scholarly journals Impact of Coping Veneering Techniques on the Survival of Implant-Supported Zirconia-Based-Crowns Cemented to Hybrid-Abutments: An-In-Vitro Study

2020 ◽  
Vol 7 (4) ◽  
pp. 117
Author(s):  
Shareen Hayel Elshiyab ◽  
Noor Nawafleh ◽  
Usman Khan ◽  
Andreas Öchsner ◽  
Roy George

The objective of this study is to investigate the influence of veneering technique (hand-layering vs. milling) on the fracture resistance of bi-layer implant-supported zirconia-based hybrid-abutment crowns. Mandibular molar copings were anatomically designed and milled. Copings were then veneered by hand-layering (HL) (n = 20) and milling using the Cad-On technique (LD) (n = 20). Crowns were cemented to zirconia hybrid-abutments. Ten samples of each group acted as a control while the remaining ten samples were subjected to fatigue in a chewing simulator. Crowns were loaded between 50 and 100 N for 1.2 million cycles under simultaneous temperature fluctuation between 5 and 55 °C. Crowns were then subjected to static load a to fracture test. Data were statistically analysed using the one-way ANOVA. Randomly selected crowns from each group were observed under scanning electron microscopy to view fractured surfaces. Study results indicate that during fatigue, LD crowns had a 100% survival rate; while HL crowns had a 50% failure rate. Fracture resistance of LD crowns was statistically significantly higher than that of HL crowns at the baseline and after fatigue (p ≤ 0.05). However, fatigue did not cause a statistically significant reduction in fracture resistance in both LD and HL groups (p > 0.05). Copings fractured in the LD crowns only and the fracture path was different in both LD and HL groups. According to the results, it was concluded that milled veneer implant-supported hybrid-abutment crowns exhibit significantly higher fracture resistance, and better withstand clinical masticatory loads in the posterior region compared to the hand-layered technique. Also, fatigue application and artificial aging caused no significant strength reduction in both techniques. Clinical significance: Different veneering techniques and materials (hand-layering or milling) act differently to clinical forces and environment and may be prone to early chipping during service. Therefore, practitioners are urged to consider the appropriate veneering protocol for posterior implant-supported hybrid-abutment restorations.

Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


2021 ◽  
pp. 232020682199798
Author(s):  
Beyza Unalan Degirmenci ◽  
Alperen Degirmenci ◽  
Emine Kara

Aim: Natural antioxidants were offered as the answer of dentin adhesion issue. The aim of this study is to investigate the effects of proanthocyanidin and lycopene as pretreatment agents on the sound and caries-affected dentin surface on microtensile bond strength and microleakage. Materials and Methods: This study was designed as in vitro because of that 84 mandibular molar teeth were collected. Forty-two of the included teeth were carious teeth, while the other 42 were without caries. Sixty of them were used for microleakage and 24 for microtensile bond strength testing and scanning electron microscopy analysis. The samples were divided into six subgroups randomly according to dentin pretreatments: 5% proanthocyanidin, 5% lycopene, and no antioxidant application. After the restorative procedures, samples were attached to the microtensile tester. Samples were subjected to tensile stress in the load cell until they broke at a speed of 0.5 mm per min. Microtensile bond strength (µTBS) and microleakage test data were analyzed with two-way analysis of variance, Bonferroni correction, and Tamhane’s T2 tests. Results: Two-way variance analysis showed that dentin pretreatment applications, dentin substrate, and the interaction between these two parameters had statistically significant effects on µTBS values ( P < .001). There was no difference between dentin pretreatment applications in terms of microleakage scores ( P > .05). Conclusion: The application of dentin pretreatment with proanthocyanidin is a successful procedure that increases the bond strength in both dentin substrate, while pretreatment with lycopene in caries-affected dentin reduces it.


2019 ◽  
Vol 61 (2) ◽  
pp. 253-259
Author(s):  
Iroshani Kodikara ◽  
Iroshini Abeysekara ◽  
Dhanusha Gamage ◽  
Isurani Ilayperuma

Background Volume estimation of organs using two-dimensional (2D) ultrasonography is frequently warranted. Considering the influence of estimated volume on patient management, maintenance of its high accuracy is empirical. However, data are scarce regarding the accuracy of estimated volume of non-globular shaped objects of different volumes. Purpose To evaluate the volume estimation accuracy of different shaped and sized objects using high-end 2D ultrasound scanners. Material and Methods Globular (n=5); non-globular elongated (n=5), and non-globular near-spherical shaped (n=4) hollow plastic objects were scanned to estimate the volumes; actual volumes were compared with estimated volumes. T-test and one-way ANOVA were used to compare means; P<0.05 was considered significant. Results The actual volumes of the objects were in the range of 10–445 mL; estimated volumes ranged from 6.4–425 mL ( P=0.067). The estimated volume was lower than the actual volume; such volume underestimation was marked for non-globular elongated objects. Regardless of the scanner, the highest volume estimation error was for non-globular elongated objects (<40%) followed by non-globular near-spherical shaped objects (<23.88%); the lowest was for globular objects (<3.6%). Irrespective of the shape or the volume of the object, volume estimation difference among the scanners was not significant: globular (F=0.430, P=0.66); non-globular elongated (F=3.69, P=0.064); and non-globular near-spherical (F=4.00, P=0.06). A good inter-rater agreement (R=0.99, P<0.001) and a good correlation between actual versus estimated volumes (R=0.98, P<0.001) were noted. Conclusion The 2D ultrasonography can be recommended for volume estimation purposes of different shaped and different sized objects, regardless the type of the high-end scanner used.


2021 ◽  
pp. 088532822110195
Author(s):  
Moataz Elsisy ◽  
Mahdis Shayan ◽  
Yanfei Chen ◽  
Bryan W Tillman ◽  
Catherine Go ◽  
...  

Nitinol is an excellent candidate material for developing various self-expanding endovascular devices due to its unique properties such as superelasticity, biocompatibility and shape memory effect. A low-energy laser joining technique suggests a high potential to create various large diameter Nitinol endovascular devices that contain complex geometries. The primary purpose of the study is to investigate the effects of laser joining process parameters with regard to the mechanical and biocompatible performance of Nitinol stents. Both the chemical composition and the microstructure of the laser-welded joints were evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). In vitro study results on cytotoxicity demonstrated that the joining condition of 8 Hz frequency and 1 kW laser power showed the highest degree of endothelial cell viability after thermal annealing in 500°C for 30 min. Also, in vitro study results showed the highest oxygen content at 0.9 kW laser power, 8 Hz frequency, and 0.3 mm spot size after the thermal annealing. Mechanical performance test results showed that the optimal condition for the highest disconnecting force was found at 1 Hz frequency and 1 kW power with 0.6 mm spot size. Two new endovascular devices have been fabricated using the optimized laser joining parameters, which have demonstrated successful device delivery and retrieval, as well as acute biocompatibility.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6753
Author(s):  
Ramona S. Oltramare ◽  
Reto Odermatt ◽  
Phoebe Burrer ◽  
Thomas Attin ◽  
Tobias T. Tauböck

The aim of this in vitro study was to investigate the degree of C=C double bond conversion of high-viscosity dimethacrylate- or ormocer-based bulk-fill composites as a function of measurement depth. Four bulk-fill composites (Tetric EvoCeram Bulk Fill, x-tra fil, SonicFill, and Bulk Ormocer) and the conventional nanohybrid composite Tetric EvoCeram were applied in standardized Class II cavities (n = 6 per group) and photoactivated for 20 s at 1350 mW/cm2. The degree of conversion of the composites was assessed using Fourier-transform infrared spectroscopy at seven measurement depths (0.15, 1, 2, 3, 4, 5, 6 mm). Data were analyzed using repeated measures ANOVA and one-way ANOVA with Bonferroni post-hoc tests (α = 0.05). The investigated bulk-fill composites showed at least 80% of their maximum degree of conversion (80% DCmax) up to a measuring depth of at least 4 mm. Tetric EvoCeram Bulk Fill and Bulk Ormocer achieved more than 80% DCmax up to a measuring depth of 5 mm, x-tra fil up to 6 mm. The conventional nanohybrid composite Tetric EvoCeram achieved more than 80% DCmax up to 3 mm. In contrast to the conventional composite, the investigated ormocer- and dimethacrylate-based bulk-fill composites can be photo-polymerized in thick layers of up to at least 4 mm with regard to their degree of C=C double bond conversion.