽  
Adriano Piattelli ◽  
...  

Background: Implant primary stability is determined by screw characteristics and surgical procedure. The aim of the present study was to evaluate, on a polyurethane model, the insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA) of multi-scale roughness dental implants of different diameters. Methods: Two implant sizes were tested on two polyurethane blocks (20 pounds per cubic foot (PCF) and 30 PCF): 3.0 diameter and 13 mm length and 5.0 diameter and 13 mm length. The IT, RT, and RFA were assessed. Results: A significant difference of IT and RT was present in favor of wider implants at both polyurethane densities. No statistical difference was present between the 5.0 diameter and 3.0 diameter implants at both polyurethane densities. A statistically increased RFA was reported for 5.0 implant 30 PCF polyurethane blocks. Conclusions: Multi-scale roughness dental implants of both diameters showed high insertion torque and primary stability on polyurethane blocks, which is valuable for implant loading protocols.


2019 ◽  
Vol 7 (1) ◽  
pp. 25 ◽  
Author(s):  
Danilo Di Stefano ◽  
Paolo Arosio ◽  
Vittoria Perrotti ◽  
Giovanna Iezzi ◽  
Antonio Scarano ◽  
...  

During insertion of dental implants, measurement of dynamic parameters such as the torque-depth curve integral or insertion energy might convey more information about primary stability than traditional static parameters such as the insertion or removal torque. However, the relationship between these dynamic parameters, bone density, and implant geometry is not well understood. The aim of this investigation was to compare static and dynamic implant stability measurements concerning three different implant designs when implants were inserted into bovine bone ribs and dynamic parameters were collected using an instantaneous torque measuring implant motor. Standard implant osteotomies were created in segments of bovine ribs. After measuring the bone density using the implant motor, 10 cylindrical, 10 hybrid tapered-cylindrical, and 10 modified cylindrical implants were placed, and their primary stability was assessed by measuring the torque–depth curve integral, along with insertion and removal torque. The relationship between these quantities, bone density, and implant geometry was investigated by means of regression and covariance analysis. The regression lines describing the relationship between the torque–depth integral and bone density differed significantly from those describing the relationship between insertion torque, removal torque, and bone density for all three designs. The torque–depth curve integral provides different information about immediate primary stability than insertion and removal torque and in certain clinical conditions might be more reliable than these static parameters for assessing implant primary stability. Further research should be carried out to investigate the findings of the present study.


TAPPI Journal ◽  
2013 ◽  
Vol 12 (3) ◽  
pp. 9-14
Author(s):  
RENMEI XU ◽  
CELESTE M. CALKINS

This work investigates the ink mileage of dry toners in electrophotography (EP). Four different substrates were printed on a dry-toner color production Xerox iGen3 EP press. The print layout contained patches with different cyan, magenta, yellow, and black tonal values from 10% to 100%. Toner amounts on cyan patches were measured using an analytical method. Printed patches and unprinted paper samples, as well as dry toners, were dissolved in concentrated nitric acid. The copper concentrations in the dissolved solutions were analyzed by a Zeeman graphite furnace atomic absorption spectrometer. Analytical results were calculated to determine the toner amounts on paper for different tonal values. Their corresponding reflection densities were also measured. All data were plotted with OriginPro® 8 software, and four mathematical models were used for curve fitting. It was found that the C-S model fitted the experimental data of the two uncoated papers better than the other three models. None of the four models fitted the experimental data of the two coated papers, while the linear model was found to fit the data well. Linear fitting was the best in the practical density region for the two coated papers. Ink mileage curves obtained from curve fitting were used to estimate how much ink was required to achieve a target density for each paper; hence, the ink mileage was calculated. The highest ink mileage was 3.39 times the lowest ink mileage. The rougher the paper surface, the higher the requirement for ink film weight, and the lower ink mileage. No correlation was found between ink mileage and paper porosity.


Author(s):  
Yaniv Mayer ◽  
Ofir Ginesin ◽  
Hadar Zigdon-Giladi

Implant primary stability, which depends mainly on the amount and quality of bone, is important for implant survival. Socket preservation aims to reduce bone volumetric changes following tooth extraction. This animal study aims to examine whether preserving a ridge by using xenograft impairs the primary stability of the implant. Eighteen artificial bone defects were prepared in four sheep (5mmØ and 8mm length).  Defects were randomly grafted with xenografts: Bio-Oss (BO), Bioactive Bone (BB), or left for natural healing (control). After 8 weeks, bone biopsy was harvested and dental implants installed. During installation, peak insertion torque (IT) was measured by hand ratchet, and primary stability by the Osstell method. Histomorphometric analysis showed a higher percentage of new bone formation in the naturally healed defects compared to sites with xenograft (control 68.66 ± 4.5%, BB 48.75 ± 4.34%, BO 50.33 ± 4.0%). Connective tissue portion was higher in the BO and BB groups compared to control (44.25 ± 2.98%, 41 ± 6%, and 31.33 ± 4.5, p<0.05, respectively). Residual grafting material was similar in BO and BB (7 ± 2.44%, 8.66 ± 2.1 %, respectively). Mean IT and ISQ values were not statistically different among the groups. A positive correlation was found between IT and ISQ (r=0.65, p=0.00). In conclusion, previously grafted defects with xenograft did not influence primary stability and implant insertion torque in delayed implant placement. These results may be attributed to a relatively high bone fill of the defect (~50%) two months after grafting.


2021 ◽  
Vol 11 (12) ◽  
pp. 5612
Author(s):  
Stefano Fanali ◽  
Margherita Tumedei ◽  
Pamela Pignatelli ◽  
Alessandra Lucchese ◽  
Francesco Inchingolo ◽  
...  

Background: Implant primary stability can be affected by several factors related to implant macrogeometry, local anatomy, and surgical techniques. The aim of this research was to study primary stability on polyurethane foam sheets of wide-threaded implant design compared to narrow-threaded implants. Materials and methods: Two different implant designs were positioned on D3 density polyurethane blocks in a standardized environment: the wide-threaded implant and the narrow-threaded implant, for a total of 160 specimens. Moreover, for each group, two different sizes were considered: 3.8mm × 12mm and 4.8mm × 12 mm. The insertion torque (IT) values, the removal strength (RT), and the Periotest analyses were evaluated. Results: A significantly higher IT and RT was reported for wide-threaded implants and two-stage implants (p < 0.01), compared to the narrow-threaded implants. The diameters seemed to provide a significant effect on the primary stability for both implants’ geometry (p < 0.01). A higher mean of the one-stage implant was evident in the Periotest measurements (p < 0.01). Conclusions: Both of the implants showed sufficient stability in polyurethane artificial simulation, while the wide-threaded implant design showed a higher primary stability on alveolar cancellous synthetic bone in vitro. Additionally, the prosthetic joint connection seemed to have a determinant effect on Periotest analysis, and the one-stage implants seemed to provide a high stability of the fixture when positioned in the osteotomy, which could be important for the immediate loading protocol.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 270
Author(s):  
Ji-Hyun Kim ◽  
Young-Jun Lim ◽  
Bongju Kim ◽  
Jungwon Lee

The aim of the present study was to evaluate correlations between bone density and implant primary stability, considering various determinants such as age, gender, and geometry of implants (design, diameter). Bone density of edentulous posterior maxillae was assessed by computed tomography (CT)-derived Hounsfield units, and implant primary stability values were measured with insertion torque and resonance frequency analysis (RFA). A total of 60 implants in 30 partially edentulous patients were evaluated in the posterior maxilla with two different types of dental implants. The bone density evaluated by CT-derived Hounsfield units showed a significant correlation with primary stability parameters. The bone quality was more influenced by gender rather than age, and the type of implant was insignificant when determining primary stability. Such results imply that primary stability parameters can be used for objective assessment of bone quality, allowing surgical modifications especially in sites suspected of poor bone quality.


1997 ◽  
Vol 119 (1) ◽  
pp. 20-25 ◽  
Author(s):  
H. Yuan ◽  
C. Sarica ◽  
S. Miska ◽  
J. P. Brill

A new test facility was designed and constructed to simulate flow in a horizontal well with a single perforation. A total of 635 tests were conducted with Reynolds numbers ranging from 5000 to 60,000 with influx to main rate ratios ranging from 1/5 to 1/100, and also for the no-influx case. The flow behavior in a single-perforation new friction expression for a single-perforation horizontal well was developed. A new simple correlation for the horizontal well friction factor was developed by applying experimental data to the general friction factor expression. The new friction factor correlation and experimental data were compared with the Asheim et al. (1992) data and model, and showed that the new correlation performed better than the Asheim et al. (1992) model.


Sign in / Sign up

Export Citation Format

Share Document