scholarly journals Neoteric Algorithm Using Cell Population Data (VCS Parameters) as a Rapid Screening Tool for Haematological Disorders

Diagnostics ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1652
Author(s):  
Angeli Ambayya ◽  
Jameela Sathar ◽  
Rosline Hassan

Hitherto, there has been no comprehensive study on the usefulness of cell population data (CPD) parameters as a screening tool in the discrimination of non-neoplastic and neoplastic haematological disorders. Hence, we aimed to develop an algorithm derived from CPD parameters to enable robust screening of neoplastic from non-neoplastic samples and subsequently to aid in differentiating various neoplastic haematological disorders. In this study, the CPD parameters from 245 subtypes of leukaemia and lymphoma were compared against 1103 non-neoplastic cases, and those CPD parameters that were vigorous discriminants were selected for algorithm development. We devised a novel algorithm: [(SD-V-NE*MN-UMALS-LY*SD-AL2-MO)/MN-C-NE] to distinguish neoplastic from non-neoplastic cases. Following that, the single parameter MN-AL2-NE was used as a discriminant to rule out reactive cases from neoplastic cases. We then assessed CPD parameters that were useful in delineating leukaemia subtypes as follows: AML (SD-MALS-NE and SD-UMALS-NE), APL (MN-V-NE and SD-V-MO), ALL (MN-MALS-NE and MN-LMALS-NE) and CLL (SD-C-MO). Prospective studies were carried out to validate the algorithm and single parameter, MN-AL2-NE. We propose these CPD parameter-based discriminant strategies to be adopted as an initial screening and flagging system in the preliminary evaluation of leukocyte morphology.

1994 ◽  
Vol 72 (01) ◽  
pp. 089-091 ◽  
Author(s):  
P de Moerloose ◽  
Ph Minazio ◽  
G Reber ◽  
A Perrier ◽  
H Bounameaux

SummaryD-dimer (DD), when measured by a quantitative enzyme-linked immunosorbent assay (ELISA), is a valuable test to exclude venous thromboembolism (VTE). However, DD ELISA technique is not appropriate for emergency use and the available agglutination latex assays are not sensitive enough to be used as an alternative to rule out the diagnosis of VTE. Latex assays could still be used as screening tests. We tested this hypothesis by comparing DD levels measured by ELISA and latex assays in 334 patients suspected of pulmonary embolism. All but one patient with a positive (DD ≥500 ng/ml) latex assay had DD levels higher than 500 ng/ml with the ELISA assay. Accordingly, ELISA technique could be restricted to patients with a negative result in latex assay. This two-step approach would have spared about 50% of ELISA in our cohort. In conclusion, our data indicate that a latex test can be used as a first diagnostic step to rule out pulmonary embolism provided a negative result is confirmed by ELISA and the performance of the latex assay used has been assessed properly.


2012 ◽  
Vol 12 (1) ◽  
Author(s):  
Caroline Marquer ◽  
Caroline Barry ◽  
Yoram Mouchenik ◽  
Sarah Hustache ◽  
Douma M Djibo ◽  
...  

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Shabbir Syed-Abdul ◽  
Rianda-Putra Firdani ◽  
Hee-Jung Chung ◽  
Mohy Uddin ◽  
Mina Hur ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document