scholarly journals Newborn Screening Samples for Diabetes Research: An Underused Resource

Cells ◽  
2020 ◽  
Vol 9 (10) ◽  
pp. 2299
Author(s):  
Jane Frances Grace Lustre Estrella ◽  
Jincy Immanuel ◽  
Veronica Wiley ◽  
David Simmons

Inborn errors of metabolism and diabetes share common derangements in analytes of metabolic networks that are tested for in newborn screening, usually performed 48–72 h after birth. There is limited research examining the metabolic imprint of diabetes on newborn screening results. This paper aims to demonstrate the links between diabetes, biochemical genetics and newborn screening in investigating disease pathophysiology in diabetes, provide possible reasons for the lack of research in diabetes in newborn screening and offer recommendations on potential research areas. We performed a systematic search of the available literature from 1 April 1998 to 31 December 2018 involving newborn screening and diabetes using OVID, MEDLINE, Cochrane and the PROSPERO register, utilizing a modified extraction tool adapted from Cochrane. Eight studies were included after screening 1312 records. Five studies reanalyzed dried blood spots (DBS) on filter paper cards, and three studies utilized pre-existing results. The results of these studies and how they relate to cord blood studies, the use of cord blood versus newborn screening dried blood spots as a sample and considerations on newborn screening and diabetes research is further discussed. The timing of sampling of newborn screening allows insight into neonatal physiology in a catabolic state with minimal maternal and placental influence. This, combined with the wide coverage of newborn screening worldwide, may aid in our understanding of the origins of diabetes.

2018 ◽  
Vol 56 (2) ◽  
pp. 278-284 ◽  
Author(s):  
Theresa Winter ◽  
Anja Lange ◽  
Anke Hannemann ◽  
Matthias Nauck ◽  
Cornelia Müller

Abstract Background: Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Methods: Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Results: Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. Conclusions: A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.


Author(s):  
Mitsuhiro Haga ◽  
Mitsuhisa Isobe ◽  
Ken Kawabata ◽  
Masaki Shimizu ◽  
Hiroshi Mochizuki

Objective The acylcarnitine profile is analyzed in dried blood spots (DBS) to screen for inborn errors of metabolism. Hematocrit (Ht) is known to affect the result of quantitative analyses of DBS samples; however, the effects of Ht on the acylcarnitine profiles in DBS have not been studied in actual samples from newborns. Study Design The acylcarnitine profiles in DBS for newborn screening tests and Ht levels of very-low-birth-weight infants were obtained from medical records. We investigated the relationship between Ht and each acylcarnitine using Pearson's correlation coefficient (r). Results We examined 77 newborns in this study. There was a significantly positive correlation between Ht and C0, C2, C12, C16, C18, C18:1, and C18:1-OH, respectively (p < 0.0025). The correlation was the greatest on C2 (r = 0.59). Conclusion This study clarifies that Ht and C0, C2, C12, C16, C18, C18:1, and C18:1-OH are significantly correlated in DBS, which is consistent with previous studies. Hence, the effect of Ht should be considered when interpreting the results of acylcarnitine profiles in DBS. Key Points


2018 ◽  
Vol 71 (10) ◽  
pp. 885-889 ◽  
Author(s):  
Noriyuki Kaku ◽  
Kenji Ihara ◽  
Yuichiro Hirata ◽  
Kenji Yamada ◽  
Sooyoung Lee ◽  
...  

AimIt is estimated that 1–5% of sudden infant death syndrome (SIDS) cases might be caused by undiagnosed inborn errors of metabolism (IEMs); however, the postmortem identification of IEMs remains difficult. This study aimed to evaluate the usefulness of dried blood spots (DBSs) stored after newborn screening tests as a metabolic autopsy to determine the causes of death in infants and children who died suddenly and unexpectedly.MethodsInfants or toddlers who had suddenly died without a definite diagnosis between July 2008 and December 2012 at Kyushu University Hospital in Japan were enrolled in this study. Their Guthrie cards, which had been stored for several years at 4–8°C, were used for an acylcarnitine analysis by tandem mass spectrometry to identify inborn errors of metabolism.ResultsFifteen infants and children who died at less than 2 years of age and for whom the cause of death was unknown were enrolled for the study. After correcting the C0 and C8 values assuming the hydrolysation of acylcarnitine in the stored DBSs, the corrected C8 value of one case just exceeded the cut-off level for medium-chain acyl-CoA dehydrogenase (MCAD) deficiency screening. Genetic and biochemical analyses confirmed this patient to have MCAD deficiency.ConclusionDBSs stored after newborn screening tests are a promising tool for metabolic autopsy. The appropriate compensation of acylcarnitine data and subsequent genetic and biochemical analyses are essential for the postmortem diagnosis of inborn errors of metabolism.


2020 ◽  
Vol 10 (4(38)) ◽  
pp. 77-86
Author(s):  
Tetiana Znamenska ◽  
O. Vorobiova ◽  
I. Kuzneczov ◽  
I. Lastivka ◽  
A. Kremezna ◽  
...  

Introduction. Inborn Errors of Metabolism (IEM) are constituted a group of genetic diseases that are associated with defects in the synthesis or catabolism of complex molecules, impaired intermediary metabolism and energy production/utilization processes. The clinical manifestation of IEM is nonspecific, that looks similar to septicemia, and most often occurs in the neonatal period with life-threatening acute metabolic crises. Expanded Newborn Screening (ENS) – a biochemical study of the blood of all newborns without exception with the purpose to identify molecular markers of these diseases proved to be the most effective instrument of early IEM diagnostics. The quality of the biological samples (dried blood spots, DBS) in great extent determines the timing, accuracy, and reliability of the results of biochemical measurements. Obtaining of equivocal results in the case of analysis of poor quality DBS requires repeated laboratory tests, that delays the diagnostic process and postpones the start of specific treatment, which usually results in irreversible damage of the brain and internal organs of the child. The aim of this work is to (i) review the first results of the implementation of Expanded Newborn Screening in Ukraine (pilot part of the Baby Screen Project), and to analyze literature data regarding the negative impact of poor quality DBS on laboratory determination of IEM marker substances contents in the specimens, (ii) to characterize the typical errors in blood sampling and drying of  blood spots, and (iii) to provide practical recommendations for the proper performance of these procedures. Materials and methods. Own data of retrospective analysis of the questionable ENS results was superimposed with dried blood specimens, that were investigated in the Pharmbiotest ENS Lab to outline most common inaccuracies. Based on the comparison of these data with the relevant publications it was formulated the practical recommendations for improving quality of DBS preparation to ensure the accuracy and reliability of laboratory measurements and speed up IEM diagnostics. Results. The quality of biomaterial selection is an important part of obtaining reliable results during expanded newborn screening. Capillary blood is collected in the maternity hospital from 48-72 hours (full-term) and for 7-11 days (in preterm babies) after the birth from the heel of babies. In this case, a few drops of blood are applied to a special test card made of filter paper, which is dried and sent to the laboratory. Blood tests are performed using a highly sensitive and accurate method of chemical analysis - tandem mass spectrometry in the laboratory "Pharmbiotest", located in Ukraine. Taking into analysis the low-quality samples lead to questionable results, which requires repeated DBS sampling and re-examining. This proved to be the most common cause of delaying IEM detection, diagnosis establishment, and initiation of treatment, which can be fatal for a child with severe IEM forms. Conclusions. Informing healthcare professionals and parents about the current results of laboratory monitoring of dried blood spots quality, typical errors in blood sampling and following on-site procedures and negative consequences of its improper performance, as well as providing clear practical recommendations of how these procedures should be done is a proven way of improving and speeding up IEM diagnostics.


2021 ◽  
Vol 9 ◽  
Author(s):  
Erin L. Marcotte ◽  
Logan G. Spector ◽  
Daniela P. Mendes-de-Almeida ◽  
Heather H. Nelson

Childhood leukemias are heterogeneous diseases with widely differing incident rates worldwide. As circulating tumors, childhood acute leukemias are uniquely accessible, and their natural history has been described in greater detail than for solid tumors. For several decades, it has been apparent that most cases of childhood acute lymphoblastic leukemia (ALL) and acute myeloid leukemia (AML) initiate in utero. Circumstantial evidence in support of this contention includes the young age of onset and high rate of concordance among identical twins. “Backtracking” of leukemic somatic mutations, particularly gene translocations, to cord blood and dried blood spots collected during the perinatal period has provided molecular proof of prenatal leukemogenesis. Detection of a patient's leukemia translocation in easily accessible birth samples, such as dried blood spots, is straightforward with the knowledge of their idiosyncratic breakpoints. However, to translate these findings into population-based screening and leukemia prevention requires novel methods able to detect translocations at all possible breakpoints when present in a low frequency of cells. Several studies have attempted to screen for leukemic translocations, mainly the common ETV6-RUNX1 translocation, in cord blood samples from healthy children. Most studies have reported finding translocations in healthy children, but estimates of prevalence have varied widely and greatly exceed the incidence of leukemia, leading to concerns that technical artifact or contamination produced an artificially inflated estimate of translocation prevalence at birth. New generation techniques that capture the presence of these translocations at birth have the potential to vastly increase our understanding of the epidemiology of acute leukemias. For instance, if leukemic translocations are present at birth in a far higher proportion of children than eventually develop acute leukemia, what are the exposures and somatic molecular events that lead to disease? And could children with translocations present at birth be targeted for prevention of disease? These questions must be answered before large-scale newborn screening for leukemia can occur as a public health initiative. Here, we review the literature regarding backtracking of acute leukemias and the prevalence of leukemic translocations at birth. We further suggest an agenda for epidemiologic research using new tools for population screening of leukemic translocations.


2021 ◽  
Vol 26 ◽  
pp. 100720
Author(s):  
Archana Natarajan ◽  
Rita Christopher ◽  
Shruti V. Palakuzhiyil ◽  
Sadanandavalli Retnaswami Chandra

2013 ◽  
Vol 419 ◽  
pp. 73-76 ◽  
Author(s):  
Wei-Lien Chuang ◽  
Josh Pacheco ◽  
X. Kate Zhang ◽  
Monica M. Martin ◽  
Chad K. Biski ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document