scholarly journals Clinical Feasibility of Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging with Computed Diffusion-Weighted Imaging Technique in Breast Cancer Patients

Diagnostics ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 538
Author(s):  
Eun Cho ◽  
Jin Hwa Lee ◽  
Hye Jin Baek ◽  
Ji Young Ha ◽  
Kyeong Hwa Ryu ◽  
...  

Background: We evaluated the feasibility of the reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) with computed DWI technique by comparison and analysis of the inter-method agreement among acquired rFOV DWI (rFOVA), rFOV DWI with computed DWI technique (rFOVS), and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in patients with breast cancer. Methods: A total of 130 patients with biopsy-proven breast cancers who underwent breast MRI from April 2017 to December 2017 were included in this study. The rFOVS were reformatted by calculation of the apparent diffusion coefficient curve obtained from rFOVA b = 0 s/mm2 and b = 500 s/mm2. Visual assessment of the image quality of rFOVA b = 1000 s/mm2, rFOVS, and DCE MRI was performed using a four-point grading system. Morphologic analyses of the index cancer was performed on rFOVA, rFOVS, and DCE MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast of tumor-to-parenchyma (TPC) were calculated. Results: Image quality scores with rFOVA, rFOVS, and DCE MRI were not significantly different (p = 0.357). Lesion analysis of shape, margin, and size of the index cancer also did not show significant differences among the three sequences (p = 0.858, p = 0.242, and p = 0.858, respectively). SNR, CNR, and TPC of DCE MRI were significantly higher than those of rFOVA and rFOVS (p < 0.001, p = 0.001, and p = 0.016, respectively). Significant differences were not found between the SNR, CNR, and TPC of rFOVA and those of rFOVS (p > 0.999, p > 0.999, and p > 0.999, respectively). Conclusion: The rFOVA and rFOVS showed nearly equivalent levels of image quality required for morphological analysis of the tumors and for lesion conspicuity compared with DCE MRI.

2018 ◽  
Vol 22 (2) ◽  
Author(s):  
Dibuseng P. Ramaema ◽  
Richard J. Hift

Background: The use of multi-parametric magnetic resonance imaging (MRI) in the evaluation of breast tuberculosis (BTB).Objectives: To evaluate the value of diffusion-weighted imaging (DWI), T2-weighted (T2W) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in differentiating breast cancer (BCA) from BTB.Method: We retrospectively studied images of 17 patients with BCA who had undergone preoperative MRI and 6 patients with pathologically proven BTB who underwent DCE-MRI during January 2014 to January 2015.Results: All patients were female, with the age range of BTB patients being 23–43 years and the BCA patients being 31–74 years. Breast cancer patients had a statistically significant lower mean apparent diffusion coefficient (ADC) value (1072.10 +/- 365.14), compared to the BTB group (1690.77 +/- 624.05, p = 0.006). The mean T2-weighted signal intensity (T2SI) was lower for the BCA group (521.56 +/- 233.73) than the BTB group (787.74 +/- 196.04, p = 0.020). An ADC mean cut-off value of 1558.79 yielded 66% sensitivity and 94% specificity, whilst the T2SI cut-off value of 790.20 yielded 83% sensitivity and 83% specificity for differentiating between BTB and BCA. The homogeneous internal enhancement for focal mass was seen in BCA patients only.Conclusion: Multi-parametric MRI incorporating the DWI, T2W and DCE-MRI may be a useful tool to differentiate BCA from BTB.


Sign in / Sign up

Export Citation Format

Share Document