scholarly journals Electromyography-Guided Adjustment of an Occlusal Appliance: Effect on Pain Perceptions Related with Temporomandibular Disorders. A Controlled Clinical Study

Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 667
Author(s):  
Simona Tecco ◽  
Vincenzo Quinzi ◽  
Alessandro Nota ◽  
Alessandro Giovannozzi ◽  
Maria Rosaria Abed ◽  
...  

Background: The purpose of this study is to evaluate the effect of an electromyography-guided adjustment of an occlusal appliance on the management of Temporomandibular disorder-related pain. Methods: Data from 40 adult patients (20 males and 20 females), who underwent treatment with occlusal appliances, were recorded. A total of 20 appliances were adjusted according to electromyographic data (group 1), while the others were adjusted by a clinical conventional procedure (group 2). Muscle pain to palpation, pain during articular movements and headache were recorded by a VAS score (from 0 to 100) before the beginning of treatment (T0), at T1 (4 weeks) and T2 (8 weeks). Results: Results showed a reduction of pain in both groups, with a better trend for group 1, where better results were achieved at T1 and maintained stability at T2, with an improved mean value regarding all parameters studied. After 8 weeks, only small recurrences started to occur in muscle pain to palpation in group 2. Conclusions: An occlusal appliance seems to be able to achieve a clinical improvement of Temporomandibular disorder (TMD)-related pain and headache, independently from the adjustment procedure adopted. However, the use of a surface electromyographic activity of masticatory muscles (sEMG) device as an aid in the calibration procedure seems to allow a better trend because the improvement of symptoms was obtained before, after the first four weeks, with an improvement in percentages of all the variables investigated. While the conventional procedure obtained later the improvement.

2013 ◽  
Vol 82 (4) ◽  
pp. 411-414
Author(s):  
Richard Chaloupka ◽  
Milan Dvořák ◽  
František Tichý ◽  
Jiří Veselý ◽  
Alois Nečas

The aim of this experimental study was to assess the spine development in growing rats following pinealectomy or partial sensorimotor cortical area damage. A total of 68 Wistar albino rats (Rattus norvegicus v. alba f. domestica) aged 3–4 weeks were divided into four groups. In group 1 (n = 22) pinealectomy was performed, in group 2 (n = 24) the sensorymotor cortical area 2 × 1 × 1 mm below the coronal suture was removed. Sham operation consisted of a craniotomy (n = 11) and a craniotomy with a durotomy (n = 11). All surgeries were performed from the left side. The rats were killed four months after surgery and radiography was then made. Scoliosis, C2-T7 lordosis and T7-S1 kyphosis were measured.The brains of rats after sensorimotor cortical area removal were isolated and investigated including histological examination (light microscope). Scoliosis of 9–14 degrees (mean value 10.8) was developed in five animals after pinealectomy; in rats after removal of the sensorimotor cortical area scoliosis of 10–24 degrees (mean value 15.9) was observed in eight animals. The scoliotic curves were non structural. Our results indicate the importance of cortical area damage, together with craniotomy and durotomy in the development of growing rat spine. These damages could cause a disorder of balance between smaller inhibitory and greater facilitating area of central nervous system, controlling the muscular tone and resulting in the development of increased lordosis and kyphosis and non structural scoliosis due to muscle imbalance. Thus the new hypothesis of scoliosis aetiology was introduced.


Author(s):  
Abhishek Salwan ◽  
Shakeen Singh

Background: Cystoid macular edema (CME) is the formation of fluid-filled cystoid spaces between the outer plexiform and inner nuclear layers of the retina. It may present as a complication of routine cataract surgery including phacoemulsification (PHACO) and small incision cataract surgery (SICS).Methods: An observational study of uncomplicated cataract surgery with assessment by ophthalmoscopy, slit Lamp, Snellen chart and OCT during pre- and post-operative period. 100 patients were selected by inclusion criteria and using convenient sampling technique and were divided into two groups of 50 each in PHACO and SICS groups.Results: During preoperative observation in SICS/group-1, mean value and SD of macular thickness was 223.38±12.61 and in PHACO/group-2 it was 224.14±12.69. Mean value, mean difference and p value of visual acuity in group 1 was 0.258, during 12 weeks 0.788 with mean difference -0.53 and p=0.000 and in group 2 it was 0.269, during 12 weeks 0.844 with mean difference -0.58 and p=0.000. Mean value, SD, mean difference and p value of macular thickness in SICS during 1 week was 238.28±12.29, during 12 weeks 227.04±12.58 with mean difference 11.24000 and p=0.000 and in PHACO mean value, SD, mean difference with p value during 1 week was 231.90±12.42, during 12 weeks was 225.02±11.74 with mean difference 6.88000 and p=0.000.Conclusions: A subclinical increase in post-operative macular thickness was recorded which returned nearly to baseline values during the 12 weeks follow up and did not affect visual outcome.


2021 ◽  
Vol 10 (1) ◽  
pp. 33-38
Author(s):  
Rajeev Raj Manandhar ◽  
Krishna Raj Khanal ◽  
Himal Khanal ◽  
Saroj Gautam

Background: The pain and limitation of shoulder function can disrupt daily activities of patients for months to years. Adhesive capsulitis is considered a self-limiting disease but the duration remains uncertain. The brunt of the disease is focussed on the inflamed joint capsule. On this basis, use of corticosteroid injection is justified. However, injection method is not conclusive. Objectives: To compare clinical benefits of intra-articular injection alone versus combined intra-articular and subacromial injections in management of adhesive capsulitis. Methods: Fifty-nine patients with diagnostic criteria for adhesive capsulitis were included in the study from March 2019 to September 2020. Patients were divided into two groups; patients who underwent intra-articular (IA) injection alone (Group 1) and those who received both intra-articular and sub-acromial (IA+SA) injection (Group 2). The injections were landmark guided. Patients were followed up at three, six, and 12 weeks. Pain was recorded using visual analogue scale (VAS) and subjective function using Constant-Murley score. Results: Twenty-eight patients were included in Group 1 (IA) and 31 in Group 2 (IA+SA). Thirty-six patients were female (18 each in Group 1 and Group 2) and 23 patients were male (Group 1 = 13; Group 2 = 10). In the twelfth week, VAS score was reduced in both the groups. On comparing the mean value of Constant-Murley score between the two groups there is significant difference in value recorded at the sixth and twelfth week. Conclusion: The IA+SA injection provides significant reduction in pain and better function in the short term over the IA injection.


Author(s):  
Bhupender Yadav ◽  
Puja Malhotra ◽  
Harish Yadav ◽  
Sumit Singh Phukela

ABSTRACT Retention in mandibular dentures has always been a challenge for the treating dentist. Denture adhesives are known to improve the adhesive bond between the denture and the underlying tissues. However, denture adhesives still remain unexplored and not much is known about the efficacy of these materials in mandibular dentures especially in patients with poor foundations. The present study was carried out to compare the efficacy of different commercially available denture adhesives in relation to their retentive ability in patients with good well formed mandibular ridges and in patients with resorbed and flat mandibular ridges. Seventy edentulous patients, age range between 50 to 70 years, were selected. The patients were divided into 2 groups; group 1 comprised of 35 patients with good well formed mandibular ridges and group 2 consisted of 35 patients having low well rounded mandibular ridges. The adhesion and cohesion that developed between the dentures and the underlying tissues when the various materials were interposed between them was evaluated with the help of a test apparatus in newtons. Mean value of retention in denture without adhesive was 9.93 N and 24.53 N in resorbed and well formed ridges respectively. Use of denture adhesive materials led to a higher value of retention as opposed to when the dentures were used without adhesives. This was true for patients with good well formed mandibular ridges as well as for patients with poor foundations. Among the various denture adhesive powders tested, Fittydent showed better results, i.e. 29.56 and 33.05 in resorbed and well-formed ridges respectively as opposed to fixon which showed values of 16.47 and 27.70 respectively. How to cite this article Malhotra P, Yadav B, Yadav H, Phukela SS. A Clinical Study to assess the Efficacy of Commonly Available Denture Adhesive Materials in Mandibular Dentures. Int J Prosthodont Restor Dent 2013;3(4):125-130.


Author(s):  
Mona Sohrabi ◽  
Sara Ghadimi ◽  
Bahman Seraj

Objectives: This study aimed to assess the microleakage of Pedo Jacket crowns compared to stainless steel crowns (SSCs) cemented with different luting cements. Materials and Methods: In this in-vitro experimental study, 80 primary molars were randomly divided into four groups of 20 each. Groups 1 and 2 were subjected to standard tooth preparation for SSC. Crowns in group 1 were cemented with glass ionomer (GI), and crowns in group 2 were cemented with a resin-modified glass ionomer (RMGI) cement. In groups 3 and 4, minimal tooth preparation was performed for Pedo Jacket crowns, and the crowns were cemented with RMGI and Panavia resin cement, respectively. Microleakage was measured at mesial and distal surfaces in micrometers (µm), and the mean value for each tooth was calculated. One-way analysis of variance (ANOVA) was applied to compare the microleakage of the four groups. Results: Group 3 (Pedo Jacket cemented with RMGI) showed the highest microleakage (1523.83±250.32 µm) with significant differences with the remaining three groups (P<0.001). Microleakage in group 4 (Pedo Jacket cemented with Panavia) was significantly lower than that in the other three groups (301.25±219.53 µm, P<0.001). Groups 1 (SSCs cemented with GI) and 2 (SSCs cemented with RMGI) were not significantly different in terms of microleakage (P=0.49) although group 1 showed slightly higher microleakage than group 2 (598.43±260.85 µm versus 500.25±124.74 µm). Conclusions: Pedo Jacket crowns can serve as an acceptable esthetic alternative to SSCs if cemented with resin cements.  