scholarly journals Performance of a Noninvasive Time-Harmonic Elastography Technique for Liver Fibrosis Evaluation Using Vibration Controlled Transient Elastography as Reference Method

Diagnostics ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 653
Author(s):  
Tudor Voicu Moga ◽  
Ioan Sporea ◽  
Raluca Lupușoru ◽  
Alina Popescu ◽  
Alexandru Popa ◽  
...  

Aim: This study aimed to evaluate the diagnosis performance of time-harmonic elastography (THE) technique in real life in assessing liver fibrosis, considering vibration-controlled transient elastography (VCTE) as a reference method. Material and Method: We prospectively evaluated outpatients from the gastroenterology department. Liver stiffness (LS) was measured by the THE system by dedicated operators, and by VCTE by experienced operators. The diagnostic accuracy of THE in staging liver fibrosis was assessed. We also performed an intra- and interobserver reproducibility sub-analysis on a sub-group of 27 subjects, where liver stiffness measurements (LSM) were performed by a novice, an elastography expert, and an ultrasound expert. Results: Of the 165 patients, using VCTE cut-off values, 49.6% were F0-F1, 15.7% were F2, 6.6% were F3, and 28.1% were F4. A direct, significant and strong correlation (r = 0.82) was observed between LSM assessed by VCTE and THE, p < 0.0001. The cut-off for ruling out liver cirrhosis (LC) by THE on our study group was <1.61 m/s (7.77 kPa)–AUROC = 0.90 [95% CI (0.82–0.93)], Se = 90.7%, Sp = 66.6%, PPV = 55.7%, NPV = 93.9%. The cut-off for ruling in LC by THE was >1.83 m/s (10 kPa)-AUROC = 0.90 [95% CI (0.82–0.93)], p < 0.0001, Se = 65.1%, Sp = 96.7%, PPV = 90.3%, NPV = 85.7%. The overall agreement between examiners was excellent: 0.94 (95% CI: 0.89–0.97); still, the ICCs were higher for the more experienced elastography examiner: 0.92 (95% CI: 0.82–0.96) vs. 0.94 (95% CI: 0.87–0.97) vs. 0.97 (95% CI: 0.95–0.99). Conclusions: THE is a feasible and reproducible elastography technique that can accurately rule in and rule out advanced liver disease.

2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Ivica Grgurevic ◽  
Nermin Salkic ◽  
Sanda Mustapic ◽  
Tomislav Bokun ◽  
Kristian Podrug ◽  
...  

Aims. To investigate morbidity and mortality in a real-life cohort of patients with type 2 diabetes (T2D) in relation to prevalence and severity of nonalcoholic fatty liver disease (NAFLD). Methods. Patients with T2D were referred for assessment of liver fibrosis by the FIB-4 test and liver stiffness measurement (LSM) by vibration-controlled transient elastography (VCTE). Liver steatosis was quantified by the controlled attenuation parameter (CAP). These patients were followed until death or censored date. Results. Among 454 patients (52% males, mean age 62.5 years, BMI 30.9 kg/m2), 82.6% was overweight, 77.8% had fatty liver, and 9.9% and 3.1% had LSM and FIB-4 values suggestive of advanced fibrosis, respectively. During the follow-up period of median 2 years, 106 (23%) patients experienced adverse event (11% cardiovascular) and 17 (3.7%) died, whereas no liver-related morbidity or mortality was observed. Independent predictors of adverse outcomes were age and higher platelet count, while FIB-4, LSM, and CAP were not. Conclusion. In a cohort of T2D patients, no liver-related morbidity or mortality occurred during 2 years. Our patients probably have low real prevalence of advanced fibrosis which is likely overestimated by LSM ≥ 9.6 kPa. Liver fibrosis may be safely reassessed in the 2 years interval in noncirrhotic patients with T2D.


2017 ◽  
Vol 19 (2) ◽  
pp. 143 ◽  
Author(s):  
Felix Bende ◽  
Ioan Sporea ◽  
Roxana Sirli ◽  
Alina Popescu ◽  
Ruxandra Mare ◽  
...  

Aim: To evaluate the performance of 2D shear-wave elastography from General Electric (2D-SWE.GE) for the noninvasiveassessment of liver fibrosis and to identify liver stiffness (LS) cut-off values for predicting different stages of fibrosisusing Transient Elastography (TE) as the reference method. Material and method: We included 331 consecutive subjectswith or without chronic hepatopathies in whom LS was evaluated in the same session by means of 2 elastographic techniques:TE and 2D-SWE.GE. Reliable LS measurements were defined for TE as the median value of 10 measurements with a successrate of ≥60% and an interquartile range (IQR)<30% and for 2D-SWE.GE as the median value of 10 measurements acquiredin a homogenous area and an IQR<30%. To discriminate between TE fibrosis stages we used the following cut-offs: F2- 7;F3- 9.5 and F4- 12kPa. Results: Reliable LS measurements were obtained in 95.8% subjects by 2D-SWE.GE, and 94.2%by TE (p=0.44). Based on TE cut-off values we divided our cohort into four groups: F<2: 30.1%; F=2: 10.2%; F=3: 12.2%;F=4: 47.5%. A strong correlation was found between the LS values obtained by the 2 methods: r=0.83, p<0.0001.LS valuesobtained by 2D-SWE.GE were significantly lower than those obtained by TE: 10.14±4.24 kPa vs. 16.72±13.4 kPa (p<0.0001).The best cut-off value for F≥2, F≥3 and for F=4 were 6.7, 8.2 and 9.3 kPa. Conclusions: The best 2D-SWE.GE cut-off valuesfor predicting F≥2, F≥3 and F=4 were 6.7, 8.2 and 9.3kPa.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 783
Author(s):  
Alexandru Popa ◽  
Felix Bende ◽  
Roxana Șirli ◽  
Alina Popescu ◽  
Victor Bâldea ◽  
...  

Non-alcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide. This study aimed to evaluate the performance of four ultrasound-based techniques for the non-invasive multiparametric (MPUS) assessment of liver fibrosis (LF), steatosis (HS), and inflammation in patients with NAFLD. We included 215 consecutive adult patients with NAFLD (mean age: 54.9 ± 11.7; 54.5% were male), in whom LF, HS, and viscosity were evaluated in the same session using four new ultrasound-based techniques embedded on the Aixplorer MACH 30 system: ShearWave Elastography (2D-SWE.PLUS), Sound Speed Plane-wave UltraSound (SSp.PLUS), Attenuation Plane-wave UltraSound (Att.PLUS), and Viscosity Plane-wave UltraSound (Vi.PLUS). Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) (FibroScan) were considered as control. All elastographic measurements were performed according to guidelines. Valid liver stiffness measurements (LSM) were obtained in 98.6% of patients by TE, in 95.8% of patients by 2D-SWE.PLUS/Vi.PLUS, and in 98.1% of patients by Att.PLUS/SSp.PLUS, respectively. Therefore, 204 subjects were included in the final analysis. A strong correlation between LSMs by 2D-SWE.PLUS and TE (r = 0.89) was found. The best 2D-SWE.PLUS cut-off value for the presence of significant fibrosis (F ≥ 2) was 7 kPa. Regarding steatosis, SSp.PLUS correlated better than Att.PLUS with CAP values: (r = −0.74) vs. (r = 0.45). The best SSp.PLUS cut-off value for predicting the presence of significant steatosis was 1524 m/s. The multivariate regression analysis showed that Vi.PLUS values were associated with BMI and LSM by 2D-SWE.PLUS. In conclusion, MPUS was useful for assessing fibrosis, steatosis, and inflammation in a single examination in patients with NAFLD.


2020 ◽  
Vol 1 (1) ◽  
pp. 7
Author(s):  
Ioan Sporea ◽  
Felix Bende ◽  
Alina Popescu ◽  
Raluca Lupusoru ◽  
Renata Fofiu ◽  
...  

Aim: To evaluate the range of liver stiffness (LS) cut-off values for predicting different stages of liver fibrosis (LF) for 2D-SWE-GE implemented on three different systems from General Electric Healthcare (LOGIQ E9, LOGIQ S8, LOGIQ P9).Material and method: We performed a comparative study evaluating the performance of 2D-SWE-GE (LOGIQ E9, S8, P9) for predicting different stages of LF using Transient Elastography (TE) as the reference method. All patients (with or without chronic hepatopathies) were evaluated by TE, 331 patients were included in the LOGIQ E9 study, 179 in the LOGIQ S8 study and 234 in the LOGIQ P9 study. Reliable liver stiffness measurements (LSM) were defined for TE as the median value of 10 measurements with an interquartile range/median ratio (IQR/M)≤0.30 and for 2D-SWE-GE as the median value of 10 measurements and IQR/M≤0.30.Results: Reliable LSM was obtained by both methods in 91.5% subjects of the LOGIQ E9 group, in 95.5% subjects from the LOGIQ S8 group and in 87.6% subjects in the LOGIQ P9 group. The performance of 2DSWE-GE for predicting F≥2 with LOGIQ E9, LOGIQ S8 and LOGIQ P9 systems were: cut-offs 6.7 kPa, 6.9 kPa and 6.8 kPa; AUCs 0.95, 0.92 and 0.93. For predicting F≥3, the performances were: cut-offs – 8.2 kPa, 8.2 kPa and 7.6 kPa; AUCs - 0.97, 0.93 and 0.94. For predicting F4, the performances were: cut-offs – 9.3 kPa, 9.3 kPa and 9.3 kPa; AUCs - 0.96, 0.91 and 0.91.Conclusion: The LS cut-off values for 2D-SWE-GE implemented on different systems for predicting F≥2, F≥3 and F=4 are not significantly different.


2020 ◽  
Vol 1 (1) ◽  
pp. 13 ◽  
Author(s):  
Camelia Gianina Foncea ◽  
Alina Popescu ◽  
Raluca Lupusoru ◽  
Renata Fofiu ◽  
Roxana Sirli ◽  
...  

Aim: To evaluate the feasibility of two elastographic methods, point Shear Wave Elastography (pSWE) and two dimensional Shear Wave Elastography (2D-SWE), integrated in the same ultrasound machine, for liver fibrosis (LF) assessment, using Transient Elastography (TE) as the reference method.Material and methods: We included in the study 115 subjects in which LF was evaluated in the same session by TE (FibroScan, EchoSens), pSWE and 2D-SWE (Samsung-Medison RS85). Reliable liver stiffness (LS) measurements were defined: for TE the median value of 10 measurements with interquartile range (IQR/M)≤30%,while for pSWE and 2D-SWE the median value of 10 measurements, with a reliability measurement index (RMI)≥0.5 and IQR/M≤30%. For classification of LF severity we used TE as the reference method with the following cut-offs: F2≥7kPa, F3≥9.5kPa and F4≥12kPa.Results: Reliable measurements by TE were obtained in 98.2% of cases (113/115), by pSWE in 93.9% of cases (108/115) and by 2D-SWE in 92.1% of cases (106/115), so the final analysis included 101 patients. We divided the cohort into 3 groups: fibrosis 5.9 kPa [AUROC=0.95, 95%CI(0.89;0.98), p<0.0001, Se=94.1%, Sp=89.5%, PPV=82.1%, NPV=96.8%]; F4 LS >8 kPa [AUROC=0.98, 95%CI(0.94;0.99), p<0.0001, Se=94.4%, Sp=95.1%, PPV=81%, NPV=98.7%], while for 2D-SWE they were: F≥2 LS >6.1 kPa [AUROC=0.93, 95%CI(0.86;0.97), p<0.0001, Se=91.1%, Sp=80.6%, PPV=70.5%, NPV=94.7%]; F4 LS >7.6 kPa [AUROC=0.98, 95%CI(0.93;0.99), p<0.0001, Se=100%, Sp=91.5%, PPV=72%, NPV=100%]. We observed strong correlations between LS values obtained by TE and 2D-SWE (r=0.85), between TE and pSWE (r=0.88) and between pSWE and 2D-SWE (r=0.90) (p=0.37), respectively. There were no significant differences between the mean values obtained by pSWE and 2D-SWE (p=0.96).Conclusion: The pSWE and 2D-SWE are feasible methods for assessing liver fibrosis, both techniques strongly correlating with TE results.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 640.1-640
Author(s):  
S. J. Choi ◽  
J. S. Lee ◽  
S. H. Nam ◽  
W. J. Seo ◽  
J. S. Oh ◽  
...  

Background:Methotrexate (MTX) is a cornerstone drug for the treatment of rheumatic disease and low doses of MTX are both tolerable and safe, with monitored toxicity, assessed via the liver function test. However, there is still controversy regarding the risk of liver fibrosis with long-term use of MTX. Transient elastography is commonly used to assess and monitor fibrosis progression in patients with chronic liver disease.Objectives:The present study aims to investigate liver fibrosis using transient elastography and related factors in patients with rheumatic disease receiving long-term MTX.Methods:The present retrospective, longitudinal, cross-sectional study included patients with an autoimmune disease who are taking cumulative MTX dosed over 7 g, and who had liver fibrosis upon examination using transient elastography. Liver fibrosis was defined as liver stiffness, valued over 7.2 kPa. Logistic regression analysis was performed to identify factors associated with liver fibrosis, and receiver operating characteristics analysis was used to determine the predictive value of each factor.Results:We included 83 patients with autoimmune disease, with a median MTX cumulative dose of 11.6 (range 7.3-16.0) g. Sixty-eight patients (81.9%) had rheumatoid arthritis (RA), and 13 patients (15.7%) had Takayasu arteritis. The median MTX exposure duration was 18 (range 9-31) years. The median liver stiffness value was 4 (range 1.8-10.2) kPa. Five patients (6%) showed liver fibrosis (3 patients; RA, 2 patients; Takayasu arteritis). In the linear regression analysis, cumulative MTX dose showed a tendency towards a positive correlation with increasing liver stiffness value (r2 =0.039, p = 0.074). In the logistic regression analysis, cumulative MTX dose was associated with a higher risk of liver fibrosis (OR: 1.734, 95% CI: 1.060–2.837, p = 0.029). In addition, cumulative MTX dose had an area under the curve (AUC) of 0.813 (95% CI 0.695-0.930) and a sensitivity of 80% and specificity of 71.8% at a cut-off value of 12.7 g.Conclusion:Liver fibrosis was observed in 6% of patients with long-term MTX use and higher cumulative MTX doses increased the risk of liver fibrosis. Thus, transient elastography should be considered in patients exposed to high cumulative doses of MTX.Disclosure of Interests:None declared


2021 ◽  
Vol 75 (2) ◽  
pp. 125-133
Author(s):  
Soňa Franková ◽  
Jan Šperl

Portal hypertension represents a wide spectrum of complications of chronic liver diseases and may present by ascites, oesophageal varices, splenomegaly, hypersplenism, hepatorenal and hepatopulmonary syndrome or portopulmonary hypertension. Portal hypertension and its severity predicts the patient‘s prognosis: as an invasive technique, the portosystemic gradient (HPVG – hepatic venous pressure gradient) measurement by hepatic veins catheterisation has remained the gold standard of its assessment. A reliable, non-invasive method to assess the severity of portal hypertension is of paramount importance; the patients with clinically significant portal hypertension have a high risk of variceal bleeding and higher mortality. Recently, non-invasive methods enabling the assessment of liver stiffness have been introduced into clinical practice in hepatology. Not only may these methods substitute for liver biopsy, but they may also be used to assess the degree of liver fibrosis and predict the severity of portal hypertension. Nowadays, we can use the quantitative elastography (transient elastography, point shear-wave elastrography, 2D-shear-wave elastography) or magnetic resonance imaging. We may also assess the severity of portal hypertension based on the non-invasive markers of liver fibrosis (i.e. ELF test) or estimate clinically signifi cant portal hypertension using composite scores (LSPS – liver spleen stiff ness score), based on liver stiffness value, spleen diameter and platelet count. Spleen stiffness measurement is a new method that needs further prospective studies. The review describes current possibilities of the non-invasive assessment of portal hypertension and its severity.


QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Mohammed F Montasser ◽  
Eman M Barakat ◽  
Mohamed S Ghazy ◽  
Sara M Abdelhakam ◽  
Hend E Ebada ◽  
...  

Abstract Aim of the work To test the reliability of fibroscan in detection of fibrosis in patients with Budd Chiari syndrome before and after endovascular intervention (after elimination of hepatic congestion). Background transient elastography (TE) is a noninvasive methodology that has been used to monitor liver stiffness in patients with chronic viral hepatitis. One of the limitations for accurate assessment of liver fibrosis by TE is the liver congestion. Liver congestion can result from Budd Chiari syndrome (BCS).The treatment of BCS is through restoring the flow of the blood between the portal vein to the inferior vena cava, which will lead to decongestion of the liver.TE, will be tested after liver decongestion for proper detection of liver fibrosis. Patients and methods This was a prospective cohort study conducted on 25 Egyptian patients with confirmed diagnosis of primary Budd-Chiari Syndrome (BCS) in the period from June 2017 to September 2019. TE was performed three days before endovascular intervention and three months after it. Liver biopsy was taken during the intervention for assessment of METAVIR score. Comparison was done between TE assessments before and after intervention in detection of the degree of liver fibrosis in comparison to METAVIR score measured in liver biopsy. Results FVLM was the most common hypercoagulable cause in the involved patients. There was significant drop in Liver Stiffness Measurements (LSM) measured three months post-intervention indicating improvement of liver fibrosis after relieving liver congestion but still not correlated to the METAVIR scores measured in the liver biopsy. Conclusion Liver congestion has high impact on Liver stiffness measurement giving overestimation which improves significantly after decongestion of the liver by the endovascular intervention.