scholarly journals Direction for High-Performance Supercritical CO2 Centrifugal Compressor Design for Dry Cooled Supercritical CO2 Brayton Cycle

2019 ◽  
Vol 9 (19) ◽  
pp. 4057 ◽  
Author(s):  
Cho ◽  
Bae ◽  
Jeong ◽  
Lee ◽  
Lee

To overcome the degradation of the cycle efficiency of a supercritical carbon dioxide (S-CO2) Brayton cycle with dry cooling, this study proposes an improved design of an S-CO2 centrifugal compressor. The conventional air centrifugal compressor can achieve higher efficiency as backsweep angle increases. However, the structural issue restricts the maximum allowable angle (−50~−56°). In this study, an S-CO2 centrifugal compressor performance was examined while changing the backward sweep angle at impeller exit to study if the previous optimum backsweep angle for an air centrifugal compressor is still valid when the fluid has changed. It is shown through an analysis that an S-CO2 centrifugal compressor can achieve the highest efficiency at −70° backsweep angle, which is greater than the typical design value. The S-CO2 centrifugal compressor is less restricted from a structural integrity issue because it has low relative Mach number regardless of the low sound speed near critical point (Tc = 304.11 K, Pc = 7377 kPa). It is also shown in the paper that the variation of compressibility factor does not impact on its total to total efficiency since its Mach number is still lower than unity. Finally, it is also shown that a backward sweep impeller can achieve higher pressure ratio and operate stably in wider range as the mass flow rate is decreased. As further works, the suggested concept will be validated by the structural analysis and the compressor performance test.

1990 ◽  
Vol 112 (1) ◽  
pp. 25-29 ◽  
Author(s):  
H. Hayami ◽  
Y. Senoo ◽  
K. Utsunomiya

Low-solidity circular cascades, conformally transformed from high-stagger linear cascades of double-circular-arc vanes with solidity 0.69, were used as a part of the diffuser system of a transonic centrifugal compressor. Performance test results were compared with data of the same compressor with a vaneless diffuser. Good compressor performance and a wider flow range as well as a higher pressure ratio and a higher efficiency, superior to those with a vaneless diffuser, where the flow range was limited by choke of the impeller, were demonstrated. The test circular cascade diffusers demonstrated a good pressure recovery over a wide range of flow angles, even when the inflow Mach number to the cascade was over unity.


Author(s):  
Masanori Aritomi ◽  
Takao Ishizuka ◽  
Yasushi Muto ◽  
Nobuyoshi Tsuzuki

Supercritical carbon dioxide (S-CO2) gas turbines can generate power at high cycle thermal efficiency, even at modest temperatures of 500–550°C, because of their markedly reduced compressor work near the critical point. Furthermore, the reaction between Na and CO2 is milder than that between H2O and Na. A more reliable and economically advantageous power generation system could be achieved by coupling with a sodium-cooled fast reactor. At Tokyo Institute of Technology, numerous development projects have been conducted for development of this system in cooperation with JAEA. Supercritical CO2 compressor performance test results are given as described herein. A centrifugal compressor is chosen for the performance test. Main compressor parts are stored in a pressure vessel. Maximum design conditions of the supercritical CO2 test apparatus are pressure of 11 MPa, temperature of 150°C, the flow rate of 6 kg/s and rotational speed of 24,000 rpm. The centrifugal compressor has an electric motor with permanent magnets on the rotor surface, with speed control by an inverter up to 24,000 rpm, a rotor shaft for the impeller, and a motor supported by gas bearings. Different compressor design points are examined using impellers of three kinds; test data are obtained using those impellers under steady state conditions with changing pressure, temperature, flow rate, and compressor rotor speed. The pressure ratio (compressor outlet pressure/inlet pressure) is obtained with the function of compressor rotational speed and the fluid flow rate. The data cover a broad region from sub-critical to supercritical pressure. Such data were obtained for the first time. No unstable phenomenon was observed in the area where the CO2 properties change sharply. Data of the pressure ratio vs. flow rate were coincident with the fundamental compressor theory.


Author(s):  
H. Hayami ◽  
Y. Senoo ◽  
K. Utsunomiya

Low-solidity circular cascades, conformally transformed from high-stagger linear cascades of double-circular-arc vanes with solidity 0.69, were used as a part of the diffuser system of a transonic centrifugal compressor. Performance test results were compared with data of the same compressor with a vaneless diffuser. Good compressor performance, a wider flow range as well as a higher pressure ratio and a higher efficiency, superior to those with a vaneless diffuser, where the flow range was limited by choke of the impeller, were demonstrated. The test circular cascade diffusers demonstrated a good pressure recovery over a wide range of flow angles, even when the inflow Mach number to the cascade was over unity.


Author(s):  
Hideaki Tamaki

Centrifugal compressors used for turbochargers need to achieve a wide operating range. The author has developed a high pressure ratio centrifugal compressor with pressure ratio 5.7 for a marine use turbocharger. In order to enhance operating range, two different types of recirculation devices were applied. One is a conventional recirculation device. The other is a new one. The conventional recirculation device consists of an upstream slot, bleed slot and the annular cavity which connects both slots. The new recirculation device has vanes installed in the cavity. These vanes were designed to provide recirculation flow with negative preswirl at the impeller inlet, a swirl counterwise to the impeller rotational direction. The benefits of the application of both of the recirculation devices were ensured. The new device in particular, shifted surge line to a lower flow rate compared to the conventional device. This paper discusses how the new recirculation device affects the flow field in the above transonic centrifugal compressor by using steady 3-D calculations. Since the conventional recirculation device injects the flow with positive preswirl at the impeller inlet, the major difference between the conventional and new recirculation device is the direction of preswirl that the recirculation flow brings to the impeller inlet. This study focuses on two effects which preswirl of the recirculation flow will generate. (1) Additional work transfer from impeller to fluid. (2) Increase or decrease of relative Mach number. Negative preswirl increases work transfer from the impeller to fluid as the flow rate reduces. It increases negative slope on pressure ratio characteristics. Hence the recirculation flow with negative preswirl will contribute to stability of the compressor. Negative preswirl also increases the relative Mach number at the impeller inlet. It moves shock downstream compared to the conventional recirculation device. It leads to the suppression of the extension of blockage due to the interaction of shock with tip leakage flow.


Author(s):  
Ce Yang ◽  
Ben Zhao ◽  
C. C. Ma ◽  
Dazhong Lao ◽  
Mi Zhou

Two different inlet configurations, including a straight pipe and a bent pipe, were experimentally tested and numerically simulated using a high-speed, low-mass flow centrifugal compressor. The pressure ratios of the compressor with the two inlet configurations were tested and then compared to illustrate the effect of the bent inlet pipe on the compressor. Furthermore, different circumferential positions of the bent inlet pipe relative to the volute are discussed for two purposes. One purpose is to describe the changes in the compressor performance that result from altering the circumferential position of the bent inlet pipe relative to the volute. This change in performance may be the so-called clocking effect, and its mechanism is different from the one in multistage turbomachinery. The other purpose is to investigate the unsteady flow for different matching states of the bent inlet pipe and volute. Thus, the frequency spectrum of unsteady pressure fluctuation was applied to analyze the aerodynamic response. Compared with the straight inlet pipe, the experimental results show that the pressure ratio is modulated and that the choke point is shifted in the bent inlet pipe. Similarly, the pressure ratio can be influenced by altering the circumferential position of the bent inlet pipe relative to the volute, which may have an effect on the unsteady pressure in the rotor section. Therefore, the magnitude of interest spectral frequency is significantly changed by clocking the bent inlet pipe.


Author(s):  
Mohammad R. Aligoodarz ◽  
Mohammad Reza Soleimani Tehrani ◽  
Hadi Karrabi ◽  
Mohammad R. Roshani

Turbo machineries including compressors performance degrades over the period of operation and deviates from design levels due to causes including dust entrance into the compressor, blades mechanical damage, erosion and corrosion. These lead to reduction in compressor performance, efficiency and pressure ratio. Subsequently gas turbine performance is affected since their operation sate is correlated. In this study the numerical investigation of common causes that determine geometric characteristics of a 2-stage centrifugal compressor running in a gas station, including blades fouling and corrosion is performed. 3D Numerical modeling is implemented along with utilization of Shear Stress Transport (SST) turbulence model and independency from the grids is verified.


Author(s):  
Pau Cutrina Vilalta ◽  
Hui Wan ◽  
Soumya S. Patnaik

Abstract In this paper, we use various regression models and Artificial Neural Network (ANN) to predict the centrifugal compressor performance map. Particularly, we study the accuracy and efficiency of Gaussian Process Regression (GPR) and Artificial Neural Networks in modelling the pressure ratio, given the mass flow rate and rotational speed of a centrifugal compressor. Preliminary results show that both GPR and ANN can predict the compressor performance map well, for both interpolation and extrapolation. We also study the data augmentation and data minimzation effects using the GPR. Due to the inherent pressure ratio data distribution in mass-flow-rate and rotational-speed space, data augmentation in the rotational speed is more effective to improve the ANN performance than the mass flow rate data augmentation.


Author(s):  
Ziliang Li ◽  
Xingen Lu ◽  
Ge Han ◽  
Yanfeng Zhang ◽  
Shengfeng Zhao ◽  
...  

Centrifugal compressors often suffer relatively low efficiency and a terrible operating range particularly due to the complex flow structure and intense impeller/diffuser interaction. Numerous studies have focused on improving the centrifugal compressor performance using many innovative ideas, such as the tandem impeller, which has become increasingly attractive due to its ability to achieve the flow control with no additional air supply configurations and control costs in compressor. However, few studies that attempted to the investigation of tandem impeller have been published until now and the results are always contradictory. To explore the potential of the tandem impeller to enhance the compressor performance and the underlying mechanism of the flow phenomena in the tandem impellers, this paper numerically investigated a high-pressure-ratio centrifugal compressor with several tandem impellers at off-design operating speeds. The results encouragingly demonstrate that the tandem impeller can achieve a performance enhancement over a wide range of operating conditions. Approximately 1.8% maximum enhancement in isentropic efficiency and 5.0% maximum enhancement in operating range are achieved with the inducer/exducer circumferential displacement of [Formula: see text] = 25% and 50%, respectively. The observed stage performance gain of the tandem impellers decreases when the operating speed increases due to the increased inducer shock, increased wake losses, and deteriorated tandem impeller discharge flow uniformity. In addition, the tandem impeller can extend the impeller operating range particularly at low rotation speeds, which is found to be a result from the suppression of the low-momentum fluid radial movement. The results also indicate that the maximum flux capacity of the tandem impeller decreases due to the restriction of the inducer airfoil Kutta–Joukowsky condition.


Author(s):  
Hirotaka Higashimori ◽  
Susumu Morishita ◽  
Masayuki Suzuki ◽  
Tooru Suita

Requirements for aeronautical gas turbine engines for helicopters include small size, low weight, high output, and low fuel consumption. In order to achieve these requirements, development work has been carried out on high pressure ratio compressors with high efficiency. As a result, we have developed a single stage centrifugal compressor with a pressure ratio of 11 for a 1000 shp class gas turbine. This report presents a study on the internal flow of a high pressure ratio centrifugal compressor impeller. The centrifugal compressor is a high transonic compressor with an inlet Mach number of about 1.6. In high inlet Mach number compressors, the flow in the inducer is a complex transonic flow characterized by interaction between the shockwave and boundary layer, while the flow in the middle of the impeller is a distorted flow with a low energy region. In order to ensure the reliability of aerodynamic design technology for such transonic centrifugal compressors, the complex transonic flow and formation of the low energy region predicted by CFD must be actually measured, comparison must be undertaken between the CFD results and the actual flow measurement, and the accuracy and other issues pertaining to CFD must be clarified. In a previous report [12], we elucidated the flow in the inducer of a high transonic impeller by means of LDV and unsteady pressure measurement. That report showed that, in the flow of an inducer with a Mach number of approx. 1.6, the oblique shockwave in the middle of the impeller throat interacts with the blade tip leakage flow, and that reverse flow occurs in the vicinity of the casing. Furthermore, although CFD predicted a low energy region in the splitter portion, this could not be detected in actual measurement. In the context of the current report, comparative verification of the CFD and LDV measurement results was undertaken with respect to the formation of the casing wall surface boundary layer in the transonic flow within the inducer. In this conjunction, inducer bleed was introduced to control this boundary layer, and the effect of the inducer bleed on the flow was ascertained through actual measurement. It was also sought to additionally confirm the “low energy region” in the splitter. Accordingly, the flow velocity distribution was measured at two sections, thereby clarifying the characteristics of the actual flow in the region. The impeller for which measurement was performed has the same specifications as that in the previous report (see Table 1). In the present report, so as to measure the flow under conditions encouraging the formation of a boundary layer accompanying substantial inducer deceleration, measurement was conducted at 95% of design speed and a relative Mach number at the blade tips of about 1.5.


Sign in / Sign up

Export Citation Format

Share Document