scholarly journals Quantitative Image Quality Metrics of the Low-Dose 2D/3D Slot Scanner Compared to Two Conventional Digital Radiography X-ray Imaging Systems

Diagnostics ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1699
Author(s):  
Ahmed Jibril Abdi ◽  
Bo R. Mussmann ◽  
Alistair Mackenzie ◽  
Oke Gerke ◽  
Benedikte Klaerke ◽  
...  

The aim of this study was to determine the quantitative image quality metrics of the low-dose 2D/3D EOS slot scanner X-ray imaging system (LDSS) compared with conventional digital radiography (DR) X-ray imaging systems. The effective detective quantum efficiency (eDQE) and effective noise quantum equivalent (eNEQ) were measured using chest and knee protocols. Methods: A Nationwide Evaluation of X-ray Trends (NEXT) of a chest adult phantom and a PolyMethylmethacrylate (PMMA) phantom were used for the chest and knee protocols, respectively. Quantitative image quality metrics, including effective normalised noise power spectrum (eNNPS), effective modulation transfer function (eMTF), eDQE and eNEQ of the LDSS and DR imaging systems were assessed and compared. Results: In the chest acquisition, the LDSS imaging system achieved significantly higher eNEQ and eDQE than the DR imaging systems at lower and higher spatial frequencies (0.001 > p ≤ 0.044). For the knee acquisition, the LDSS imaging system also achieved significantly higher eNEQ and eDQE than the DR imaging systems at lower and higher spatial frequencies (0.001 > p ≤ 0.002). However, there was no significant difference in eNEQ and eDQE between DR systems 1 and 2 at lower and higher spatial frequencies (0.10 < p < 1.00) for either chest or knee protocols. Conclusion: The LDSS imaging system performed well compared to the DR systems. Thus, we have demonstrated that the LDSS imaging system has the potential to be used for clinical diagnostic purposes.

Perception ◽  
1997 ◽  
Vol 26 (1_suppl) ◽  
pp. 81-81
Author(s):  
P G J Barten

In most image quality metrics (eg MTFA, ICS, SQF, DDD, SQRI) use is made of the modulation transfer function (MTF) of the imaging system and the contrast sensitivity function (CSF) of the human visual system. All metrics usually show a positive correlation with perceived image quality. This does not, however, say much about the correctness of the underlying equations. Defocusing experiments where an image is defocused by one just-noticeable difference can give information about the contribution of different spatial-frequency ranges to image quality. By performing defocusing experiments with images where contrast is also varied, information can be obtained about the dependence of image quality on contrast. In our investigation defocusing measurements from Baldwin (1940), Carlson and Cohen (1980) and Watt and Morgan (1983) were used. Comparison of the results with the fundamental dependence of some image quality metrics on spatial frequency and contrast indicates that only the SQRI (square-root integral) showed the right behaviour with respect to these parameters.


1975 ◽  
Author(s):  
A. E. Stewart

This paper discusses the development of a real-time high energy x-ray imaging system for use in dynamic fluoroscopy of aero gas turbines. In order to cover the range of subjects on gas turbines, over ten combinations of film and screen types are used. Three different types of x-ray imaging systems were considered for use: direct type intensifiers (cesium iodide phosphors), and indirect type intensifiers — Marconi “Marionette” and the Oude Delft “Delcalix.”


2018 ◽  
Vol 34 (S1) ◽  
pp. 17-18
Author(s):  
Martina Andellini ◽  
Francesco Faggiano ◽  
Roxana di Mauro ◽  
Pietro Derrico ◽  
Matteo Ritrovato

Introduction:Patients with adolescent idiopathic scoliosis frequently receive X-ray imaging at diagnosis and subsequent follow monitoring. To achieve the ALARA concept of radiation dose, a biplanar low-dose X-ray system (BLDS) has been proposed. The aim of the study is to gather evidence on safety, accuracy and overall effectiveness of a BLDS compared with CT scanning, in a pediatric population, in order to support the final decision on possible acquisition of such innovative diagnostic system.Methods:The new method Decision-oriented HTA (DoHTA) was applied to carefully assess the diagnostic technology. It was developed starting from the EUnetHTA Core Model® integrated with the analytic hierarchy process in order to identify all the relevant assessment aspects of the technology involved, identified from scientific literature, experts’ judgments and specific context analysis of Bambino Gesù Children's Hospital. A weight was associated to each assessment element and the alternatives’ ranking was defined.Results:This innovative system provides orthopedic images in standing or sitting position, being able to examine the spine and lower limbs under normal weight-bearing conditions. This system is recommended for particular clinical indications as scoliosis and other congenital deformities of the spine. It is able to acquire simultaneous posteroanterior and lateral images in a single scan without vertical distortion and with lower radiation exposure than CT scanning. 2D images acquired can be combined to obtain a 3D reconstruction scanning based on a semi-automated statistical model.Conclusions:The major advantages of BLDS are the relatively low dose of radiation and the possibility of obtaining a 3D reconstruction of the bones. Our preliminary results show that data on the clinical effectiveness are limited but the technical advancements of BLDS appear promising in terms of patient management and patient health outcomes associated with its use.


2014 ◽  
Vol 898 ◽  
pp. 614-617
Author(s):  
Rui Hong Li ◽  
Yue Ping Han

The present paper reviews the X-ray grating imaging systems at home and abroad from the aspects of technological characterizations and the newest researching focus. First, not only the imaging principles and the frameworks of the typical X-ray grating imaging system based on Talbot-Lau interferometry method, but also the algorithms of retrieving the signals of attenuation, refraction and small-angle scattering are introduced. Second, the system optimizing methods are discussed, which involves mainly the relaxing the requirement of high positioning resolution and strict circumstances for gratings and designing large field of view with high resolution. Third, two and four-dimensional grating-based X-ray imaging techniques are introduced.


1998 ◽  
Vol 14 (2) ◽  
pp. 75-83 ◽  
Author(s):  
Yoshiko Ariji ◽  
Jin-ichi Takahashi ◽  
Osamu Matsui ◽  
Tsuneichi Okano ◽  
Munetaka Naitoh ◽  
...  

1979 ◽  
Author(s):  
L. K. Wagner ◽  
G. Cohen ◽  
S. R. Amtey ◽  
F. A. DiBianca ◽  
R. G. Lester

2019 ◽  
Vol 185 (2) ◽  
pp. 252-265
Author(s):  
Ahmed Jibril Abdi ◽  
Bo Mussmann ◽  
Alistair Mackenzie ◽  
Benedikte Klaerke ◽  
Poul Erik Andersen

Abstract Purpose To assess and compare the radiation dose and image quality of the low dose 2D/3D EOS slot scanner (LDSS) to conventional digital radiography (DR) X-ray imaging systems for chest and knee examination protocols. Methods and materials The effective doses (ED) to the patient in the chest and knee clinical examination protocols for LDSS and DR X-ray imaging systems were determined using the dose area product and PCXMC Monte Carlo simulation software. The CDRAD phantom was imaged with 19 cm, and 13 cm thick Polymethyl Methacrylate (PMMA) blocks to simulate the chest and knees respectively of a patient of average adult size. The contrast detail resolution was calculated using image analysis software. Results The EDs for the LDSS default setting were up to 69% and 51% lower than for the DR systems for the chest (speed 4) and knee (speed 6) protocols, respectively, while for the increased dose level setting then the EDs were up to 42% and 35% lower than for the DR systems for the chest (speed 6) and knee (speed 8) protocols respectively. At the default setting, the contrast detail was lowest for the default setting of the 2D/3D low dose slot scanner (LDSS) for both chest and knee examinations, but at the highest dose levels then the threshold were equal or higher than the contrast resolution of DR imaging systems. Conclusion The LDSS has the potential to be used for clinical diagnosis of chest and knee examinations using the higher dose level. For speed 6 in chest protocol and speed 8 in knee protocol, the measured contrast detail resolution was comparable with the DR systems but at a lower effective dose.


Sign in / Sign up

Export Citation Format

Share Document