scholarly journals Flaw Classification Algorithm for Heat Exchanger Tubes Using a Bobbin-Type Magnetic Camera

2019 ◽  
Vol 9 (23) ◽  
pp. 5000
Author(s):  
Sim ◽  
Lee ◽  
Lee ◽  
Lee

This paper presents an algorithm that estimates the presence, location, shape, and depth of flaws using a bobbin-type magnetic camera consisting of bobbin probes and a bobbin-type integrated giant magnetoresistance (GMR) sensor array (BIGiS). The presence of the flaws is determined by the lobe path of the Lissajous curves obtained from bobbin coil with respect to the applied frequency. The location of the flaw, i.e., whether it is an inner diameter (ID) or outer diameter (OD) flaw, can be determined from the rotational direction of the lobe with respect to the frequency change. The shape of the flaw is then determined from the area of the lobe and the BIGiS image. At this stage, multi-site damage can be determined from the BIGiS image. The effectiveness of the flaw classification algorithm was evaluated using various types of artificial flaws introduced into small-bore tube test specimens made of austenitic stainless steel.

2016 ◽  
Vol 2016 ◽  
pp. 1-15 ◽  
Author(s):  
Rui Wang ◽  
Youhei Kawamura

Corrosion is one of the main causes of deterioration of steel bridges. It may cause metal loss and fatigue cracks in the steel components, which would lead to the collapse of steel bridges. This paper presents an automated sensing system to detect corrosion, crack, and other kinds of defects using a GMR (Giant Magnetoresistance) sensor array. Defects will change the relative permeability and electrical conductivity of the material. As a result, magnetic field density generated by ferromagnetic material and the magnetic wheels will be changed. The defects are able to be detected by using GMR sensor array to measure the changes of magnetic flux density. In this study, magnetic wheels are used not only as the adhesion device of the robot, but also as an excitation source to provide the exciting magnetic field for the sensing system. Furthermore, compared to the eddy current method and the MFL (magnetic flux leakage) method, this sensing system suppresses the noise from lift-off value fluctuation by measuring the vertical component of induced magnetic field that is perpendicular to the surface of the specimen in the corrosion inspection. Simulations and experimental results validated the feasibility of the system for the automated defect inspection.


Author(s):  
Fanda Meng ◽  
Weisong Huo ◽  
Jie Lian ◽  
Lei Zhang ◽  
Xizeng Shi ◽  
...  

AbstractWe report a microfluidic sandwich immunoassay constructed around a dual-giant magnetoresistance (GMR) sensor array to quantify the heart failure biomarker NT-proBNP in human plasma at the clinically relevant concentration levels between 15 pg/mL and 40 ng/mL. The broad dynamic range was achieved by differential coating of two identical GMR sensors operated in tandem, and combining two standard curves. The detection limit was determined as 5 pg/mL. The assay, involving 53 plasma samples from patients with different cardiovascular diseases, was validated against the Roche Cobas e411 analyzer. The salient features of this system are its wide concentration range, low detection limit, small sample volume requirement (50 μL), and the need for a short measurement time of 15 min, making it a prospective candidate for practical use in point of care analysis.


Diagnostics ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1145
Author(s):  
Magdalena Kal ◽  
Izabela Chojnowska-Ćwiąkała ◽  
Mateusz Winiarczyk ◽  
Monika Jasielska ◽  
Jerzy Mackiewicz

Background: The aim of this study was to evaluate the quantitative morphological changes in lamellar macular holes (LMHs) based on SD-OCT examinations and to assess the correlations among minimal retinal thickness (MRT), reading vision (RV), and best corrected visual acuity (BCVA) over a 36-month follow-up period. Methods: A group of 40 patients (44 eyes) with LMH was evaluated, with an average age of 69.87 (SD = 10.14). The quantitative parameters monitored in the follow-up period (at 0, 3, 6, 12, 18, 24, 30, and 36 months) were tested for normality of distribution by Shapiro–Wilk and Kolmogorov–Smirnov tests. Results: The RV and BCVA values were stable, and no significant changes were found at any of the check-ups during the 36-month follow-up period (BCVA p = 0.435 and RV p = 0.0999). The analysis of individual quantitative LMH parameters during the 36-month follow-up period did not demonstrate statistically significant differences: MRT (p = 0.461), Max RT temporal (p = 0.051), Max RT nasal (p = 0.364), inner diameter (ID) (p = 0.089), and outer diameter (OD) (p = 0.985). Conclusions: The observations at 0, 6, 12, 18, 24, 30, and 36 months revealed moderate and significant correlations between RV and MRT. No significant correlation between BCVA and MRT was observed.


Author(s):  
Ajay Kumar Kaviti ◽  
Akkala Siva Ram ◽  
Amit Kumar Thakur

In this experimental study, permanent magnets with three different sizes (M-1: 32 mm inner diameter, 70 mm outer diameter and 15 mm thick, M-2: 25 mm inner diameter, 60 mm outer diameter and 10 mm thick, M-3: 22 mm inner diameter, 45 mm outer diameter and 9 mm thick) are fully submerged in the single-slope glass solar still. The performance of magnetic solar stills (MSS) with three different sizes at 2 cm depth water to ensure that magnets are fully submerged is compared with conventional solar still (CSS) at the location 17.3850°N, 78.4867°E. Tiwari model is adapted to calculate the heat transfer coefficients (HTC), internal and exergy efficiencies. MSS with M-1, M-2 and M-3 significantly enhanced the convective, radiative, and evaporative heat transfer rate for the 2 cm depth of water. This is due to the desired magnetic treatment of water, which reduces the surface tension and increases the hydrogen bonds. The MSS's total internal HTC, instantaneous efficiencies led CSS by 25.52%, 28.8%, respectively, with M-1. Having various magnetic fields due to different magnets sizes increases MSS's exergetic efficiency by 33.61% with M-1, 33.76% with M-2, and 42.25% with M-3. Cumulative yield output for MSS with M-1, M-2, and M-3 is 21.66%, 17.64%, 15.78% higher than CSS. The use of permanent magnets of different sizes in the MSS is a viable, economical and straight forward technique to enhance productivity.


1995 ◽  
Vol 4 (6) ◽  
pp. 597-608 ◽  
Author(s):  
Jiro Hirai ◽  
Takehisa Matsuda

A tubular, hierarchically structured hybrid vascular tissue composed of vascular cells and collagen was prepared. First, a cold mixed solution of bovine aortic smooth muscle cells (SMCs) and Type I collagen was poured into a tubular glass mold composed of a mandrel and a sheath (example of dimensions: inner diameter, 1.5 mm; outer diameter, 7 mm; length, 7 cm). Upon incubation at 37°C, an SMC-incorporated collagenous gel was formed. After the sheath was removed, the resulting fragile tissue, when cultured in medium, thinned in a time-dependent manner to form an opaque, dense tissue. Higher SMC seeding density and lower initial collagen concentration induced more rapid and prominent shrinkage of the tissue. Morphologic investigation showed that over time, bipolarly elongated SMCs and collagen fiber bundles became positioned around the mandrel. Both components became circumferentially oriented. When the mandrel was removed, a tubular hybrid medial tissue was formed. A hybrid vascular tissue with a hierarchical structure was constructed by seeding endothelial cells onto the inner surface of the hybrid medial tissue. Prepared tissues tolerated luminal pressures as great as 100 mmHg and mechanical stress applied during an anastomotic procedure. This method allowed us to prepare a tubular hybrid medial tissue of predetermined size (inner diameter, wail thickness, and length) by selecting appropriate mold design, initial collagen concentration, and SMC seeding density. Such hybrid vascular tissues may provide physiological functions when implanted into the venous system.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Rania A. Ahmed

Purpose. To study features of the lower punctum in normal subjects using spectral domain anterior segment optical coherence tomography (SD AS-OCT).Methods. Observational cross-sectional study that included 147 punctae (76 subjects). Punctae were evaluated clinically for appearance, position, and size. AS-OCT was used to evaluate the punctal shape, contents, and junction with the vertical canaliculus. Inner and outer diameters as well as depth were measured.Results. 24 males and 52 females (mean age44±14.35 y) were included. Lower punctum was perceived by OCT to be an area with an outer diameter (mean412.16±163 μm), inner diameter (mean233.67±138.73 μm), and depth (mean251.7±126.58 μm). The OCT measured outer punctum diameter was significantly less than that measured clinically (P: 0.000). Seven major shapes were identified. The junction with the vertical canaliculus was detectable in 44%. Fluid was detected in 34%, one of which had an air bubble; however, 63% of punctae showed no contents and 4% had debris.Conclusions. AS-OCT can be a useful tool in understanding the anatomy of the punctum and distal lacrimal system as well as tear drainage physiology. Measuring the punctum size may play a role in plugs fitting.


2019 ◽  
Vol 98 (4) ◽  
pp. 455-460
Author(s):  
Lyudmila V. Akhaltseva ◽  
V. S. Zhurkov ◽  
L. P. Sycheva ◽  
O. N. Savostikova ◽  
A. V. Alekseeva

Introduction. One of the important steps in assessing the nanoparticles (NP) safety is the analysis of mutagenic activity, including the evaluation of gene, chromosomal, and genomic mutations. Material and methods. The purpose of this investigation is to study the ability of different NP aqueus suspensions and the same compounds in microforms to unduce gene mutations in Salmonella/microsome test (Ames test). Anatase titanium dioxide NP coated with simethicone (33.16 ± 16.7 nm, 5-50000 μg/ml), magnetite NP coated with silicate (10 nm, 0.92-575 μg/ml), silver NP coated with аrabian gum (14 ± 0.2 nm, 5-50000 μg/ml), aluminum hydroxide nanofibres (50-70 nm, 24-3000 μg/ml) and multi-walled carbon nanotubes (Taunit MWСNTs, outer diameter 15-40 nm, inner diameter 3-8 nm, length 2 and more microns, 5-50000 μg/ml). In parallel, the mutagenic activity of equivalent microparticles was evaluated in experiments. Ames test (Salmonella/microsomes) registers gene mutations induced by a different mechanism of action, in the variant with preincubation. A set of Salmonella typhimurium indicator strains: TA 100 (base pair substitution mutations), TA 98 and TA 97 (mutations of the frameshift type of the genetic code) were used. Using addition the S9 microsomal activating mixture during the experiment makes it is possible to determine the effect not only of the substances themselves, but also of their metabolites. Conclusion. The investigated nanomaterials as well as their micro analogs in the studied dose range did not induce gene mutations in the Ames test both in presence and absence microsomal activating mixture.


2006 ◽  
Vol 21 (2) ◽  
pp. 529-534 ◽  
Author(s):  
Jun-ichi Minato ◽  
Kun'ichi Miyazawa

Crystalline microtubes (inner diameter 240–2100 nm) consisting of C60 fullerene molecules were prepared in the mixture of C60-saturated pyridine and isopropyl alcohol kept at 0 °C. Characterization by transmission electron microscopy showed a linear relationship between the outer diameter and the inner diameter for the C60 fullerene tubes. Optical observations suggested that the specimens already had tubular structure when they were grown in the solution. Deposition of guest crystals inside the C60 fullerene tubes was performed by the following procedure: (i) ultrasonic pulverization to obtain the C60 fullerene tubes with open ends, (ii) absorption of methyl alcohol solution of KBr into the tubes by the capillary attraction, and (iii) evaporation of methyl alcohol to precipitate KBr inside the tubes. Columnar KBr crystals were then obtained by dissolving the fullerene tube walls in toluene.


Clay Minerals ◽  
1983 ◽  
Vol 18 (4) ◽  
pp. 459-472 ◽  
Author(s):  
V. C. Farmer ◽  
M. J. Adams ◽  
A. R. Fraser ◽  
F. Palmieri

AbstractThe unique properties of imogolite are closely related to its structure, which is a tube of 23–27 Å outer diameter and ∼10 Å inner diameter, with an AIOH outer surface and SiOH inner surface. Acid dispersions contain the long, positively-charged tubes as isolated units or small bundles, which form bulky gels in alkali, and flocculate with negatively-charged colloids, polyvalent anions, and long-chain anionic detergents. Sorption properties are associated with the 10 Å intra-tube pores and with inter-tube channels of variable dimensions. Surface acidity is less than that of layer-silicate clays. The chemical and mechanical stability, biological activity, film- and fibre-forming characteristics, and conditions of synthesis are reviewed, on the basis of both new and published findings. Areas of potential application are indicated.


Sign in / Sign up

Export Citation Format

Share Document