scholarly journals A Correction Method of Mixed Pesticide Content Prediction in Apple by Using Raman Spectra

2019 ◽  
Vol 9 (8) ◽  
pp. 1699 ◽  
Author(s):  
Li ◽  
Peng ◽  
Qin ◽  
Chao

In the study, a new correction method was applied to reduce error during Raman spectral detection on mixed pesticide residue in apples. Combined with self-built pesticide residues detection system by Raman spectroscopy and the application of surface enhancement technology, rapid real-time qualitative and quantitative analysis of deltamethrin and acetamiprid residues in apples could be applied effectively. In quantitative analysis, compared with the intensity value of characteristic peaks of single pesticide with same concentration, the intensity value of characteristic peaks of the two pesticides decreased after mixing the pesticides, which affected the results severely. By comparing the difference in the intensity of characteristic peaks of single and mixed pesticides, a correction method was proposed to eliminate the influence of pesticides mixture. Characteristic peak intensity values of gradient concentration pesticide from 100 mg·kg−1 to 10−3 mg·kg−1 and Lagrangian interpolation were applied in the correction method. And a smooth surface was applied to describe the correction coefficient of characteristic peak intensity. Through detecting the characteristic peak intensity values of the mixed pesticide, correction coefficient would be obtained. Then real values of the peak intensity of pesticides and the content of each component of the mixed pesticide would be acquired by the correction method. Correlation coefficient of model validation exceeded 0.88 generally and Root Mean Square Error also decreased obviously after correction, which proved the reliability of the method.

Author(s):  
Yan Li ◽  
Yankun Peng ◽  
Jianwei Qin ◽  
Kuanglin Chao

In the study, a new correction method was applied to reduce error during detection on mixed pesticide residue in apples by using Raman spectra. Combined with self-built pesticide residues detection system by Raman spectroscopy and the application of surface enhancement technology, rapid real-time qualitative and quantitative analysis of deltamethrin and acetamiprid residues in apples can be applied effectively. In quantitative analysis, compared with the intensity value of characteristic peaks of single pesticide with same concentration, the intensity value of characteristic peaks of the two pesticides decreased after mixing the pesticides, which interferes the results severely. By comparing the difference in the intensity of characteristic peaks of single and mixed pesticides, a correction method is proposed to eliminate the influence of pesticides mixture. Characteristic peak intensity values of gradient concentration pesticide from 10-1 g•kg-1 to 10-6 g•kg-1 and Lagrangian interpolation are applied in the correction method. And a smooth surface is applied to describe the correction ratio of characteristic peak intensity. Through detecting the characteristic peak intensity values of the mixed pesticide, correction ratio will be obtained. Then real values of the peak intensity of pesticides and the content of each component of the mixed pesticide will be acquired by the correction method. Correlation coefficient of model validation exceeds 0.88 generally and Root Mean Square Error also decreases obviously after correction, which proved the reliability of the method.


2020 ◽  
Vol 2020 ◽  
pp. 1-7 ◽  
Author(s):  
Lvming Chen ◽  
Chaoqun Ma ◽  
Lei Li ◽  
Chun Zhu ◽  
Jiao Gu ◽  
...  

Surface-enhanced Raman spectroscopy (SERS) was used to simply and sensitively detect the artificial sweetener aspartame added to purified water. In this paper, a cavity formed spontaneously by silver ion droplets, and liquid polydimethylsiloxane (PDMS) is used as an SERS substrate to integrate plasma nanoparticles into optical devices. Firstly, Raman spectral characteristics of aspartame powder and aspartame aqueous solution were analyzed. Secondly, the effect of aspartame content in purified water on SERS intensity was investigated by using the prepared PDMS plasma cavity to test the samples. Thirdly, the SERS calibration curve was established by using the characteristic peak intensity of aspartame, and a good linearity relationship between the concentration of aspartame added in purified water and the characteristic peak intensity of 1588(±5) cm-1 was obtained. The linear regression equation and correlation coefficient (r) were y = 11412.73874 x + 107.36722 and 0.99593, respectively. The average recovery of aspartame in purified water was 101–106%, and the relative standard deviation (RSD) was 0.121–0.496%. The experimental results show that using this method can detect aspartame in purified water correctly, which is expected to be used in the identification and detection of sweeteners in purified water.


Author(s):  
K. Li ◽  
Z. Li ◽  
D. Li ◽  
Y. Xie ◽  
H. Xu

Aerosol is an important part of the earth-atmosphere system. It can directly and indirectly influence solar radiation and then affect the energy balance of earth-atmosphere system. AERONET, as the largest ground-based observation network, provides multi-parameters of aerosol from more than 600 hundred sites using sun-sky radiometer, which contains 9 channels from 340&amp;thinsp;nm to 1640&amp;thinsp;nm. Among which, 1020&amp;thinsp;nm channel is greatly influenced by the temperature.<br> In this paper, a new correction method of 1020&amp;thinsp;nm band is introduced. The new method transfers the temperature correction coefficient of the master radiometer to the comparative one. The filed calibration experiment shown that the temperature correction coefficient obtained by this method is close to the result from the temperature controlled chamber, and the difference is about 2.1&amp;thinsp;%. This new method is easy-to-use, and its accuracy is comparable to the standard one. It is more applicable for large-scale instrument calibration. In principle, this method is applicable to all bands of the sun-sky radiometer.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2797
Author(s):  
Jing-Jhong Gao ◽  
Ching-Wei Chiu ◽  
Kuo-Hsing Wen ◽  
Cheng-Sheng Huang

This paper presents a compact spectral detection system for common fluorescent and colorimetric assays. This system includes a gradient grating period guided-mode resonance (GGP-GMR) filter and charge-coupled device. In its current form, the GGP-GMR filter, which has a size of less than 2.5 mm, can achieve a spectral detection range of 500–700 nm. Through the direct measurement of the fluorescence emission, the proposed system was demonstrated to detect both the peak wavelength and its corresponding intensity. One fluorescent assay (albumin) and two colorimetric assays (albumin and creatinine) were performed to demonstrate the practical application of the proposed system for quantifying common liquid assays. The results of our system exhibited suitable agreement with those of a commercial spectrometer in terms of the assay sensitivity and limit of detection (LOD). With the proposed system, the fluorescent albumin, colorimetric albumin, and colorimetric creatinine assays achieved LODs of 40.99 and 398 and 25.49 mg/L, respectively. For a wide selection of biomolecules in point-of-care applications, the spectral detection range achieved by the GGP-GMR filter can be further extended and the simple and compact optical path configuration can be integrated with a lab-on-a-chip system.


2013 ◽  
Vol 26 (21) ◽  
pp. 8597-8615 ◽  
Author(s):  
Alexander Sen Gupta ◽  
Nicolas C. Jourdain ◽  
Jaclyn N. Brown ◽  
Didier Monselesan

Abstract Climate models often exhibit spurious long-term changes independent of either internal variability or changes to external forcing. Such changes, referred to as model “drift,” may distort the estimate of forced change in transient climate simulations. The importance of drift is examined in comparison to historical trends over recent decades in the Coupled Model Intercomparison Project (CMIP). Comparison based on a selection of metrics suggests a significant overall reduction in the magnitude of drift from phase 3 of CMIP (CMIP3) to phase 5 of CMIP (CMIP5). The direction of both ocean and atmospheric drift is systematically biased in some models introducing statistically significant drift in globally averaged metrics. Nevertheless, for most models globally averaged drift remains weak compared to the associated forced trends and is often smaller than the difference between trends derived from different ensemble members or the error introduced by the aliasing of natural variability. An exception to this is metrics that include the deep ocean (e.g., steric sea level) where drift can dominate in forced simulations. In such circumstances drift must be corrected for using information from concurrent control experiments. Many CMIP5 models now include ocean biogeochemistry. Like physical models, biogeochemical models generally undergo long spinup integrations to minimize drift. Nevertheless, based on a limited subset of models, it is found that drift is an important consideration and must be accounted for. For properties or regions where drift is important, the drift correction method must be carefully considered. The use of a drift estimate based on the full control time series is recommended to minimize the contamination of the drift estimate by internal variability.


2014 ◽  
Vol 1061-1062 ◽  
pp. 1144-1147
Author(s):  
Jun Fu ◽  
Jin Zhao Wu ◽  
Ning Zhou ◽  
Hong Yan Tan

We present a quantitative model, called metric hybrid automata, for quantifying the behaviors of complex physical systems, such as chemical reaction control systems, manufacturing systems etc. Due to the introduction of a metric, the state space of hybrid automata forms a metric space, in which the difference of states can be quantified. Furthermore, in order to reveal the distance of system behaviors, we construct the simulation distance and the bisimulation distance, which quantify the similarity of system behaviors. Our model provides the basis for quantitative analysis for those complex physical systems.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3917
Author(s):  
Jong-Dae Kim ◽  
Chan-Young Park ◽  
Yu-Seop Kim ◽  
Ji-Soo Hwang

Most existing commercial real-time polymerase chain reaction (RT-PCR) instruments are bulky because they contain expensive fluorescent detection sensors or complex optical structures. In this paper, we propose an RT-PCR system using a camera module for smartphones that is an ultra small, high-performance and low-cost sensor for fluorescence detection. The proposed system provides stable DNA amplification. A quantitative analysis of fluorescence intensity changes shows the camera’s performance compared with that of commercial instruments. Changes in the performance between the experiments and the sets were also observed based on the threshold cycle values in a commercial RT-PCR system. The overall difference in the measured threshold cycles between the commercial system and the proposed camera was only 0.76 cycles, verifying the performance of the proposed system. The set calibration even reduced the difference to 0.41 cycles, which was less than the experimental variation in the commercial system, and there was no difference in performance.


2021 ◽  
Author(s):  
Ya-Dong Gao ◽  
De-Dong He ◽  
Ke Gong ◽  
Guang-Yu Shi ◽  
Si-Yuan Chen ◽  
...  

Abstract A prompt gamma neutron activation analysis (PGNAA) system based on a deuterium-deuterium (D-D) sealed neutron generator was designed using the MOCA code for explosive detection. The system is mainly composed of four parts: D-D sealed neutron generator, moderator, shielding, and Lutetium Yttrium OxyorthoSilicate (LYSO) scintillation detectors. Polyethylene (PE) was selected as the moderator and the optimal thickness was 7cm. Lead, PE, and boron-containing polyethylene were used as shielding materials. In the optimized model, the LYSO detector is used to measure eighteen materials, such as wood, melamine, glucose, and nylon, and so on. Firstly, the nitrogen characteristic peak of 10.8 MeV was analyzed to determine whether the material contained nitrogen. Then, the ratio of characteristic peak counts of C/O and O/N were calculated to distinguish explosives from nitrogen containing materials. Finally, dinitrobenzene, nitroglycerin, TNT, and ammonium nitrate can be separated from nitrogenous substances by a discriminant algorithm. The final device can be used to detect the chemical composition of the threat substances, and the maximum dose rate of the system meets the limits of international protection standards.


2013 ◽  
Vol 473 ◽  
pp. 231-234
Author(s):  
Su Hua Chen ◽  
Xu Fang ◽  
Yong Guang Liu ◽  
Jun Wang

The design attempts for thefirst time to realize face locating system on the FPGA platform using themethod combined initiative infrared source with image difference. Through imagedifference process, the system obtains a difference image without backgroundinterference which takes the face as the main body. It can obtain the personface boundary by projecting the difference image in the horizontal and verticaldirection. The system processing speed amount s to the video source frequency25 frame per second, satisfying the timely request; the method of initiativeinfrared source makes the exterior have small influence on the image andguarantees the robustness of the system.


2004 ◽  
Vol 37 (3) ◽  
pp. 438-444 ◽  
Author(s):  
Florian Nettesheim ◽  
Ulf Olsson ◽  
Peter Lindner ◽  
Walter Richtering

A method of correcting the asymmetry in the scattering of the tangential beam configuration in a rheo-small-angle neutron scattering experiment is proposed. The asymmetry of the scattering in the tangential beam configuration can be attributed to the difference in pathlength for neutrons that are scattered toward compared with those which are scattered away from the axis of rotation of the shear cell. The pathlength problem is solved and a final expression for the two-dimensional scattering intensity is given. The results from these calculations are compared with experimental data, which offer a different option to correct this asymmetry, namely by just measuring the scattering of H2O/D2O mixtures with absolute scattering cross sections identical to those of the respective samples. However, the situation for anisotropic media is more complex and the correction procedure described here is less effective.