scholarly journals Toward Long-Term Implantable Glucose Biosensors for Clinical Use

2019 ◽  
Vol 9 (10) ◽  
pp. 2158 ◽  
Author(s):  
Yun Jung Heo ◽  
Seong-Hyok Kim

Continuous glucose monitoring (CGM) sensors have led a paradigm shift to painless, continuous, zero-finger pricking measurement in blood glucose monitoring. Recent electrochemical CGM sensors have reached two-week lifespans and no calibration with clinically acceptable accuracy. The system with the recent CGM sensors is identified as an “integrated glucose monitoring system,” which can replace finger-pricking glucose-testing for diabetes treatment decisions. Although such innovation has brought CGM technology closer to realizing the artificial pancreas, discomfort and infection problems have arisen from short lifespans and open wounds. A fully implantable sensor with a longer-term lifespan (90 days) is considered as an alternative CGM sensor with high comfort and low running cost. However, it still has barriers, including surgery for applying and replacing and frequent calibration. If technical refinement is conducted (e.g., stability and reproducibility of sensor fabrication), fully implantable, long-term CGM sensors can open the new era of continuous glucose monitoring.

2020 ◽  
Vol 8 ◽  
Author(s):  
Yating Chen ◽  
Yulan Tian ◽  
Ping Zhu ◽  
Liping Du ◽  
Wei Chen ◽  
...  

Continuous intensive monitoring of glucose is one of the most important approaches in recovering the quality of life of diabetic patients. One challenge for electrochemical enzymatic glucose sensors is their short lifespan for continuous glucose monitoring. Therefore, it is of great significance to develop non-enzymatic glucose sensors as an alternative approach for long-term glucose monitoring. This study presented a highly sensitive and selective electrochemical non-enzymatic glucose sensor using the electrochemically activated conductive Ni3(2,3,6,7,10,11-hexaiminotriphenylene)2 MOFs as sensing materials. The morphology and structure of the MOFs were investigated by scanning SEM and FTIR, respectively. The performance of the activated electrode toward the electrooxidation of glucose in alkaline solution was evaluated with cyclic voltammetry technology in the potential range from 0.2 V to 0.6 V. The electrochemical activated Ni-MOFs exhibited obvious anodic (0.46 V) and cathodic peaks (0.37 V) in the 0.1 M NaOH solution due to the Ni(II)/Ni(III) transfer. A linear relationship between the glucose concentrations (ranging from 0 to 10 mM) and anodic peak currents with R2 = 0.954 was obtained. It was found that the diffusion of glucose was the limiting step in the electrochemical reaction. The sensor exhibited good selectivity toward glucose in the presence of 10-folds uric acid and ascorbic acid. Moreover, this sensor showed good long-term stability for continuous glucose monitoring. The good selectivity, stability, and rapid response of this sensor suggests that it could have potential applications in long-term non-enzymatic blood glucose monitoring.


Sensors ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 4338 ◽  
Author(s):  
Chengyuan Liu ◽  
Josep Vehí ◽  
Parizad Avari ◽  
Monika Reddy ◽  
Nick Oliver ◽  
...  

(1) Objective: Blood glucose forecasting in type 1 diabetes (T1D) management is a maturing field with numerous algorithms being published and a few of them having reached the commercialisation stage. However, accurate long-term glucose predictions (e.g., >60 min), which are usually needed in applications such as precision insulin dosing (e.g., an artificial pancreas), still remain a challenge. In this paper, we present a novel glucose forecasting algorithm that is well-suited for long-term prediction horizons. The proposed algorithm is currently being used as the core component of a modular safety system for an insulin dose recommender developed within the EU-funded PEPPER (Patient Empowerment through Predictive PERsonalised decision support) project. (2) Methods: The proposed blood glucose forecasting algorithm is based on a compartmental composite model of glucose–insulin dynamics, which uses a deconvolution technique applied to the continuous glucose monitoring (CGM) signal for state estimation. In addition to commonly employed inputs by glucose forecasting methods (i.e., CGM data, insulin, carbohydrates), the proposed algorithm allows the optional input of meal absorption information to enhance prediction accuracy. Clinical data corresponding to 10 adult subjects with T1D were used for evaluation purposes. In addition, in silico data obtained with a modified version of the UVa-Padova simulator was used to further evaluate the impact of accounting for meal absorption information on prediction accuracy. Finally, a comparison with two well-established glucose forecasting algorithms, the autoregressive exogenous (ARX) model and the latent variable-based statistical (LVX) model, was carried out. (3) Results: For prediction horizons beyond 60 min, the performance of the proposed physiological model-based (PM) algorithm is superior to that of the LVX and ARX algorithms. When comparing the performance of PM against the secondly ranked method (ARX) on a 120 min prediction horizon, the percentage improvement on prediction accuracy measured with the root mean square error, A-region of error grid analysis (EGA), and hypoglycaemia prediction calculated by the Matthews correlation coefficient, was 18.8 % , 17.9 % , and 80.9 % , respectively. Although showing a trend towards improvement, the addition of meal absorption information did not provide clinically significant improvements. (4) Conclusion: The proposed glucose forecasting algorithm is potentially well-suited for T1D management applications which require long-term glucose predictions.


Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 260-LB ◽  
Author(s):  
DAVID BAIDAL ◽  
ANA M. ALVAREZ GIL ◽  
NATHALIA PADILLA ◽  
CAMILLO RICORDI ◽  
RODOLFO ALEJANDRO

Diabetes ◽  
2020 ◽  
Vol 69 (Supplement 1) ◽  
pp. 878-P
Author(s):  
KATHERINE TWEDEN ◽  
SAMANWOY GHOSH-DASTIDAR ◽  
ANDREW D. DEHENNIS ◽  
FRANCINE KAUFMAN

Author(s):  
Li-Nong Ji ◽  
Li-Xin Guo ◽  
Li-Bin Liu

AbstractBlood glucose self-monitoring by individuals with diabetes is essential in controlling blood glucose levels. The International Organization for Standardization (ISO) introduced new standards for blood glucose monitoring systems (BGMS) in 2013 (ISO 15197: 2013). The CONTOUR PLUSThis study evaluated the accuracy and precision of CONTOUR PLUS BGMS in quantitative glucose testing of capillary and venous whole blood samples obtained from 363 patients at three different hospitals.Results of fingertip and venous blood glucose measurements by the CONTOUR PLUS system were compared with laboratory reference values to determine accuracy. Accuracy was 98.1% (96.06%–99.22%) for fingertip blood tests and 98.1% (96.02%–99.21%) for venous blood tests. Precision was evaluated across a wide range of blood glucose values (5.1–17.2 mmol/L), testing three blood samples repeatedly 15 times with the CONTOUR PLUS blood glucose meter using test strips from three lots. All within-lot results met ISO criteria (i.e., SD<0.42 mmol/L for blood glucose concentration <5.55 mmol/L; CV<7.5% for blood glucose concentration ≥5.55 mmol/L). Between-lot variations were 1.5% for low blood glucose concentration, 2.4% for normal and 3.4% for high.Accuracy of both fingertip and venous blood glucose measurements by the CONTOUR PLUS system was >95%, confirming that the system meets ISO 15197: 2013 requirements.


2011 ◽  
Vol 5 (6) ◽  
pp. 1472-1479 ◽  
Author(s):  
Jenny Anderson ◽  
Stig Attvall ◽  
Lennart Sternemalm ◽  
Aldina Pivodic ◽  
Martin Fahlén ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document