scholarly journals Analyses of the Effect of Cycle Inlet Temperature on the Precooler and Plant Efficiency of the Simple and Intercooled Helium Gas Turbine Cycles for Generation IV Nuclear Power Plants

2017 ◽  
Vol 7 (4) ◽  
pp. 319 ◽  
Author(s):  
Arnold Gad-Briggs ◽  
Theoklis Nikolaidis ◽  
Pericles Pilidis
Author(s):  
Arnold Gad-Briggs ◽  
Pericles Pilidis ◽  
Theoklis Nikolaidis

Studies are currently on-going on the cycle performance of Generation IV (Gen IV) Nuclear Power Plants (NPPs) for the purpose of determining optimum operating conditions for efficiency and economic reasons. For Gas-cooled Fast Reactors (GFRs) and Very-High Temperature Reactors (VHTRs), the cycle layout is predominantly driven by the choice of components, the component configuration and the coolant. The purpose of this paper to present and review the cycles currently being considered — the Simple Cycle Recuperated (SCR) and the Intercooled Cycle Recuperated (ICR). In all cases, the cycles utilise helium as the coolant in a closed Brayton gas turbine configuration. Comparisons between the cycles are made for Design Point (DP) and Off-Design Point (ODP) analyses to emphasise the benefits and drawbacks of each cycle. The paper also talks about future trends which include higher Core Outlet Temperatures in excess of 1000 degrees Celsius and the proposal of a simplified cycle configuration which eliminates the need for the recuperator.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Arnold Gad-Briggs ◽  
Emmanuel Osigwe ◽  
Pericles Pilidis ◽  
Theoklis Nikolaidis ◽  
Suresh Sampath ◽  
...  

Abstract Numerous studies are on-going on to understand the performance of generation IV (Gen IV) nuclear power plants (NPPs). The objective is to determine optimum operating conditions for efficiency and economic reasons in line with the goals of Gen IV. For Gen IV concepts such as the gas-cooled fast reactors (GFRs) and very-high temperature reactors (VHTRs), the choice of cycle configuration is influenced by component choices, the component configuration and the choice of coolant. The purpose of this paper to present and review current cycles being considered—the simple cycle recuperated (SCR) and the intercooled cycle recuperated (ICR). For both cycles, helium is considered as the coolant in a closed Brayton gas turbine configuration. Comparisons are made for design point (DP) and off-design point (ODP) analyses to emphasize the pros and cons of each cycle. This paper also discusses potential future trends, include higher reactor core outlet temperatures (COT) in excess of 1000 °C and the simplified cycle configurations.


1979 ◽  
Vol 101 (1) ◽  
pp. 130-140 ◽  
Author(s):  
Z. P. Tilliette ◽  
B. Pierre ◽  
P. F. Jude

The advantages of gas turbine power plants in general and closed cycle systems under gas pressure in particular for waste heat recovery are well known. A satisfactory efficiency for electric power generation and good conditions to obtain a significant amount of hot water above 100°C lead to a high fuel utilization. However, as in most of projects, it is not much possible to produce high temperature steam or water without significantly decreasing the electricity production. A new method for an additional generation of high quality process or domestic heat is proposed. The basic feature of this method lies in arranging one or two steam generators or preheaters in parallel with the low pressure side of the recuperator. The high total efficiency and the noteworthy flexibility of this system are emphasized. This arrangement is suitable for any kind of heat source, but the applications presented in this paper are related to helium direct cycle nuclear power plants the main features of which are a single 600 MW(e) turbomachine, a turbine inlet temperature of 775°C, no or one intermediate cooling and a primary circuit fully integrated in a pre-stressed concrete reactor vessel.


Author(s):  
Arnold Gad-Briggs ◽  
Pericles Pilidis ◽  
Theoklis Nikolaidis

A framework – NuTERA (Nuclear Techno-Economic and Risk Assessment) has been developed to set out the requirements for evaluating Generation IV (Gen IV) Nuclear Power Plants (NPPs) at the design conceptual stage. The purpose of the framework is to provide guidelines for future tools that are required to support the decision-making process on the choice of Gen IV concepts and cycle configurations. In this paper, the underpinning of the framework has been demonstrated to enable the creation of an analyses tool, which evaluates the design of an NPP that utilises helium closed Brayton gas turbine cycles. The tool at the broad spectrum focuses on the component and cycle design, Design Point (DP) and Off-Design Point (ODP) performance, part power and load following operations. Specifically, the design model has been created to provide functionalities that look at the in-depth sensitivities of the design factors and operation that affect the efficiency of an NPP such as temperature and pressure ratios, inlet cycle temperatures, component efficiencies, pressure losses. The ODP performance capabilities include newly derived component maps for the reactor, intercooler and recuperator for long term Off-Design (OD) operation. With regard to short term OD, which is typically driven by changes in ambient conditions, the ability to analyse the cycle load following capabilities are possible. An economic model has also been created, which calculates the component costs and the baseline economic evaluation. An incorporated risk model quantifies the performance, operational, financial and design impact risks. However, the tool is able to optimise the NPP cycle configuration based on the best economics using the Levelised Unit Electricity Cost (LUEC) as a measure. The tool has been used to demonstrate a typical decision-making process on 2 Gen IV helium closed gas turbine cycles, which apply to the Gas-cooled Fast Reactors (GFRs) and Very-High Temperature Reactors (VHTRs). The cycles are the Simple Cycle Recuperator (SCR) and Intercooled Cycle Recuperator (ICR). The tool was able to derive the most efficient cycle configurations for the ICR (53% cycle efficiency) and SCR (50% cycle efficiency). Based on these efficiency figures, the baseline LUEC ($/MWh) for the year 2020 is $62.13 for the ICR and $61.84 for the SCR. However, the inclusion of the cost of contingencies due to risks and the subsequent economic optimisation resulted in a cost of $69.70 and $69.80 for the ICR and SCR respectively.


1970 ◽  
Author(s):  
W. Endres

A short review of the state-of-the-art of the closed cycle gas turbine technology is given and the future requirements for large helium turbines are described. The necessary development of components and turbine sizes is outlined. In a second part of the paper the configuration and layout of power plants with gas turbines are discussed.


2018 ◽  
Vol 2 (1) ◽  

The major growth in the electricity production industry in the last 30 years has centered on the expansion of natural gas power plants based on gas turbine cycles. The most popular extension of the simple Brayton gas turbine has been the combined cycle power plant with the Air-Brayton cycle serving as the topping cycle and the Steam-Rankine cycle serving as the bottoming cycle for new generation of nuclear power plants that are known as GEN-IV. The Air-Brayton cycle is an open-air cycle and the Steam-Rankine cycle is a closed cycle. The air-Brayton cycle for a natural gas driven power plant must be an open cycle, where the air is drawn in from the environment and exhausted with the products of combustion to the environment. This technique is suggested as an innovative approach to GEN-IV nuclear power plants in form and type of Small Modular Reactors (SMRs). The hot exhaust from the AirBrayton cycle passes through a Heat Recovery Steam Generator (HSRG) prior to exhausting to the environment in a combined cycle. The HRSG serves the same purpose as a boiler for the conventional Steam-Rankine cycle [1].


2020 ◽  
Vol 6 (2) ◽  
Author(s):  
Emmanuel O. Osigwe ◽  
Arnold Gad-Briggs ◽  
Theoklis Nikolaidis ◽  
Pericles Pilidis ◽  
Suresh Sampath

Abstract A significant hurdle in the development of performance simulation tools to analyze and evaluate nuclear power plants (NPP) is finding data relating to component performance maps. As a result, engineers often rely on an estimation approach using various scaling techniques. The purpose of this study is to determine the component characteristics of a closed-cycle gas turbine NPP using the existing component maps with the corresponding design data. The design data are applied for different working fluids using a multifluid scaling approach to adapt data from one component map into another. The multifluid scaling technique described herein was developed as an in-house computer simulation tool. This approach makes it easy to theoretically scale the existing maps using similar or different working fluids without carrying out a full experimental test or repeating the whole design and development process. The results of selected case studies show a reasonable agreement with the available data. The analyses intend to aid the development of cycles for Generation IV NPPs specifically gas-cooled fast reactors (GFRs) and very high-temperature reactors (VHTRs).


1980 ◽  
Author(s):  
Z. P. Tilliette ◽  
B. Pierre

A now unavoidable concern is the best possible use of a given energy source in order to meet the demand of power and heat. The most efficient, rational, thermodynamically satisfactory way of producing heat is to cogenerate it with power and to handle it as a by-product. Another basic condition is to supply heat without disturbing the operation of main turbogenerators. Closed helium cycle, non-intercooled, gas turbine coal-fired and nuclear power plants which meet these requirements are presented in this paper. Low-pressure steam and hot water are recovered from the precooler; medium, high pressure steam and steam superheating are generated by means of a bypass arrangement of the recuperator. The concept offers attractive overall energy conversion coefficients, very flexible heat production conditions and significant potentialities of reducing oil consumption. Results are given for the conservative 750 C gas turbine inlet temperature.


2019 ◽  
Vol 5 (4) ◽  
Author(s):  
Arnold Gad-Briggs ◽  
Pericles Pilidis ◽  
Theoklis Nikolaidis

The simple cycle recuperated (SCR) and intercooled cycle recuperated (ICR) are highly efficient Brayton helium gas turbine cycles, designed for the gas-cooled fast reactor (GFR) and very-high-temperature reactor (VHTR) generation IV (Gen IV) nuclear power plants (NPPs). This paper documents risk analyses, which consider technical and economic aspects of the NPP. The sensitivity analyses are presented that interrogate the plant design, performance, and operational schedule and range from component efficiencies, system pressure losses, operating at varied power output due to short-term load-following or long-term reduced power operations to prioritize other sources such as renewables. The sensitivities of the economic and construction schedule are also considered in terms of the discount rates, capital and operational costs, and increased costs in decontamination and decommissioning (D&D) activity due to changes in the discount rates. This was made possible by using a tool designed for this study to demonstrate the effect on the “noncontingency” baseline levelized unit electricity cost (LUEC) of both cycles. The SCR with a cycle efficiency of 50% has a cheaper baseline LUEC of $58.41/MWh in comparison to the ICR (53% cycle efficiency), which has an LUEC of $58.70/MWh. However, the cost of the technical and economic risks is cheaper for the ICR resulting in a final LUEC of $70.45/MWh (ICR) in comparison to the SCR ($71.62/MWh) for the year 2020 prices.


1980 ◽  
Author(s):  
P. B. Roberts ◽  
T. E. Duffy ◽  
H. Schreiber

Two combustion turbine combined cycle power plants have been studied for performance and operating economics. Both power plants are in the size range that will be suitable for small utility application and use less than 106 GJ/hr (100 million Btu/hr). The Powerplant and Industrial Fuel Use Act of 1978 has exempted power plants of this size from the requirement to use coal. The first power plant is based on the Solar Turbines International (STI) Mars industrial gas turbine. The combined gas turbine/steam cycle is direct fired with No. 2 diesel fuel. A net plant efficiency of 39.7 percent (HHV) is obtained at the 11.56-mW growth rating of the Mars engine for a turbine rotor inlet temperature of 1331 K (1935 F). A total installed cost for the system is estimated to be within the band 545 to 660 $/kW. The second power plant is based on STI’s Centaur industrial gas turbine. The combined gas turbine/steam cycle is indirectly fired with solid fuel although it is intended that the installation can be initially fired with a liquid fuel. A net plant efficiency of 25.0 percent (HHV) is obtained burning Illinois No. 6 coal at a rating of 3.78 mW with a turbine inlet gas temperature of 1117 K (1550 F).


Sign in / Sign up

Export Citation Format

Share Document