scholarly journals Extubation Readiness in Preterm Infants: Evaluating the Role of Monitoring Intermittent Hypoxemia

Children ◽  
2021 ◽  
Vol 8 (3) ◽  
pp. 237
Author(s):  
Elie G. Abu Jawdeh ◽  
Amrita Pant ◽  
Aayush Gabrani ◽  
M. Douglas Cunningham ◽  
Thomas M. Raffay ◽  
...  

Preterm infants with respiratory distress may require mechanical ventilation which is associated with increased pulmonary morbidities. Prompt and successful extubation to noninvasive support is a pressing goal. In this communication, we show original data that increased recurring intermittent hypoxemia (IH, oxygen saturation <80%) may be associated with extubation failure at 72 h in a cohort of neonates <30 weeks gestational age. Current-generation bedside high-resolution pulse oximeters provide saturation profiles that may be of use in identifying extubation readiness and failure. A larger prospective study that utilizes intermittent hypoxemia as an adjunct predictor for extubation readiness is warranted.

2017 ◽  
Vol 2017 ◽  
pp. 1-2
Author(s):  
Pragya Punj ◽  
Premkumar Nattanmai ◽  
Pravin George ◽  
Christopher R. Newey

Postextubation stridor is associated with significant morbidity. It commonly results in extubation failure after established medical treatment fails, such as nebulized epinephrine and/or intravenous steroids. The role of heliox (i.e., combination of helium and oxygen) in managing patients with postextubation stridor has not been fully established. We report two cases of postextubation stridor successfully treated with heliox delivered with bilevel positive airway pressure (BiPAP) after failure of standard medical therapy.


2020 ◽  
Vol 9 (3) ◽  
pp. 638 ◽  
Author(s):  
Seongji Woo ◽  
So-Yeong Park ◽  
Youngmi Kim ◽  
Jin Pyeong Jeon ◽  
Jae Jun Lee ◽  
...  

Bacterial pneumonia is a major cause of mechanical ventilation in intensive care units. We hypothesized that the presence of particular microbiota in endotracheal tube aspirates during the course of intubation was associated with clinical outcomes such as extubation failure or 28-day mortality. Sixty mechanically ventilated ICU (intensive care unit) patients (41 patients with pneumonia and 19 patients without pneumonia) were included, and tracheal aspirates were obtained on days 1, 3, and 7. Gene sequencing of 16S rRNA was used to measure the composition of the respiratory microbiome. A total of 216 endotracheal aspirates were obtained from 60 patients. A total of 22 patients were successfully extubatedwithin3 weeks, and 12 patients died within 28days. Microbiota profiles differed significantly between the pneumonia group and the non-pneumonia group (Adonis, p < 0.01). While α diversity (Shannon index) significantly decreased between day 1 and day 7 in the successful extubation group, it did not decrease in the failed extubation group among intubated patients with pneumonia. There was a significant difference in the change of βdiversity between the successful extubation group and the failed extubation group for Bray-Curtis distances (p < 0.001). At the genus level, Rothia, Streptococcus, and Prevotella correlated with the change of β diversity. A low relative abundance of Streptococci at the time of intubation was strongly associated with 28-day mortality. The dynamics of respiratory microbiome were associated with clinical outcomes such as extubation failure and mortality. Further large prospective studies are needed to test the predictive value of endotracheal aspirates in intubated patients.


2022 ◽  
Vol 86 (1) ◽  
pp. 398-401
Author(s):  
Mohamed Elsayed Elsetouhi ◽  
Lotfy Mohamed Elsayed ◽  
Ali Abd El-Hameed Abdo ◽  
M. M. Shehab

BMJ Open ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. e045897
Author(s):  
Anna Madeline Kidman ◽  
Brett James Manley ◽  
Rosemarie Anne Boland ◽  
Atul Malhotra ◽  
Susan M Donath ◽  
...  

IntroductionRespiratory distress syndrome is a complication of prematurity and extremely preterm infants born before 28 weeks’ gestation often require endotracheal intubation and mechanical ventilation. In this high-risk population, mechanical ventilation is associated with lung injury and contributes to bronchopulmonary dysplasia. Therefore, clinicians attempt to extubate infants as quickly and use non-invasive respiratory support such as nasal continuous positive airway pressure (CPAP) to facilitate the transition. However, approximately 60% of extremely preterm infants experience ‘extubation failure’ and require reintubation. While CPAP pressures of 5–8 cm H2O are commonly used, the optimal CPAP pressure is unknown, and higher pressures may be beneficial in avoiding extubation failure. Our trial is the Extubation CPAP Level Assessment Trial (ÉCLAT). The aim of this trial is to compare higher CPAP pressures 9–11 cm H2O with a current standard pressures of 6–8 cmH2O on extubation failure in extremely preterm infants.Methods and analysis200 extremely preterm infants will be recruited prior to their first extubation from mechanical ventilation to CPAP. This is a parallel group randomised controlled trial. Infants will be randomised to one of two set CPAP pressures: CPAP 10 cmH2O (intervention) or CPAP 7 cmH2O (control). The primary outcome will be extubation failure (reintubation) within 7 days. Statistical analysis will follow standard methods for randomised trials on an intention to treat basis. For the primary outcome, this will be by intention to treat, adjusted for the prerandomisation strata (GA and centre). We will use the appropriate parametric and non-parametric statistical tests.Ethics and disseminationEthics approval has been granted by the Monash Health Human Research Ethics Committees. Amendments to the trial protocol will be submitted for approval. The findings of this study will be written into a clinical trial report manuscript and disseminated via peer-reviewed journals (on-line or in press) and presented at national and international conferences.Trial registration numberACTRN12618001638224; pre-results.


1995 ◽  
Vol 10 (3) ◽  
pp. 142-144
Author(s):  
Sabena Toor ◽  
Jeff Borenstein ◽  
Zab Mohsenifar

We present a 42-year-old woman with status asthmaticus who required mechanical ventilation and a combination of maneuvers, including barbiturate coma, general anesthesia, high-dose steroids, bronchoscopic pulmonary toilet, and helium-oxygen ventilation, resulting in successful extubation and eventual hospital discharge. This case report illustrates the possible role of combination therapy in the management of severe asthma exacerbation.


Author(s):  
Maria Aparecida Vitagliano Martins ◽  
Silene El-Fakhouri ◽  
Luciene de Oliveira Conterno ◽  
Thie Uehara Sampaio

Introduction: Identification of predictors for successful extubation in an Intensive Care Unity and use of Brain Natriuretic Peptides (BNP) in predicting mechanical ventilation weaning and extubation outcome.Aims: Evaluation of the effect of variables such as patient´s age, severity score, use of sedation, use of vasoactive drugs, hydric balance, blood gas data, days under mechanical ventilation, the occurrence of adverse events and plasma BNP levels on the success of extubation.Method: A prospective cohort study of adult patients admitted to a 12- bed-general ICU, from April 1st 2016 to August 10th 2017, under mechanical ventilation for > 24 h, accompanied until discharge or death. Clinical variables were analyzed and BNP was assessed before initiation of Spontaneous Breathing Trial (SBT) and then again before extubation. Statistical Analysis: a descriptive and comparative data analysis, univariate and logistic regressionanalysis for verification of variables independently related to successful extubation (p < 0.05).Results: Study of 105 patients, mean age of 53.9 ± 19.8 years, 81% of success in extubation; the overall mortality rate of 11.4%; variables associated to successful extubation: age, APACHE II, SAPS II, days of hospitalization before ICU admittance, days under mechanical ventilation, days of stay in ICU and occurrence of nosocomial infection (p < 0.05); BNP levels were lower in patients with successful extubation although not statistically significant;multivariate analysis showed that patient’s age and days of hospitalization before ICU admittance were each independently linked to extubation failure; APACHE II score and days of hospitalization before ICU admittance were each independently associated to risk of death.Conclusion: Despite being older and with higher severity scores, patients had a higher success rate in extubation than found in similar studies. However, the mortality rate in cases of failed extubation was higher. Data obtained was in agreement to studies that suggested that patient´s age, severity score, days of hospitalization before ICU admittance, days of stay in ICU, days under MV and infection occurrence were all variables associated as much extubation failure as to risk of death. A direct association between BNP levels and successful extubation and the usefulness of assessing BNP in the conduction of WMV was not confirmed.


2021 ◽  
Vol 15 (1) ◽  
Author(s):  
Randa Salah Eldin Mohamed ◽  
Abeer Salah Eldin Mohamed ◽  
Waleed Fouad Fathalah ◽  
Mohamed Farouk Mohamed ◽  
Ahmed Aelgharib Ahmed

An amendment to this paper has been published and can be accessed via the original article.


2019 ◽  
Vol 4 (67) ◽  
pp. 180
Author(s):  
Adelina Staicu ◽  
Adela Hanga ◽  
Ioana C. Rotar ◽  
Gabriela C. Zaharie ◽  
Daniel Mureşan

Sign in / Sign up

Export Citation Format

Share Document