scholarly journals Numerical Model Development of the Air Temperature Variation in a Room Set on Fire for Different Ventilation Scenarios

2021 ◽  
Vol 11 (24) ◽  
pp. 11698
Author(s):  
Marius Dorin Lulea ◽  
Vlad Iordache ◽  
Ilinca Năstase

Statistics show that most fires occur in civil residential buildings. Most casualties are due to the inhalation of hot air loaded with smoke, leading to intoxication with substances harmful to the human body. This research aimed to develop a CFD model that relates the operation of the sprinkler system to the operation of the ventilation system through the air temperature in a specific point close to the sprinkler position. A real-scale experiment was carried out, and a CDF model was developed. Several parameters of the CFD model (thermal conductivity of the experimental test room walls, numerical grid elements’ dimensions, burner heat release rate variation) were imposed to the model, so that the resulting entire time variation of the temperature next to the sprinkler location corresponds to the real measured variation. Two other experiments were used to validate the numerical model. Besides the air temperature, at this point, other essential parameters were determined in the entire experimental space: indoor air temperature, visibility, oxygen concentration, and carbon dioxide concentration. We found that if the ventilation rate increases, the indoor temperatures in that specific point decrease, and the sprinkler is activated later or, in some cases, it might never be activated. However, this conclusion is not valid for the entire analyzed space, as the ventilation system alongside the natural air movement imposes specific air speed and specific temperature distribution inside the analyzed space.

2014 ◽  
Vol 60 (1) ◽  
pp. 91-121
Author(s):  
M. Krzaczek ◽  
J. Tejchman

Abstract The influence of the CO2 concentration in a local air zone in naturally ventilated residential houses on the residents’ behaviour was numerically investigated. A numerical two-dimensional CFD model of the indoor zone based on experiments performed by the authors was used. Different resident locations in the fluid domain and different inlet velocities imposed by wind were considered in simulations. The overall thermal comfort and IAQ indices were also calculated. The investigations results show that in contrast to the overall air quality, the local CO2 was strongly dependent upon the resident location, fresh air inlet velocity and ventilation system type.


2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


1999 ◽  
Vol 39 (9) ◽  
pp. 95-103 ◽  
Author(s):  
S. Djordjević ◽  
D. Prodanović ◽  
Č. Maksimović

The paper presents the development of the field of urban drainage modelling known as dual drainage - an approach to rainfaill runoff simulation in which the numerical model takes into account not only the flow through the sewer system, but also the flow on the surface. The steps in model development are described, and necessary data, assumptions used and operations to be performed using GIS are discussed. The numerical model simultaneously handles the full dynamic equations of flow through the sewer system and simplified equations of the surface flow. The surface excess water (due to the limited capacity of inlets or to the hydraulic head in the sewer system reaching the ground level) is routed to the neighbour subcatchment (not necessarily the one attached to the downstream network node), using surface retentions, if any.


Author(s):  
Yuri Vassilevski ◽  
Kirill Terekhov ◽  
Kirill Nikitin ◽  
Ivan Kapyrin

2013 ◽  
Vol 1 (4) ◽  
pp. 3485-3527 ◽  
Author(s):  
H. Cammerer ◽  
A. H. Thieken ◽  
J. Lammel

Abstract. Flood loss modeling is an important component within flood risk assessments. Traditionally, stage-damage functions are used for the estimation of direct monetary damage to buildings. Although it is known that such functions are governed by large uncertainties, they are commonly applied – even in different geographical regions – without further validation, mainly due to the lack of data. Until now, little research has been done to investigate the applicability and transferability of such damage models to other regions. In this study, the last severe flood event in the Austrian Lech Valley in 2005 was simulated to test the performance of various damage functions for the residential sector. In addition to common stage-damage curves, new functions were derived from empirical flood loss data collected in the aftermath of recent flood events in the neighboring Germany. Furthermore, a multi-parameter flood loss model for the residential sector was adapted to the study area and also evaluated by official damage data. The analysis reveals that flood loss functions derived from related and homogenous regions perform considerably better than those from more heterogeneous datasets. To illustrate the effect of model choice on the resulting uncertainty of damage estimates, the current flood risk for residential areas was assessed. In case of extreme events like the 300 yr flood, for example, the range of losses to residential buildings between the highest and the lowest estimates amounts to a factor of 18, in contrast to properly validated models with a factor of 2.3. Even if the risk analysis is only performed for residential areas, more attention should be paid to flood loss assessments in future. To increase the reliability of damage modeling, more loss data for model development and validation are needed.


Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.


2021 ◽  
Vol 61 (3) ◽  
pp. 476-488
Author(s):  
Tomáš Suk ◽  
Martin Štroner

This paper presents the results of over a year-long experiment dealing with a temperature measurement to calculate the theoretical effect of the atmosphere on the measured zenith angle in engineering surveying. The measurements were performed to determine the accurate and specific temperatures (temperature gradients), which can be recorded in different seasons in the low level of the atmosphere (up to 2 m above the ground, where most Engineering Surveying measurements take place) for the geographical area of Central Europe - specifically the Czech Republic. A numerical model was then applied to the resulting determined temperature gradients to calculate the path of the beam passing through an inhomogeneous atmosphere. From these values, the apparent vertical shifts caused by refraction in a given environment and time were finally determined.


Sign in / Sign up

Export Citation Format

Share Document