scholarly journals Deep Learning Versus Iterative Reconstruction for CT Pulmonary Angiography in the Emergency Setting: Improved Image Quality and Reduced Radiation Dose

Diagnostics ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 558
Author(s):  
Marc Lenfant ◽  
Olivier Chevallier ◽  
Pierre-Olivier Comby ◽  
Grégory Secco ◽  
Karim Haioun ◽  
...  

To compare image quality and the radiation dose of computed tomography pulmonary angiography (CTPA) subjected to the first deep learning-based image reconstruction (DLR) (50%) algorithm, with images subjected to the hybrid-iterative reconstruction (IR) technique (50%). One hundred forty patients who underwent CTPA for suspected pulmonary embolism (PE) between 2018 and 2019 were retrospectively reviewed. Image quality was assessed quantitatively (image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) and qualitatively (on a 5-point scale). Radiation dose parameters (CT dose index, CTDIvol; and dose-length product, DLP) were also recorded. Ninety-three patients were finally analyzed, 48 with hybrid-IR and 45 with DLR images. The image noise was significantly lower and the SNR (24.4 ± 5.9 vs. 20.7 ± 6.1) and CNR (21.8 ± 5.8 vs. 18.6 ± 6.0) were significantly higher on DLR than hybrid-IR images (p < 0.01). DLR images received a significantly higher score than hybrid-IR images for image quality, with both soft (4.4 ± 0.7 vs. 3.8 ± 0.8) and lung (4.1 ± 0.7 vs. 3.6 ± 0.9) filters (p < 0.01). No difference in diagnostic confidence level for PE between both techniques was found. CTDIvol (4.8 ± 1.4 vs. 4.0 ± 1.2 mGy) and DLP (157.9 ± 44.9 vs. 130.8 ± 41.2 mGy∙cm) were lower on DLR than hybrid-IR images. DLR both significantly improved the image quality and reduced the radiation dose of CTPA examinations as compared to the hybrid-IR technique.

2019 ◽  
Author(s):  
Jihang Sun ◽  
Lixin Yang ◽  
Zuofu Zhou ◽  
Dan Zhang ◽  
Wei Han ◽  
...  

Abstract Background The adverse effect of low-dose CT on image quality may be mitigated using iterative reconstructions. The purpose of this study was to evaluate the performance of the full model-based iterative reconstruction (MBIR) and adaptive statistical reconstruction (ASIR) algorithms in low radiation dose and low contrast dose abdominal contrast-enhanced CT (CECT) in children. Methods A total of 59 children (32 males and 27 females) undergoing low radiation dose (100kVp) and low contrast dose (270 mgI/ml) abdominal CECT were enrolled. The median age was 4.0 years (ranging from 0.3 to 13 years). The raw data were reconstructed with MBIR, ASIR and filtered back projection (FBP) algorithms into 6 groups (MBIR, 100%ASIR, 80%ASIR, 60%ASIR, 40%ASIR and FBP). The CT numbers, standard deviations, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of liver, pancreas, kidney and abdominal aorta were measured. Two radiologists independently evaluated the subjective image quality including the overall image noise and structure display ability on a 4-point scale with 3 being clinically acceptable. The measurements among the reconstruction groups were compared using one-way ANOVA. Results The overall image noise score and display ability were 4.00±0.00 and 4.00±0.00 with MBIR, and 3.27±0.33 and 3.25±0.43 with ASIR100%, respectively, which met the diagnostic requirement; other reconstructions couldn’t meet the diagnostic requirements. Compared with FBP images, the noise of MBIR images was reduced by 62.86%-65.73% for the respective organs (F=48.15-80.47, P<0.05), and CNR increased by 151.38%-170.69% (F=22.94-38.02, P<0.05). Conclusions MBIR or ASIR100% improves the image quality of low radiation dose and contrast dose abdominal CT in children to meet the diagnostic requirements, and MBIR has the best performance.


2021 ◽  
Vol 94 (1117) ◽  
pp. 20200677
Author(s):  
Andrea Steuwe ◽  
Marie Weber ◽  
Oliver Thomas Bethge ◽  
Christin Rademacher ◽  
Matthias Boschheidgen ◽  
...  

Objectives: Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. Methods: In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. Results: On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. Conclusion: The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. Advances in knowledge: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information. The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.


2017 ◽  
Vol 59 (5) ◽  
pp. 553-559 ◽  
Author(s):  
Yun Hye Ju ◽  
Geewon Lee ◽  
Ji Won Lee ◽  
Seung Baek Hong ◽  
Young Ju Suh ◽  
...  

Background Reducing radiation dose inevitably increases image noise, and thus, it is important in low-dose computed tomography (CT) to maintain image quality and lesion detection performance. Purpose To assess image quality and lesion conspicuity of ultra-low-dose CT with model-based iterative reconstruction (MBIR) and to determine a suitable protocol for lung screening CT. Material and Methods A total of 120 heavy smokers underwent lung screening CT and were randomly and equally assigned to one of five groups: group 1 = 120 kVp, 25 mAs, with FBP reconstruction; group 2 = 120 kVp, 10 mAs, with MBIR; group 3 = 100 kVp, 15 mAs, with MBIR; group 4 = 100 kVp, 10 mAs, with MBIR; and group 5 = 100 kVp, 5 mAs, with MBIR. Two radiologists evaluated intergroup differences with respect to radiation dose, image noise, image quality, and lesion conspicuity using the Kruskal–Wallis test and the Chi-square test. Results Effective doses were 61–87% lower in groups 2–5 than in group 1. Image noises in groups 1 and 5 were significantly higher than in the other groups ( P < 0.001). Overall image quality was best in group 1, but diagnostic acceptability of overall image qualities in groups 1–3 was not significantly different (all P values > 0.05). Lesion conspicuities were similar in groups 1–4, but were significantly poorer in group 5. Conclusion Lung screening CT with MBIR obtained at 100 kVp and 15 mAs enables a ∼60% reduction in radiation dose versus low-dose CT, while maintaining image quality and lesion conspicuity.


2018 ◽  
Vol 60 (2) ◽  
pp. 177-185
Author(s):  
Xiangying Du ◽  
Bin Lu ◽  
Daoyu Hu ◽  
Bin Song ◽  
Kuncheng Li

Background Concern about radiation exposure is leading to an increasing interest in low-concentration contrast medium administration. Purpose To evaluate the image quality and safety profile after administration of iodixanol 270 mg I/mL at 100-kVp tube voltage with iterative reconstruction in subjects undergoing computed tomography angiography (CTA). Material and Methods Patients who completed CTA examination using iodixanol 270 mg I/mL and 100-kVp tube voltage along with iterative reconstruction for coronary, aortic, head and neck, renal, or pulmonary arteries were included. Image quality was qualitatively and quantitatively evaluated. Incidence of adverse events (AEs) and adverse drug reactions (ADRs) within seven days and radiation dose were also analyzed. Results A total of 4513 individuals in 42 centers in China were enrolled, among which 4367 were included in efficacy analysis. The mean image quality score was 4.8 ± 0.45 across all arteries (all above 4.6) and 99.7% of the individuals’ images were classified as evaluable. The CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the regions of interest (ROIs) were 431.79 ± 99.018, 18.29 ± 11.947, and 28.21 ± 19.535 HU, respectively. Of all the participants, 68 (1.5%) and 65 (1.4%) experienced AEs and ADRs, respectively. No serious AEs or AEs leading to discontinuation occurred. The average effective radiation dose was 3.13 ± 2.550 mSv. Conclusion Iodixanol 270 mg I/mL in combination with 100-kVp tube voltage and iterative reconstruction could be safely applied in CTA and yield high-quality and evaluable images with reduced radiation dose.


Author(s):  
A. Mokhtar ◽  
Z. A. Aabdelbary ◽  
A. Sarhan ◽  
H. M. Gad ◽  
M. T. Ahmed

Abstract Background To study radiation dose, image quality and low-contrast cylinder detectability from multislice CT (MSCT) abdomen by using low tube voltage using the American College of Radiology (ACR) phantom. The ACR phantom (low-contrast module) was scanned with 64 MSCT scanner (Brilliance, Philips Medical System, Eindhoven, Netherlands) with 80 and 120 KVP, utilizing different tube current time product (mAs) range from 50 to 380 mAs. The image noise (SD), signal to noise ratio, contrast-to-noise ratio (CNR), and scores of low contrast detectability were assessed for every image respectively. Results From images analyses, the noise essentially increased with the use of low tube voltage. The CNR was 0.94 ± 0.27 at 120 KVP, and CNR was 0.43 ± 0.22 at 80 KVP. However, with the same dose, there were no differences of statistical significance in scores of low-contrast detectability between 120 KVP at 300mAs and 80 KVP at (200–380) mAs (p > 0.05). At 300 mAs, the CTDIvol obtained at 80 KVP was about 29% of that at 120 KVP. The CTDIvol obtained at 80 KVP were decreased from 5% at 50 mAs, to 37% at 380 mAs. Conclusions There is a possibility to decrease exposure of radiation virtually by reducing KVP from 120 to 80 KVP in examination of abdominal CT when the high tube current is used, though increasing image noise at low tube voltage.


2020 ◽  
Vol 28 (5) ◽  
pp. 893-903
Author(s):  
H.H. Harun ◽  
M.K.A. Karim ◽  
Z. Abbas ◽  
A. Sabarudin ◽  
S.C. Muniandy ◽  
...  

PURPOSE: To evaluate the influence of iterative reconstruction (IR) levels on Computed Tomography (CT) image quality and to establish Figure of Merit (FOM) value for CT Pulmonary Angiography (CTPA) examinations. METHODS: Images of 31 adult patients who underwent CTPA examinations in our institution from March to April 2019 were retrospectively collected. Other data, such as scanning parameters, radiation dose and body habitus information from the subjects were also recorded. Six different levels of IR were applied to the volume data of the subjects. Five circles of the region of interest (ROI) were drawn in five different arteries namely, pulmonary trunk, right pulmonary artery, left pulmonary artery, ascending aorta and descending aorta. The mean Signal-to-noise ratio (SNR) was obtained, and the FOM was calculated in a fraction of the SNR2 divided by volume-weighted CT dose index (CTDIvol) and SNR2 divided by the size-specific dose estimates (SSDE). RESULTS: Overall, we observed that the mean value of CTDIvol and SSDE were 13.79±7.72 mGy and 17.25±8.92 mGy, respectively. Notably, SNR values significantly increase with increase of the IR level (p < 0.05). There are also significant differences (p < 0.05) in the FOM for both SNR2/SSDE and SNR2/CTDIvol attained in different IR levels. CONCLUSION: We successfully evaluate the value of radiation dose and image quality performance and set up a figure of merit for both parameters to further verify scanning protocols by radiology personnel.


Author(s):  
Chao Tian ◽  
Tian-hao Yang ◽  
Le-jun Fu ◽  
Song Jin

IntroductionObjective: This study aims to investigate the reduction of radiation dose in cerebral CT perfusion by lower low-tube current.Material and methodsTwo hundred patients, who underwent cerebral non-contrast computed tomography (CT) and CT perfusion, were randomized into four groups according to tube current and contrast media (CM) concentration: group A (60 mAs, 320 mgI/ml), group B (60 mAs, 370 mgI/ml), group C (100 mAs, 320 mgI/ml), and group D (100 mAs, 370 mgI/ml). Among these four groups, the CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED) was calculated. The quantitative image comparison included maximum enhancement, noise, signal-to-noise ratio (SNR), cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) from five regions of interests (ROIs).ResultsRanging from 100 mAs to 60 mAs, groups A and B achieved 40% lower CTDIvol, DLP and ED, when compared with groups C and D. Both the maximum enhancement and noise of all ROIs were higher in groups A and B, when compared to groups C and D (P<0.05). The CBV values were higher in groups B and D, when compared to groups A and C (P<0.05). The image quality (IQ) of each group of perfusion maps met the requirements for imaging diagnosis.ConclusionsThe reduction in tube current from 100 mAs to 60 mAs for cerebral CT perfusion led to a 40% reduction in radiation dose without sacrificing image quality.


2021 ◽  
Author(s):  
Xiao-ying Zhao ◽  
Lu-lu Li ◽  
Jian Song ◽  
Jing Chen ◽  
Ji Xu ◽  
...  

To investigate the optimal pre- and post-adaptive statistical iterative reconstruction-V (ASiR-V) levels in pediatric abdominal computed tomography (CT) to minimize radiation exposure and maintain image quality using an animal model. A total of 10 standard piglets were selected and scanned to obtain unenhanced and enhanced images under different pre-ASiR-V conditions. The corresponding images were obtained using ASiR-V algorithm at different post-ASiR-V levels. CT value, signal-to-noise ratio (SNR), contrast noise ratio (CNR) of abdominal tissues, subjective image score, and radiation dose of unenhanced and enhanced scans were analyzed. With the increase of pre-ASiR-V level, the radiation dose in piglets gradually decreased (P &lt; 0.05). Within the same group of pre-ASiR-V, the image noise was decreased (P &lt; 0.05) by increasing post-ASiR-V level. There was no statistical difference between SNR and CNR values. In unenhanced CT, the subjective score of the images with the combination of 40% pre- and 60% post-ASiR-V levels had no statistical difference compared to the combination of 0% pre- and 60% post-ASiR-V levels, while the radiation dose decreased by 31.6%. In the enhanced CT, the subjective image score with the 60% pre- and 60% post-ASiR-V combination had no statistical difference compared to the 0% pre- and 60% post-ASiR-V combination, while the radiation dose was reduced by 48.9%. The combined use of pre- and post-ASiR-V maintains image quality at the reduced radiation dose. The optimal level for unenhanced CT is 40% pre-combined with 60% post-ASiR-V, while that for enhanced CT is 60% pre- combined with 60% post-ASiR-V in pediatric abdominal CT.


2014 ◽  
Vol 83 (10) ◽  
pp. 1962-1969 ◽  
Author(s):  
Azien Laqmani ◽  
Marc Regier ◽  
Simon Veldhoen ◽  
Alexandra Backhaus ◽  
Felicia Wassenberg ◽  
...  