scholarly journals Effectiveness of Ball Attachment Systems in Implant Retained- and Supported-Overdentures: A Three- to Five-Year Retrospective Examination

2019 ◽  
Vol 7 (3) ◽  
pp. 84
Author(s):  
Luca Ortensi ◽  
Matteo Martinolli ◽  
Carlo Borromeo ◽  
Francesco Mattia Ceruso ◽  
Marco Gargari ◽  
...  

Purpose: To evaluate implant and prosthetic survival rates, complications, patient satisfaction, and biological outcomes of patients rehabilitated with a ball attachment system for implant retained- and supported-overdentures (IOV), which was in function for 3 to 5 years. Methods: This retrospective study evaluated data collected from patients treated between April 2001 and May 2018 with IOV on splinted and non-splinted implants and a ball attachment system. Patients were followed for 36 to 206 months (mean follow-up was 128.1 ± 51.9 months). Data were collected at the 3- and 5-year follow-up examination. Outcome measures were implant and prosthetic survival rates, technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), and periodontal parameters (bleeding on probing and plaque index). Results: A total of 46 patients (16 males and 30 females) with 124 implants were included in this study. Twenty-five implant-retained overdentures were delivered on 53 unsplinted implants, while the other 21 patients received an implant-supported overdentures and the implants were splinted. At the five-year follow-up examination, one implant and one prosthesis failed in the unsplinted group, resulting in a cumulative survival rate of 97.8% at the patient level. Two minor technical complications were experienced. Conclusions: Implant overdenture retained or supported by ball attachment systems showed high implant and prosthetic survival and success rates. A low number of complications, high patient satisfaction, and successful biological parameters were experienced in the mid-term follow-up. Data need to be confirmed by further randomized trials.

2018 ◽  
Vol 6 (4) ◽  
pp. 71 ◽  
Author(s):  
Marco Tallarico ◽  
Luca Ortensi ◽  
Matteo Martinolli ◽  
Alessio Casucci ◽  
Emiliano Ferrari ◽  
...  

Purpose: To analyze implant and prosthetic survival rates, complications, patient satisfaction, and biological parameters of patients rehabilitated with implant overdentures (IOV) on splinted and nonsplinted implants and different attachment systems, in function for one to 17 years. Methods: This retrospective study evaluated data collected from patients rehabilitated with implant overdentures between January 2001 and December 2016 in nine different centers. Outcome measures were implant and prosthetic success rates, mechanical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. Results: A total of 581 implants were installed in 194 patients. Patients were followed for a mean period of 60.6 months (range 6–206). Eighty-nine patients received 296 low profile attachment (OT Equator), 62 patients received 124 ball attachments, and 43 patients received 107 Locator attachments. In eighty-three patients the implants were splinted with computer aided design/computer aided manufacturing (CAD/CAM) or casted bar. At the last follow-up, 10 implants failed in eight patients. Statistical significance was found for failed prostheses (P = 0.0723) and complications (P = 0.0165), with better values for splinted implants. No statistically significant differences were found in proportion of implant and prosthetic failure (P > 0.05). At a five-year follow-up, proportion of complications (P = 0.0289) and failed prostheses (P = 0.0069) were statistically higher for IOV on Locator attachments. No difference was founded in MBL at one- and two-year follow-up between different attachment systems (P > 0.05). Statistically significant improvement in all the OHIP categories was reported in all the patients, after one year of function. Conclusions: Implant overdenture showed high implant and prosthetic survival rates, low complications, high patient satisfaction, and good biological parameters in the long-term follow-up. Splinting the implants may reduce number of mechanical complications. Locator attachments showed higher number of complications. Further studies are needed to confirm these preliminary results.


Prosthesis ◽  
2020 ◽  
Vol 2 (4) ◽  
pp. 352-361
Author(s):  
Marco Montanari ◽  
Roberto Scrascia ◽  
Gabriele Cervino ◽  
Massimo Pasi ◽  
Emiliano Ferrari ◽  
...  

Purpose: To evaluate preliminary data on survival and success rates of immediately loaded, screw-retained, restorations delivered on lower arches using narrow and low-profile OT Equator abutments. Methods: This retrospective study analyzed data of patients rehabilitated with OT Bridge (fixed prosthetic system built on OT Equator) prosthetic concept from November 2017 to February 2019 in five different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. Results: A total of 60 implants were inserted in 12 patients. Patients were followed for a mean period of 15.8 months (range 12–24). All the patients received OT Equator as intermediate abutments. Four out of 60 implants were connected to the prosthetic framework using only the Seeger system, without a screw. One year after loading, three implants failed (implant survival rate of 95.0%) in two patients. No prosthesis failed and no major biological and technical complications were experienced. One year after initial loading, the marginal bone level was 0.32 ± 0.2 mm. The OHIP before treatment was 87.7 ± 6.0. One year after treatment, OHIP was 23.6 ± 1.2. The difference was statistically significant (64.1 ± 7.2; p = 0.0000). One year after loading, 8.9% of the examined implant sites present positive bleeding on probing, while 5.8% of the implant sites presented plaque. Conclusions: The OT Equator abutments showed successful results when used to support mandible fixed dental prosthesis delivered on 4–6 implants. Whole prosthetic survival and success rates, high patient satisfaction, and good biological parameters were experienced one year after function. Further prospective studies are needed to confirm these preliminary results.


Author(s):  
Rosario Acampora ◽  
Marco Montanari ◽  
Roberto Scrascia ◽  
Emiliano Ferrari ◽  
Massimo Pasi ◽  
...  

Abstract Objective  Preliminary data on survival and success rates of immediately loaded, maxillary, screw-retained, implant-supported, fixed restorations delivered on narrow and low-profile OT Equator abutments (OT Bridge, Rhein’83) were evaluated. Materials and Methods This retrospective study evaluated data collected from patients rehabilitated with OT Bridge prosthetic concept between November 2017 and February 2019 in six different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. Results A total of 76 implants were inserted in 14 patients. Patients were followed for a mean period of 15.8 months (range = 12–24). All the patients receive OT Equator (Rhein'83) as intermediate abutments. One year after loading, one implant failed (1.3%). None of the prosthesis failed. One prosthetic complication was experienced in one patient. Three out of 76 implants were connected to the prosthetic framework using only the Seeger system, without screw. Difference in OHIP values was statistically significant (71.9 ± 8.5; p = 0.000). One year after loading, MBL was 0.21 ± 0.11 mm and p-value was 0.000. One year after loading, 8.7% of the examined implant sites present positive bleeding on probing, while 6.4% of the implant sites presented plaque. Conclusion The OT Equator abutments (Rhein'83) showed successful results when used to support maxillary fixed dental prosthesis delivered on four to six implants. High implant and prosthetic survival rates, very low complications, high patient satisfaction, and good biological parameters, including only 0.2 mm of bone remodeling were experienced one year after function. Further studies are needed to confirm these preliminary results.


2021 ◽  
Vol 11 (18) ◽  
pp. 8601
Author(s):  
Marco Tallarico ◽  
Gabriele Cervino ◽  
Marco Montanari ◽  
Roberto Scrascia ◽  
Emiliano Ferrari ◽  
...  

The purpose of this multicenter randomized controlled trial was to compare the clinical, radiographic, and patient-centered outcomes of early loaded mandibular overdentures deliberately placed on two or three implants. The outcomes were: implant and prosthesis success and survival rates; biological and technical complications; marginal bone loss; patient satisfaction; and periodontal parameters. The results showed no differences between the groups in any of the outcomes analyzed. With the limitations of the present study, and looking at long-term follow-up, the gold standard of prosthetic rehabilitations with attachments, in agreement with the scientific community, should prefer two non-splinted implants.


2013 ◽  
Vol 39 (5) ◽  
pp. 625-632 ◽  
Author(s):  
David Peñarrocha-Oltra ◽  
Eugenia Candel-Martí ◽  
Javier Ata-Ali ◽  
María Peñarrocha-Diago

We review the evidence-based literature on the use of tilted implants in the rehabilitation of patients with maxillary atrophy. Studies from 1999 to 2010 on patients with atrophic maxilla rehabilitated with tilted implants were reviewed. Clinical series with at least 10 patients rehabilitated using tilted implants and a follow-up of at least 12 months after prosthetic load were included. Case reports and studies with missing data were excluded. In each study the following was assessed: surgical technique, prosthesis type, timing of implant loading, success rate and marginal bone loss of tilted and axial implants, complications and patient satisfaction level. Thirteen studies were included, reporting a total of 782 tilted and 666 axial implants in 319 patients. Success rates went from 91.3% to 100% for axial implants and from 92.1% to 100% for tilted implants; radiographic marginal bone loss went from 0.4 mm to 0.92 mm in tilted implants and from 0.35 mm to 1.21 mm in axial implants. No statistically significant differences were found in any of the studies. No surgical complications and only minor prosthetic complications were reported. High patient satisfaction was found with all types of prosthesis (full-arch fixed, partial fixed and overdentures) placed over tilted implants. The literature on tilted implants shows that implants placed with this technique, both used alone and combined with axially placed implants, and rehabilitated with different prosthetic options have high success rates, minimal complications and high patient satisfaction. However, lack of homogeneity among studies and relatively short follow-up periods for most studies make necessary more studies.


2019 ◽  
Vol 45 (6) ◽  
pp. 503-508 ◽  
Author(s):  
Meng Ma ◽  
Mengxing Qi ◽  
Dongsheng Zhang ◽  
Hongchen Liu

The purpose of this study is to analyze 1- and 3-year clinical performances of narrow diameter implants (NDIs) versus regular diameter implants (RDIs). A search of electronic databases and a manual search was performed for the time period January 2000 to April 2018. A meta-regression was used to evaluate the effects of the “fixed effects” model on the implant survival rates, prosthesis success rates and marginal bone loss (MBL) with follow-up time of 1 year and 3 years. Of the 11 studies included, the overall combined 1-year implant survival rates were 98.14% for NDIs and 98.20% for RDIs. The overall combined 3-year implant survival rates were 98.71% for NDIs and 98.84% for RDIs. The corresponding values for 1-year prosthesis success rates were 96.94% for NDIs and 99.25% for RDIs. The corresponding values for 3-year prosthesis success rates were 89.25% for NDIs and 96.55% for RDIs. The meta-regression showed no significant differences between NDIs and RDIs regarding implant survival rates, prosthesis success rates, and MBL in 1-year and 3-year follow-up (P > .05). The results of this meta-analysis concluded that the implant diameter did not affect its survival rates, prosthesis success rates, and MBL in 1 and 3 years. The use of NDIs instead of bone augmentation procedures with RDIs did not affect its survival rates, prosthesis success rates, and MBL in the short-term and middle-term. However, more high-quality randomized controlled trials and long follow-up studies are needed on this topic.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Charlotte Jensen-Louwerse ◽  
Harjan Sikma ◽  
Marco S. Cune ◽  
Felix L. Guljé ◽  
Henny J. A. Meijer

Abstract Background The aim of this retrospective study was to evaluate the implant survival, clinical and radiographic outcomes, and patient satisfaction of single implant-supported two-unit cantilever fixed partial dentures in the posterior region. Methods Patients who received a single implant-supported fixed partial denture with a cantilever in the posterior region between January 2004 and February 2018 were included. Survival rate of the implants and the fixed partial dentures and data regarding the marginal bone level, presence of plaque, calculus, bleeding on probing, mucosa health, pocket probing depth, and patient satisfaction were collected during an evaluation visit. Complications were recorded from the medical records. Results Twenty-three patients (mean age 64 ± 13 years) with 28 implants could be included in the study. The mean follow-up period was 6.5 ± 4.8 years at the time of data collection. The survival rate of the implants and fixed partial dentures was 100%. Mean marginal bone loss for the mesial and distal side of the implants was 0.41 mm (SD 1.18 mm) and 0.63 mm (SD 0.98 mm) respectively. A high prevalence of peri-implant-mucositis (89.3%) and peri-implantitis (17.9%) was observed as well as a limited number of technical complications. Patients were quite satisfied, as reflected by a mean VAS score of 94.0 ± 7.2 points (range 0–100) and a OHIP-NL49 score of 10.8 (range 0–196). Conclusions Single implant-supported fixed partial dentures with a mesial or distal cantilever can be a predictable treatment option in the posterior region, with stable peri-implant bone levels, minor technical complications, and very content patients. However, the prevalence of peri-implant mucositis and peri-implantitis was high. Trial registration ISRCTN, ISRCTN79055740, Registered on March 14, 2021 – —Retrospectively registered.


2012 ◽  
Vol 38 (S1) ◽  
pp. 461-466 ◽  
Author(s):  
Eugenia Candel ◽  
David Peñarrocha ◽  
Maria Peñarrocha

The purpose of this article is to review the literature published and to assess the success of treatment of patients with atrophic posterior maxilla with pterygoid implants. Studies from 1992 to 2009 on patients with atrophic posterior maxilla rehabilitated with pterygoid implants were reviewed. Those reporting clinical series of at least 5 patients with atrophic posterior maxilla (Class IV and V of Cawood and Howell), rehabilitated with pterygoid implants and fixed prosthesis, and with 12 months minimum follow-up were included. In each study the following were assessed: number of patients, number of implants, surgical technique, prosthetic rehabilitation, success rate, bone loss, complications and patient satisfaction. Thirteen articles were included, reporting a total of 1053 pterygoid implants in 676 patients. The weighted average success of pterygoid implants was 90.7%; bone loss evaluated radiographically ranged between 0 and 4.5 mm. No additional complications compared with conventional implants were found, and patient satisfaction level with the prosthesis was high. Pterygoid implants have high success rates, similar bone loss levels to those of conventional implants, minimal complications and good acceptance by patients, being therefore an alternative to treat patients with atrophic posterior maxilla. Two anatomical locations in which implants are placed in the retromolar area can be distinguished: the pterygoid process and the pterygomaxillary region. Implant lengths and angulations vary between these two techniques.


2013 ◽  
pp. 154-158
Author(s):  
Angelo Zullo ◽  
Cesare Hassan ◽  
Francesca Cristofari ◽  
Claudia Iegri ◽  
Nicoletta Villiva ◽  
...  

The incidence of primary gastric lymphoma in Italy is considerably higher than that observed in the rest of Europe. It is widely accepted that gastric B-cell, low-grade mucosalassociated lymphoid tissue (MALT) lymphoma is caused by specific host-bacterial interactions that occur during Helicobacter pylori infection. This review examines recent findings on the origins, diagnosis, treatment, and follow-up of gastric MALT lymphomas. Clinical and endoscopic findings at diagnosis vary widely. In a substantial number of cases, the patient presents only vague dyspeptic symptoms or poorly defined abdominal pain with no macroscopic lesions on the gastric mucosa. Review of data from 32 trials in which a total of 1,387 MALT-lymphoma patients of the stomach were treated solely with H. pylori eradication revealed high remission rates when the disease is treated early (stage I-II1). Neoplasia confined to the submucosa, antral localization of tumors, and negativity for the API2-MALT1 translocation were associated with a high probability of remission following H. pylori eradication. When the latter approach is not sufficient, radiotherapy, chemotherapy and, in selected cases, surgery are associated with high success rates; data on the efficacy of monoclonal antibody therapy (rituximab) are still limited. Five-year survival rates are higher than 90%. Patients whose tumors have been eliminated require close, long-term endoscopic follow-up since recurrence has been reported in some cases. Broader clinical follow-up is also advisable because the incidence of other solid tumors and of cardiovascular events is reportedly increased in these patients.


2019 ◽  
Vol 45 (6) ◽  
pp. 434-443
Author(s):  
Alessandro Cucchi ◽  
Elisabetta Vignudelli ◽  
Simonetta Franco ◽  
Paolo Ghensi ◽  
Luciano Malchiodi ◽  
...  

The aim of this prospective study was to compare implant success rate and crestal bone loss around tilted and straight implants supporting immediate-loading full-arch rehabilitations. Twenty consecutive patients with edentulous jaws treated between June 2013 and July 2015 who satisfied all inclusion and exclusion criteria were included in the study. All patients were rehabilitated through a full-arch restoration supported by 4 or 6 immediately loaded implants. Clinical and radiographic examinations were scheduled every 12 months to evaluate implant success rates and crestal bone levels. Significant differences in crestal bone levels and success rates between straight and tilted implants were investigated by means of independent statistical analysis; differences were regarded as significant if P < .05. Seventy straight and 50 tilted implants were placed to rehabilitate 14 mandibles and 12 maxillae in 20 patients. After a follow-up of 12 to 36 months, survival rate was 97.1% for straight implants and 96.0% for tilted implants; while success rates were 94.3% and 94.0%, respectively. Success and survival rates were not significantly different (P > .05). Change in crestal bone level was 0.5 ± 0.4 mm for straight implants and 0.6 ± 0.4 mm for tilted implants (P > .05). Straight and tilted implants seemed to have similar behavior after immediate loading rehabilitations. After functional loading, straight and tilted implants did not differ significantly in clinical outcome.


Sign in / Sign up

Export Citation Format

Share Document