scholarly journals Somatostatin Receptor PET/CT Imaging for the Detection and Staging of Pancreatic NET: A Systematic Review and Meta-Analysis

Diagnostics ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 598 ◽  
Author(s):  
Matteo Bauckneht ◽  
Domenico Albano ◽  
Salvatore Annunziata ◽  
Giulia Santo ◽  
Priscilla Guglielmo ◽  
...  

We investigated the diagnostic performance of Somatostatin Receptor Positron Emission Tomography/Computed Tomography (SSR-PET/CT) for the detection of primary lesion and initial staging of pancreatic neuroendocrine tumors (pNETs). A comprehensive literature search up to January 2020 was performed selecting studies in presence of: sample size ≥10 patients; index test (i.e., 68Ga-DOTATOC or 68Ga-DOTANOC or 68Ga-DOTATATE PET/CT); and outcomes (i.e., detection rate (DR), true positive, true negative, false positive, and false-negative). The methodological quality was evaluated with QUADAS-2. Pooled DR and pooled sensitivity and specificity for the identification of the primary tumor were assessed by a patient-based and a lesion-based analysis. Thirty-eight studies were selected for the qualitative analysis, while 18 papers were included in the meta-analysis. The number of pNET patients ranged from 10 to 142, for a total of 1143 subjects. At patient-based analysis, the pooled sensitivity and specificity for the assessment of primary pNET were 79.6% (95% confidence interval (95%CI): 71–87%) and 95% (95%CI: 75–100%) with a heterogeneity of 59.6% and 51.5%, respectively. Pooled DR for the primary lesion was 81% (95%CI: 65–90%) and 92% (95%CI: 80–97%), respectively, at patient-based and lesion-based analysis. In conclusion, SSR-PET/CT has high DR and diagnostic performances for primary lesion and initial staging of pNETs.

Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 304
Author(s):  
Giuseppina Biscontini ◽  
Cinzia Romagnolo ◽  
Chiara Cottignoli ◽  
Andrea Palucci ◽  
Fabio Massimo Fringuelli ◽  
...  

Background: to explore the diagnostic accuracy of 18F-Fluciclovine positron-emission tomography (PET) in prostate cancer (PCa), considering both primary staging prior to radical therapy, biochemical recurrence, and advanced setting. Methods: A systematic web search through Embase and Medline was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Studies performed from 2011 to 2020 were evaluated. The terms used were “PET” or “positron emission tomography” or “positron emission tomography/computed tomography” or “PET/CT” or “positron emission tomography-computed tomography” or “PET-CT” and “Fluciclovine” or “FACBC” and “prostatic neoplasms” or “prostate cancer” or “prostate carcinoma”. Only studies reporting about true positive (TP), true negative (TN), false positive (FP) and false negative (FN) findings of 18F-fluciclovine PET were considered eligible. Results: Fifteen out of 283 studies, and 697 patients, were included in the final analysis. The pooled sensitivity for 18F-Fluciclovine PET/CT for diagnosis of primary PCa was 0.83 (95% CI: 0.80–0.86), the specificity of 0.77 (95% CI: 0.74–0.80). The pooled sensitivity for preoperative LN staging was 0.57 (95% CI: 0.39–0.73) and specificity of 0.99 (95% CI: 0.94–1.00). The pooled sensitivity for the overall detection of recurrence in relapsed patients was 0.68 (95% CI: 0.63–0.73), and specificity of 0.68 (95% CI: 0.60–0.75). Conclusion: This meta-analysis showed promising results in term of sensitivity and specificity for 18F-Fluciclovine PET/CT to stage the primary lesion and in the assessment of nodal metastases, and for the detection of PCa locations in the recurrent setting. However, the limited number of studies and the broad heterogeneity in the selected cohorts and in different investigation protocols are limitation affecting the strength of these results.


2021 ◽  
Vol 10 (7) ◽  
pp. 1543
Author(s):  
Morwenn Le Boulc’h ◽  
Julia Gilhodes ◽  
Zara Steinmeyer ◽  
Sébastien Molière ◽  
Carole Mathelin

Background: This systematic review aimed at comparing performances of ultrasonography (US), magnetic resonance imaging (MRI), and fluorodeoxyglucose positron emission tomography (PET) for axillary staging, with a focus on micro- or micrometastases. Methods: A search for relevant studies published between January 2002 and March 2018 was conducted in MEDLINE database. Study quality was assessed using the QUality Assessment of Diagnostic Accuracy Studies checklist. Sensitivity and specificity were meta-analyzed using a bivariate random effects approach; Results: Across 62 studies (n = 10,374 patients), sensitivity and specificity to detect metastatic ALN were, respectively, 51% (95% CI: 43–59%) and 100% (95% CI: 99–100%) for US, 83% (95% CI: 72–91%) and 85% (95% CI: 72–92%) for MRI, and 49% (95% CI: 39–59%) and 94% (95% CI: 91–96%) for PET. Interestingly, US detects a significant proportion of macrometastases (false negative rate was 0.28 (0.22, 0.34) for more than 2 metastatic ALN and 0.96 (0.86, 0.99) for micrometastases). In contrast, PET tends to detect a significant proportion of micrometastases (true positive rate = 0.41 (0.29, 0.54)). Data are not available for MRI. Conclusions: In comparison with MRI and PET Fluorodeoxyglucose (FDG), US is an effective technique for axillary triage, especially to detect high metastatic burden without upstaging majority of micrometastases.


2021 ◽  
Vol 8 ◽  
Author(s):  
Jiale Hou ◽  
Yi Yang ◽  
Na Chen ◽  
Dengming Chen ◽  
Shuo Hu

Purpose: A meta-analysis was conducted to investigate the value of the volume parameters based on somatostatin receptor (SSTR)-positron emission tomography (PET) in predicting the prognosis in patients with neuroendocrine tumors (NETs).Material: PUBMED, EMBASE, Cochrane library, and Web of Knowledge were searched from January 1990 to May 2021 for studies evaluating prognostic value of volume-based parameters of SSTR PET/CT in NETs. The terms used were “volume,” “positron emission tomography,” “neuroendocrine tumors,” and “somatostatin receptor.” Pooled hazard ratio (HR) values were calculated to assess the correlations between volumetric parameters, including total tumor volume (TTV) and total-lesion SSTR expression (TL-SSTR), with progression-free survival (PFS) and overall survival (OS). Heterogeneity and subgroup analysis were performed. Funnel plots, Begg's and Egger's test were used to assess possible underlying publication bias.Results: Eight eligible studies involving 593 patients were included in the meta-analysis. In TTV, the pooled HRs of its prognostic value of PFS and OS were 2.24 (95% CI: 1.73–2.89; P < 0.00001) and 3.54 (95% CI, 1.77–7.09; P = 0.0004), respectively. In TL-SSTR, the pooled HR of the predictive value was 1.61 (95% CI, 0.48–5.44, P = 0.44) for PFS.Conclusion: High TTV was associated with a worse prognosis for PFS and OS in with patients NETs. The TTV of SSTR PET is a potential objective prognosis predictor.


2016 ◽  
Vol 58 (5) ◽  
pp. 558-564 ◽  
Author(s):  
Leilei Yuan ◽  
Jun Liu ◽  
Ying Kan ◽  
Jigang Yang ◽  
Xufu Wang

Background 99mTc-sestamibi (MIBI) parathyroid SPECT is generally regarded as the best preoperative localizing method in patients with hyperparathyroidism (HPT). However, 99mTc-MIBI SPECT is false negative in approximately 25% of adenomas. 11C-methionine positron emission tomography (PET) has been used in HPT with negative 99mTc-MIBI SPECT scan results. Purpose To systematically review and conduct a meta-analysis of published data on the performance of 11C-methionine PET in patients with HPT with negative 99mTc-MIBI SPECT. Material and Methods A comprehensive review of the literature was performed. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT and a negative 99mTc-MIBI SPECT was calculated on a per-patient basis using receiver-operating characteristic (ROC) methodology. Results Nine studies that met all inclusion and exclusion criteria were included into our meta-analysis, comprising a total sample size of 137 patients. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT with negative or inconclusive 99mTc-MIBI SPECT scans was 86% and 86%, respectively. The area under the ROC curve was 0.87. Conclusion By merit of the high overall sensitivity, specificity, and accuracy, 11C-methionine PET can potentially complement the diagnostic workup of patients with HPT and negative or inconclusive 99mTc-MIBI SPECT. 11C-methionine PET appears to be a promising diagnostic modality in complicated cases with HPT.


2019 ◽  
Vol 34 (2) ◽  
pp. 306-314
Author(s):  
Do Hyun Kim ◽  
Youngjun Seo ◽  
Kyung Min Kim ◽  
Seoungmin Lee ◽  
Se Hwan Hwang

Background We evaluated the accuracy of nasal endoscopy in diagnosing chronic rhinosinusitis (CRS) compared with paranasal sinus computed tomography (CT). Methods Two authors independently searched the 5 databases (PubMed, SCOPUS, Embase, the Web of Science, and the Cochrane database) up to March 2019. For all included studies, we calculated correlation coefficients between the endoscopic and CT scores. We extracted data on true-positive and false-positive and true-negative and false-negative results. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool (version 2). Results We included 16 observational or retrospective studies. A high correlation ( r = .8543; 95% confidence interval [CI] [0.7685–0.9401], P < .0001, I2 = 76.58%) between endoscopy and CT in terms of the diagnostic accuracy for CRS was apparent. The odds ratio (Lund–Kennedy endoscopic score ≥1) was 7.915 (95% CI [4.435–14.124]; I2 = 28.361%). The area under the summary receiver operating characteristic curve was 0.765. The sensitivity and specificity were 0.726 (95% CI [0.584–0.834]) and 0.767 (95% CI [0.685–0.849]), respectively. However, high interstudy heterogeneity was evident given the different endoscopic score thresholds used (Lund–Kennedy endoscopic score ≥1 vs 2). In a subgroup analysis of studies using a Lund–Kennedy endoscopic score threshold ≥2, the area under the summary curve was 0.881, and the sensitivity and specificity were 0.874 (95% CI [0.783–0.930]) and 0.793 (95% CI [0.366–0.962]), respectively. Conclusion Nasal endoscopy is a useful diagnostic tool; the Lund–Kennedy score was comparable with that of CT.


2018 ◽  
Vol 59 (12) ◽  
pp. 1466-1474 ◽  
Author(s):  
Ying Kan ◽  
Shuxin Zhang ◽  
Wei Wang ◽  
Jie Liu ◽  
Jigang Yang ◽  
...  

Background Metastatic pheochromocytoma and paraganglioma (PCs/PGLs) show high germline mutation, and 18F-FDG and 68Ga-DOTA peptide positron emission tomography/computed tomography (PET/CT) imaging are recommended for the diagnosis of metastatic of PCs. However, there has been lack of direct comparison of the two modalities in the diagnosis of metastatic of PCs up to now. Purpose To evaluate and compare the value of localization of 68Ga-somatostatin receptor analogs and 18F-FDG in the diagnosis of metastatic PCs/PGLs. Material and Methods A comprehensive literature search of PubMed/MEDLINE, ScienceDirect, and Web of Science was performed in accordance with the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) guidelines published in August 2016. We critically reviewed all studies based on the PICOS criteria. QUADAS-2 was used to evaluate the quality of the methodology of the included studies. Results This meta-analysis included 17 studies (629 patients, average age [mean ± SD] = 42.7 ± 6.3 years). The pooled sensitivity and specificity of 18F-FDG and 68Ga peptides were 0.85 (95% confidence interval [CI] = 0.78–0.91) and 0.55 (95% CI = 0.37–0.73), and 0.95 (95% CI = 0.92–0.97) and 0.87 (95% CI = 0.63–0.96), respectively. The area under the sROC curves of the 18F-FDG and 68Ga peptides were 0.88 (95% CI = 0.85–0.91) and 0.78 (95% CI = 0.74–0.81), respectively. A subgroup analysis demonstrated that the difference at the per-lesion level and gene mutation level was significant. Conclusion Compared to 18F-FDG PET/CT, the 68Ga-somatostatin receptor demonstrated good performance in the localization of metastatic PCs/PGLs, especially those with germline mutations. The use of the 68Ga-somatostatin receptor can be a new tool in the diagnosis of metastatic PCs/PGLs.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Jelena Saponjski ◽  
Djuro Macut ◽  
Dragana Sobic Saranovic ◽  
Branislava Radovic ◽  
Vera Artiko

AbstractBackgroundThe aim of the study was evaluation of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography with computed tomography (PET/CT) in the detection of active disease in the patients with suspected recurrence of the medullary thyroid carcinoma (MTC).Patients and methods18F-FDG PET/CT investigation was performed in 67 patients, investigated from 2010 to 2019. _ Follow up was performed from 6 to 116 months after surgery (median 16.5 months, x± SD = 29±28.9 months). Twenty five of 67 patients underwent 99mTc-dimercaptosuccinic acid (99mTc-DMSA) scintigraphy, 11 underwent somatostatin receptor scintigraphy (SRS) with 99mTc-HYNIC TOC while 11 123I-metaiodobenzylguanidine (MIBG) scintigraphy.ResultsFrom 67 patients, 35 (52.2%) had true positive 18F-FDG PET/CT findings (TP). Average maximal standardized uptake value (SUVmax) for all TP lesions was 5.01+3.6. In 25 (37.3%) patients findings were true negative (TN). Four (6%) patients had false positive (FP) findings while three (4.5%) were false negative (FN). Thus, sensitivity of the 18F-FDG PET/ CT was 92.11%, specificity 86.21%, positive predictive value 89.74%, negative predictive value 89.29% and accuracy 89.55%. In 27 patients (40%) 18F-FDG PET/CT finding influenced further management of the patient.Conclusions18F-FDG PET/CT has high accuracy in the detection of metastases/recurrences of MTC in patients after thyroidectomy as well as in evaluation and the appropriate choice of the therapy.


Diagnostics ◽  
2019 ◽  
Vol 10 (1) ◽  
pp. 2
Author(s):  
Marie Meyer ◽  
Marie Nicod Lalonde ◽  
Nathalie Testart ◽  
Mario Jreige ◽  
Christel Kamani ◽  
...  

Background: Tumor-induced or oncogenic osteomalacia (TIO) is a rare paraneoplastic syndrome in which osteomalacia is a consequence of fibroblast growth factor 23 (FGF23) secretion by a mesenchymal tumor. The localization of the culprit lesion in patients with TIO is often challenging. Several studies have evaluated the detection rate (DR) of these tumors using somatostatin receptor positron emission tomography (SSTR-PET/CT). We aimed to summarize literature findings on this topic providing pooled estimates of DR. Methods: A comprehensive literature search by screening PubMed, Embase and Cochrane library electronic databases through August 2019 was performed. The pooled DR of culprit tumors using SSTR-PET/CT in patients with TIO was calculated using a random-effects statistical model. Results: Fourteen studies on the use of SSTR-PET/CT in detecting the culprit tumor in patients with TIO were included in the qualitative analysis. The pooled DR of SSTR-PET/CT on a per-patient-based analysis calculated using eleven studies (166 patients) was 87.6% (95% confidence interval (95% CI) 80.2–95.1%). Statistical heterogeneity among studies was detected (I-square = 63%), likely due to the use of different radiolabeled somatostatin analogues, as demonstrated by a subgroup analysis. Conclusions: Despite limited literature data due to the rarity of the disease, SSTR-PET/CT demonstrated a very high DR of culprit tumors in patients with TIO and it could be used as first-line imaging method for this indication.


2014 ◽  
Vol 2014 ◽  
pp. 1-13 ◽  
Author(s):  
Salvatore Annunziata ◽  
Carmelo Caldarella ◽  
Daniele Antonio Pizzuto ◽  
Federica Galiandro ◽  
Ramin Sadeghi ◽  
...  

Objective.To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) or PET/computed tomography (PET/CT) for primary tumor evaluation in patients with cholangiocarcinoma (CCa).Methods.A comprehensive literature search of studies published through December 31, 2013, was performed. Pooled sensitivity and specificity were calculated on a per patient based analysis. Subgroup analyses considering the device used (PET versus PET/CT) and the localization of the primary tumor (intrahepatic cholangiocarcinoma (IH-CCa), extrahepatic cholangiocarcinoma (EH-CCa), and hilar cholangiocarcinoma (H-CCa)) were carried out.Results.Twenty-three studies including 1232 patients were included in the meta-analysis. Pooled sensitivity and specificity of18F-FDG-PET or PET/CT were 81% and 82%, respectively. Pooled sensitivity and specificity, respectively, were 80% and 89% for PET, 82% and 75% for PET/CT, 95% and 83% for IH-CCa, 84% and 95% for H-CCa, and 76% and 74% for EH-CCa.Conclusions.  18F-FDG-PET and PET/CT were demonstrated to be accurate diagnostic imaging methods for primary tumor evaluation in patients with CCa. These tools have a better diagnostic accuracy in patients with IH-CCa than in patients with EH-CCa. Further studies are needed to evaluate the accuracy of18F-FDG-PET or PET/CT in patients with H-CCa.


2019 ◽  
Vol 26 (4) ◽  
Author(s):  
C. Harlos ◽  
U. Metser ◽  
R. Poon ◽  
P. MacCrostie ◽  
W. Mason

Objective Paraneoplastic neurologic syndrome (pns) is a rare condition indirectly caused by an underlying malignancy. In many cases, the malignancy is occult at the time of the pns diagnosis, and the optimal diagnostic modality to detect the underlying tumour is unclear. In the present study, we aimed to assess the utility of 18F-fluorodeoxyglucose positron-emission tomography (fdg-pet) or pet integrated with computed tomography (pet/ct) in the investigation of these patients.Methods We retrospectively analyzed data from the PET Access Program (pap) database in the province of Ontario to identify patients who underwent fdg-pet/ct imaging as part of a workup for pns. In all patients, prior conventional imaging was negative or indeterminate. To determine the diagnostic accuracy of fdg-pet/ct, data about demographics, presenting symptoms, and biochemical and radiologic workup, including fdg-pet/ct imaging results, were compared with data collected by the Ontario Cancer Registry (ocr). A systematic review of the literature and meta-analysis using our study inclusion criteria were performed for studies of fdg-pet accuracy.Results Of 29 patients identified in the pap database, 9 had fdg-pet/ct results suspicious for malignancy. When correlated with data from the ocr, 5 fdg-pet/ct results were informative, resulting in a detection rate of 17%. Local sensitivity and specificity were 0.83 and 0.83 respectively. Two studies meeting our criteria were identified in the literature. The pooled sensitivity and specificity from the literature and local data were 0.88 and 0.90 respectively.Conclusions When investigating for underlying malignancy in patients with suspected pns and negative conventional imaging, pet has high sensitivity and specificity.


Sign in / Sign up

Export Citation Format

Share Document