scholarly journals Multi-Perspective Ultrasound Imaging Technology of the Breast with Cylindrical Motion of Linear Arrays

2019 ◽  
Vol 9 (3) ◽  
pp. 419 ◽  
Author(s):  
Chang Liu ◽  
Binzhen Zhang ◽  
Chenyang Xue ◽  
Wendong Zhang ◽  
Guojun Zhang ◽  
...  

In this paper, we propose a multi-perspective ultrasound imaging technology with the cylindrical motion of four piezoelectric micromachined ultrasonic transducer (PMUT) rotatable linear arrays. The transducer is configured in a cross shape vertically on the circle with the length of the arrays parallel to the z axis, roughly perpendicular to the chest wall. The transducers surrounded the breast, which achieves non-invasive detection. The electric rotary table drives the PMUT to perform cylindrical scanning. A breast model with a 2 cm mass in the center and six 1-cm superficial masses were used for the experimental analysis. The detection was carried out in a water tank and the working temperature was constant at 32 °C. The breast volume data were acquired by rotating the probe 90° with a 2° interval, which were 256 × 180 A-scan lines. The optimized segmented dynamic focusing technology was used to improve the image quality and data reconstruction was performed. A total of 256 A-scan lines at a constant angle were recombined and 180 A-scan lines were recombined according to the nth element as a dataset, respectively. Combined with ultrasound imaging algorithms, multi-perspective ultrasound imaging was realized including vertical slices, horizontal slices and 3D imaging. The seven masses were detected and the absolute error of the size was approximately 1 mm where even the image of the injection pinhole could be seen. Furthermore, the breast boundary could be seen clearly from the chest wall to the nipple, so the location of the masses was easier to confirm. Therefore, the validity and feasibility of the data reconstruction method and imaging algorithm were verified. It will be beneficial for doctors to be able to comprehensively observe the pathological tissue.

Author(s):  
Yuanyu Yu ◽  
Jiujiang Wang ◽  
Xin Liu ◽  
Sio Hang Pun ◽  
Weibao Qiu ◽  
...  

Background:: Ultrasound is widely used in the applications of underwater imaging. Capacitive micromachined ultrasonic transducer (CMUT) is a promising candidate to the traditional piezoelectric ultrasonic transducer. In underwater ultrasound imaging, better resolutions can be achieved with a higher frequency ultrasound. Therefore, a CMUT array for high-frequency ultrasound imaging is proposed in this work. Methods:: Analytical methods are used to calculate the center frequency in water and the pull-in voltage for determining the operating point of CMUT. Finite element method model was developed to finalize the design parameters. The CMUT array was fabricated with a five-mask sacrificial release process. Results:: The CMUT array owned an immersed center frequency of 2.6 MHz with a 6 dB fractional bandwidth of 123 %. The pull-in voltage of the CMUT array was 85 V. An underwater imaging experiment was carried out with the target of three steel wires. Conclusion:: In this study, we have developed CMUT for high-frequency underwater imaging. The experiment showed that the CMUT can detect the steel wires with the diameter of 100 μm and the axial resolution was 0.582 mm, which is close to one wavelength of ultrasound in 2.6 MHz.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 640
Author(s):  
Yujia Tang ◽  
Zhangjian Li ◽  
Yaoyao Cui ◽  
Chen Yang ◽  
Jiabing Lv ◽  
...  

Ultrasound plane wave imaging technology has been applied to more clinical situations than ever before because of its rapid imaging speed and stable imaging quality. Most transducers used in plane wave imaging are linear arrays, but their structures limit the application of plane wave imaging technology in some special clinical situations, especially in the endoscopic environment. In the endoscopic environment, the size of the linear array transducer is strictly miniaturized, and the imaging range is also limited to the near field. Meanwhile, the near field of a micro linear array has serious mutual interferences between elements, which is against the imaging quality of near field. Therefore, we propose a new structure of a micro ultrasound linear array for plane wave imaging. In this paper, a theoretical comparison is given through sound field and imaging simulations. On the basis of primary work and laboratory technology, micro uniform and non-uniform linear arrays were made and experimented with the phantom setting. We selected appropriate evaluation parameters to verify the imaging results. Finally, we concluded that the micro non-uniform linear array eliminated the artifacts better than the micro uniform linear array without the additional use of signal processing methods, especially for target points in the near-field. We believe this study provides a possible solution for plane wave imaging in cramped environments like endoscopy.


Sensors ◽  
2019 ◽  
Vol 19 (9) ◽  
pp. 2138 ◽  
Author(s):  
Hossam Selim ◽  
José Trull ◽  
Miguel Delgado Prieto ◽  
Rubén Picó ◽  
Luis Romeral ◽  
...  

Nondestructive testing of metallic objects that may contain embedded defects of different sizes is an important application in many industrial branches for quality control. Most of these techniques allow defect detection and its approximate localization, but few methods give enough information for its 3D reconstruction. Here we present a hybrid laser–transducer system that combines remote, laser-generated ultrasound excitation and noncontact ultrasonic transducer detection. This fully noncontact method allows access to scan areas on different object’s faces and defect details from different angles/perspectives. This hybrid system can analyze the object’s volume data and allows a 3D reconstruction image of the embedded defects. As a novelty for signal processing improvement, we use a 2D apodization window filtering technique, applied along with the synthetic aperture focusing algorithm, to remove the undesired effects due to side lobes and wide-angle reflections of propagating ultrasound waves, thus enhancing the resulting 3D image of the defect. Finally, we provide both qualitative and quantitative volumetric results that yield valuable information about defect location and size.


Geophysics ◽  
2019 ◽  
Vol 84 (6) ◽  
pp. G83-G92
Author(s):  
Ya Xu ◽  
Fangzhou Nan ◽  
Weiping Cao ◽  
Song Huang ◽  
Tianyao Hao

Irregular sampled gravity data are often interpolated into regular grid data for convenience of data processing and interpretation. The compressed sensing theory provides a signal reconstruction method that can recover a sparse signal from far fewer samples. We have introduced a gravity data reconstruction method based on the nonequispaced Fourier transform (NFT) in the framework of compressed sensing theory. We have developed a sparsity analysis and a reconstruction algorithm with an iterative cooling thresholding method and applied to the gravity data of the Bishop model. For 2D data reconstruction, we use two methods to build the weighting factors: the Gaussian function and the Voronoi method. Both have good reconstruction results from the 2D data tests. The 2D reconstruction tests from different sampling rates and comparison with the minimum curvature and the kriging methods indicate that the reconstruction method based on the NFT has a good reconstruction result even with few sampling data.


2014 ◽  
Vol 556-562 ◽  
pp. 4317-4320
Author(s):  
Qiang Zhang ◽  
Li Ping Liu ◽  
Chao Liu

As a zero-emission mode of transportation, an increasing number of Electric Vehicles (EV) have come into use in our daily lives. The EV charging station is an important component of the Smart Grid which is now facing the challenges of big data. This paper presents a data compression and reconstruction method based on the technique of Principal Component Analysis (PCA). The data reconstruction error Normalized Absolute Percent Error (NAPE) is taken into consideration to balance the compression ratio and data reconstruction quality. By using the simulated data, the effectiveness of data compression and reconstruction for EV charging stations are verified.


Sign in / Sign up

Export Citation Format

Share Document