scholarly journals CO2 Capture in A Bubble-Column Scrubber Using MEA/CaCl2/H2O Solution—Absorption and Precipitation

Crystals ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 694
Author(s):  
Pao Chi Chen ◽  
Shiun Huang Zhuo

This study used the solvent monoethylamine (MEA)/CaCl2/H2O to investigate CO2 absorption and CaCO3 crystallization in a bubble column scrubber. The variables explored were pH, gas flow rate, gas concentration, the liquid flow rate of the solution to absorb CO2, and CaCO3 crystallization. Under a continuous mode, the solution of CaCl2 was fed continuously, and the pH dropped after CO2 absorption. To maintain the set pH value, there was an automatic input of the MEA solvent into the bubble column. In addition to maintaining the pH, the solution could also absorb CO2 and produce CaCO3 crystals, which served two purposes. The results showed that there were mainly vaterite crystals. At different pH values, the lower the pH, the higher the precipitation rate of vaterite (Fp), and vice versa. However, under different gas flow rates, the Fp decreased as the pH value increased. Additionally, the process variables also affected the absorption rate (RA) and the overall mass-transfer coefficient (KGa) generally increased with increasing pH, gas concentration, and gas flow rate. However, it slowed down under operating conditions at high pH and high gas flow rate. Finally, correlation equations for RA, KGa, and Fp were also obtained and discussed in the study.

2016 ◽  
Vol 859 ◽  
pp. 153-157
Author(s):  
Pao Chi Chen ◽  
Sheng Zhong Lin

This work uses a continuous bubble-column scrubber for the absorption of CO2 with a 5M MEA solution under a constant pH environment to explore the effect of the pH of the solution and gas-flow rate (Qg) on the removal efficiency (E), absorption rate (RA), overall mass-transfer coefficient (KGa), liquid flow rate (QL), gas-liquid flow ratio (γ), and scrubbing factors (φ). From the outlet CO2 concentration with a two-film model, E, RA, KGa, QL, γ, and φ can be simultaneously determined at the steady state. Depending on the operating conditions, the results show that E (80-97%), RA(2.91x10-4-10.0x10-4mol/s-L), KGa (0.09-0.48 1/s), QL(8.74-230.8mL/min), γ (0.19-5.39), and φ (0.031-0.74 mol/mol-L) are found to be comparable with other solvents. In addition, RA, KGa, E, and QL have been used to correlate with pH and Qg, respectively, with the results further explained.


2012 ◽  
Vol 573-574 ◽  
pp. 538-541
Author(s):  
Yan Ping Duan ◽  
Sven Geissen ◽  
Ling Chen

Ozonation of clofibric acid (CA) in aqueous solution was carried out under continuous operation in a cascade bubble column. The influence of operation parameters including initial CA concentration, gas flow rate, liquid flow rate and pH on the removal of CA and TOC was investigated. The results indicated that ozonation could be used to effectively remove CA from water. Increasing the initial CA concentration resulted in a decrease of the CA and TOC removal efficiency. A comparison of CA removal efficiency and ozone utilization between cascade and conventional bubble column indicated that cascade bubble column was an effective way for increasing the solubility ozone in the reactor.


REAKTOR ◽  
2019 ◽  
Vol 18 (04) ◽  
pp. 177 ◽  
Author(s):  
Aji Prasetyaningrum ◽  
Dyah Arum Kusumaningtyas ◽  
Purbo Suseno ◽  
Ratnawati Ratnawati

This research was conducted to calculate the mass transfer coefficient value for ozonation reaction of κ-carrageenan solution in the bubble column reactor. Ozone gas was produced using ozone generator type corona discharge. In this study, operating conditions were regulated at ozone gas flow rate 2- 5 L min-1, pH 4-10, and temperature 29 ± 1 oC. Samples were tested every 5 minutes to determine the dissolved ozone concentration. The results showed that dissolved ozone concentrations increased with increasing ozonation time and ozone gas flow rate. However, a very high gas flow rate can increase turbulence so that the mass transfer coefficient (kLa) value decreased. In alkaline conditions, the formation of free radicals (HO*) increases so that the amount of dissolved ozone decreases. The kLa value of ozone gas in κ-carrageenan solution is slightly lower than the kLa value of the ozone gas in the water. The results of this study indicate that (kLa) ozone gas in water is 0.131 / minute while the value (kLa) in κ-carrageenan solution is 0.128 / minute.


Konversi ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 6
Author(s):  
Erlinda Ningsih ◽  
Abas Sato ◽  
Mochammad Alfan Nafiuddin ◽  
Wisnu Setyo Putranto

Abstract- One of the most widely used processes for CO2 gas removal is Absorption. Carbon dioxide is the result of the fuel combustion process which of the hazardous gases. The aim of this research is to determine the total mass transfer coefficient and analyze the effect of the absorbent flow rate of the absorbent solution with the promoter and the gas flow rate to the total mass transfer coefficient value. The variables consisted of liquid flow rate: 1, 2, 3, 4, 5 liter/min, gas flow rate: 15, 25, 30, 40, 50 liter/min and MSG concentration: 0%, 1%, 3% and 5% by weight. The solution of Pottasium Carbonate as absorbent with MSG promoter is flowed through top column and CO2 gas flowed from bottom packed column. Liquids were analyzed by titration and the gas output was analyzed by GC. From this research, it is found that the flow rate of gas and the liquid flow rate is directly proportional to the value of KGa. The liquid flow rate variable 5 liters / minute, gas flow rate 15 l / min obtained value of KGa 11,1102 at concentration of MSG 5%. Keywords:  Absorption, CO2,  K2CO3, MSG. 


1994 ◽  
Vol 29 (10-11) ◽  
pp. 231-241 ◽  
Author(s):  
H. T. Chang ◽  
B. E. Rittmann

This paper presents a unified model that inter-relates gas flow rate, liquid flow rate, and hold-ups of each of the liquid, gas, and solid phases in three-phase, fluidized-bed biofilm (TPFBB) process. It describes how carrier properties, biofilm properties, and gas and liquid flow velocities control the system dynamics, which ultimately will affect the density, thickness, and distribution of the biofilm. The paper describes the development of the mathematical model to correlate the effects of gas flow rate, liquid flow rate, solid concentration, and biofilm thickness and density. This knowledge is critically needed in light of the use of TPFBB processes in treating industrial wastewater, which often has high substrate concentration. For example, the proper design of the TPFBB process requires mathematical description of the cause-effect relationship between biofilm growth and fluidization.


1989 ◽  
Vol 8 (2) ◽  
pp. 63-68
Author(s):  
A. J. Rautenbach ◽  
G. Kornelius

Spray columns are widely used in industry as a gas-liquid contacting apparatus because of the advantages of a high transfer area per unit volume and the tow gas side resistance. For a large number of systems, mass transfer parameters are not available and an experimental determination for the system benzene/wash oil was therefore carried out. The experimental technique and design are described. The variation in mass transfer coefficient as function of gas flow rate, liquid flow rate and column height agrees with those published elsewhere.


Nowadays, CO2 as the product of fossil fuel combustions, is polluting the air and the human environment, and it causes global warming. To reduce the negative effect of CO2 presence, it should be removed from the air by capturing methods. Hollow fiber membrane contactor (HFMC) system is one of the most efficient method for CO2 capturing than the other feasible capturing methods. In the present paper an HFMC absorbing system has been simulated using COMSOL Multiphysics software and the effect of flow rates of gas and liquid on the amount of CO2 removal has been studied. Aqueous solution of Mono-ethanolamine (MEA) is entered as the absorbent liquid in the tubes, and CO2 is removed from the shell side by the diffusion phenomena by participating in the chemical reaction with MEA. The results show that the higher liquid flow rate the higher %CO2 removal from the inserted gas. Against this result, the percentage of CO2 removal decreases with increasing the gas flow rate as expected. Higher gas flow rate leads the gas velocity to higher values and less possibility of absorbing by the diffusion method. The rate of the CO2 removal variation with liquid flow rate is higher than the CO2 removal variation whit the gas flow rate.


2021 ◽  
Vol 11 (22) ◽  
pp. 10708
Author(s):  
Adel Almoslh ◽  
Falah Alobaid ◽  
Christian Heinze ◽  
Bernd Epple

An experimental study was conducted in the sieve tray column to investigate the influence of gas flow rate on the hydrodynamic characteristics of the sieve tray, such as total tray pressure drop, wet tray pressure drop, dry tray pressure drop, clear liquid height, liquid holdup, and froth height. The hydrodynamic characteristics of the sieve tray were investigated for the gas/water system at different gas flow rates from 12 to 24 Nm3/h and at different pressures of 0.22, 0.24, and 0.26 MPa. In this study, a simulated waste gas was used that consisted of 30% CO2 and 70% air. The inlet volumetric flow rate of the water was 0.148 m3/h. The temperature of the inlet water was 19.5 °C. The results showed that the gas flow rate has a significant effect on the hydrodynamic characteristics of the tray. The authors investigated the effect of changing these hydrodynamic characteristics on the performance of a tray column used for CO2 capture.


2020 ◽  
pp. 44-50
Author(s):  
O. E. Seredyuk ◽  
N. M. Malisevich

The article is devoted to the study of the influence of the qualitative and quantitative composition of gas environments on the flame temperature of the combusted gas at different values of gas flow rate and changes volume ratio gas-air in its combustion. The functional scheme of the developed labo­ratory stand (Fig. 1), which provides temperature measurement during combustion of natural gas or propane-butane mixture, is considered. The design of the developed burner is described and the expe­rimental researches are carried out when measuring the flame temperature of the combusted gas during the operation of the laboratory stand. The opera­ting conditions of different thermocouples in measuring the temperature of the flared gas are investigated (Fig. 2). The temperature instability in the lower and upper flames was experimentally determined (Fig. 3) and its difference from the reference data [12, 13]. The measurement of the flame temperature with a uncased thermocouple and two thermocouples of different types with protective housings is reali­zed. Methodical error of temperature measurement by different thermocouples was estimated (Fig. 5). An algorithm for the implementation of measurement control in determining the heat of combustion of natural gas according to the patented method is outlined [11]. Experimental studies of temperature changes of combusted gas mixtures at different gas flow rates and different ratios with air, which is additionally supplied for gas combustion, were carried out (Figs. 4, 7). The computer simulation (Figs. 6, 8) of the change in the flame temperature was performed on the basis of the experimental data, which allowed to obtain approximate equations of the functional dependence of the flame temperature on the gas flow rate and the ratio of the additional air and gas consumption. The possibility of realization of the device of express control of the heating value of natural gas by measuring the combustion temperature of the investigated gases, which is based on the expe­rimentally confirmed increase in the flame temperature of the investigated gases with increasing their calorific value, is substantiated (Fig. 9). The necessity of further investigation of the optimization design characteristics of the burner and the operating conditions of combustion of the gases under rapid cont­rol of their combustion heat was established (Fig. 9).


2019 ◽  
Vol 2019 ◽  
pp. 1-19 ◽  
Author(s):  
Fabio Zaza ◽  
Vanessa Pallozzi ◽  
Emanuele Serra

Environmental degradation and resource depletion drive scientific research priorities to develop technologies for sustainable productive systems. Among them, chemical sensing technology plays a key role for regulating energetic, ecological, and productive efficiency by monitoring and controlling the industrial processes. Semiconducting metal oxide sensors are particularly attractive technology because of their simplicity in function, small size, and projected low cost. The aim of this work is to synthesize Ti-substituted lanthanum ferrite perovskite, LaFe0.8Ti0.2O3, in order to develop a resistive sensor device for monitoring carbon monoxide. Since sensor performances are affected by experimental factors, such as temperature, target gas concentration, and gas flow rate, the aim of the authors was to define the optimum working condition by performing multiple regression analyses. The investigated ranges of operating conditions were temperature from 300 to 480°C, carbon monoxide concentration from 100 to 200 ppm, and inlet-gas flow rate from 40 to 100 cm3/min. The results confirm that the applied systematic analysis is a powerful method for studying the direct and indirect effects of every experimental factor on sensor performance and for computing mathematical models with predictive ability, that are useful tools for defining the optimum chemiresistors’ operating conditions. In addition, mathematical models are able to be used as multiple-factor surface calibration for restive gas sensor devices.


Sign in / Sign up

Export Citation Format

Share Document