scholarly journals Lightning Surge Analysis for Overhead Lines Considering Corona Effect

2021 ◽  
Vol 11 (19) ◽  
pp. 8942
Author(s):  
Xiaoqing Zhang ◽  
Kejie Huang

Corona discharge characteristics are measured in a corona cage. The difference is found between the q–u curves under double exponential and damped oscillation surges. The behavior of the minor loops is revealed for the q–u curves under positive and negative damped oscillation surges. An extended improvement is made on the traditional approach for modeling of the q–u curves under damped oscillation surges. The extended approach has the capability of describing the complicated trajectory feature of the minor loops. On the basis of the extended approach, an efficient method is proposed for performing lightning surge analysis of overhead lines considering the corona effect. In the proposed method, an overhead line with corona is divided into a certain number of line segments. Each segment is converted into a circuit unit consisting of a non-linear branch and a linear circuit. With these circuit units connected in sequence, a complete equivalent circuit is constructed for the overhead line with corona. The transient responses can be obtained from the solution to the equivalent circuit. Then, the calculated results are compared with the field test results on a test overhead line.

Author(s):  
Svetlana Guseva ◽  
Lubov Petrichenko

The choice of optimum cross section for overhead line by economic intervals' methodIn this paper an approach to choosing the optimum cross section for overhead line in conditions of incomplete and uncertain information is considered. The two methods of such choice are presented: method of economic current density and economic intervals' method. The correction of the economic intervals method is offered under market conditions of costs. As example 20 kV and 110 kV overhead lines with aluminum, copper and ferroaluminum wires are selected. Universal nomograms with different standard cross section are calculated and constructed. The graphics using Mathcad software are offered.


2021 ◽  
Vol 5 (2) ◽  
pp. 51
Author(s):  
Zongze Li ◽  
Hiroki Ogata ◽  
Ryuta Sato ◽  
Keiichi Shirase ◽  
Shigehiko Sakamoto

A cubic-machining test has been proposed to evaluate the geometric errors of rotary axes in five-axis machine tools using a 3 × 3 zone area in the same plane with different tool postures. However, as only the height deviation among the machining zones is detected by evaluating the test results, the machining test results are expected to be affected by some error parameters of tool sides, such as tool length and profile errors, and there is no research investigation on how the tool side error influences the cubic-machining test accuracy. In this study, machining inaccuracies caused by tool length and tool profile errors were investigated. The machining error caused by tool length error was formulated, and an intentional tool length error was introduced in the simulations and actual machining tests. As a result, the formulated and simulated influence of tool length error agreed with the actual machining results. Moreover, it was confirmed that the difference between the simulation result and the actual machining result can be explained by the influence of the tool profile error. This indicates that the accuracy of the cubic-machining test is directly affected by tool side errors.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3830
Author(s):  
Shicheng Sun ◽  
Chuanxin Rong ◽  
Hua Cheng ◽  
Bin Wang ◽  
Xiaogang Jiang ◽  
...  

Groundwater velocity has significant effects on the formation of a frozen curtain during freezing. In order to study the influence of the velocity on a frozen curtain, a large physical model test platform was established for double-pipe freezing. Based on this platform, freezing tests for different velocities were carried out. Quartz sand was selected as a similar material. The freezing temperature of the saturated sand layer was found by analyzing the results of the nuclear magnetic resonance (NMR). Based on the study of the thermal physical properties of the sand layer, the freezing test results were analyzed, and the results showed that the flow led to the differential development of the temperature between the upstream and downstream sections of the freezing pipes. Moreover, the larger the velocity, the greater the difference. The flow prolonged the overlapping time of the frozen curtains. Additionally, the flow slowed down the development of the frozen curtain area and the frozen curtain thickness. The larger the flow velocity, the greater the inhibition of the flow on the development of the frozen curtain. The test results can provide more references for the design and construction of freezing engineering with flowing groundwater.


2007 ◽  
Vol 330-332 ◽  
pp. 495-498
Author(s):  
Chao Zou ◽  
Wen Jian Weng ◽  
Xu Liang Deng ◽  
Kui Cheng ◽  
Pi Yi Du ◽  
...  

Two starting collagens, sponge and floc collagen, were used to prepare collagen/tricalcium phosphate (TCP) composites. The resulting composites were porous and had 200μm pore size. However, there was a difference in the microstructure of the pore walls for the composites derived from the two collagens, the pore walls in sponge collagen/TCP composite were still porous and had 200 nm micropores size, TCP particles were trapped in collagen matrices. While floc collagen/TCP composite had smooth and dense walls in which TCP particles were embedded. The difference could be attributed to the starting collagen with different status. Sponge collagen has a soft structure, which easily becomes disassembled fibrils during alkali treatment, the disassembled fibrils are integrated again to form a dense morphology for pore walls after freeze-drying. While floc collagen has already a low disassembly degree, the alkali treatment could not be able to separate the fibrils, this remains as micropores in pore walls after freeze-drying. Both porous composites are significant in bone tissue engineering or regeneration. MTT test results showed the two composites had good cytocompatibility, and sponge collagen/TCP composite was somewhat better than floc collagen/TCP composite, which could result from that micropores derived roughness in pore walls of sponge collagen/TCP composite is suitable for cell growth.


2013 ◽  
Vol 325-326 ◽  
pp. 590-593
Author(s):  
Fei Xiang Wei ◽  
Yang Song ◽  
Xiao Xu Ma ◽  
Ying Qian

The transmission line is an important part of the power system, its reliability will directly affect the reliability of the power system. The reliability of the overhead line plays a crucial role for the power system reliability. This paper analyze the reasons of the falling of the overhead lines, establish a fault tree, and make qualitative and quantitative analysis of the fault tree.


1992 ◽  
Vol 7 (7) ◽  
pp. 1959-1960
Author(s):  
Hu Gengxiang ◽  
Chen Shipu ◽  
Wu Xiaohua ◽  
Chen Xiaofu

Compression test results of our research on Al3Ti-base alloys are reported. It is evident that the specimen length-to-width ratio we used for compression testing can significantly reflect the difference in ductility of different alloys. Thus the tests fulfilled the aim of our present research.


Author(s):  
Agostino Marioni ◽  
Roberto Dalpedri ◽  
Marco Banfi ◽  
Carla Cai

<p>The Padma Bridge is a multipurpose road-rail bridge across the Padma River currently under construction in Bangladesh and is one of the most important projects in the whole south east Asia with a total length of 6150 m. The maximum design vertical load reaches 98725 kN.</p><p>The Holtekamp Bridge is a steel road bridge with 2 main spans of 150 m and 2 lateral spans of 75 for a total length of 450 m. The bridge is isolated by use of sliding pendulum isolators having a maximum vertical load capacity at ULS of 54915 kN.</p><p>In both cases the isolators are double sliding surface type but with a different approach about the central articulation. The paper aims to put in evidence the difference in behaviour of the 2 types of pendulum, analysing both the theoretical approach and the test results with a special focus over the adopted solution for perform the test on a device which exceed the capacity of aby existing laboratory.</p>


Author(s):  
Djoen San Santoso ◽  
Nuttapon Bourpanus

Purpose This study aims to examine the influences of shifting the bidding system of Thai public infrastructure projects from e-auction to e-bidding. Design/methodology/approach A questionnaire survey was conducted with owners or senior managers with direct responsibility in deciding the mark-up of 72 small and medium-sized contractor firms. Five senior professionals were interviewed to provide insights into and to strengthen the discussion of the findings. The Wilcoxon test was applied to analyze the difference in the importance of the factors between e-auction and e-bidding. Findings The results revealed a shift in the importance of the factors, from those related to the financial aspects in the e-auction to the situational aspects in the e-bidding. The comparison test results also suggested that the majority of factors become significantly less important in the e-bidding system, with “identity of competitors” and “general expense of the bidding process” having the most apparent mean differences. The interview results supported by data on winning prices and estimations strongly indicated that bid collusions likely exist in the e-auction. By shifting to e-bidding, the data also show that the Thai Government can save public money in its infrastructure project development. Originality/value The study provides an analysis from the perspectives of contractor firms on how e-auction and e-bidding options influence bid mark-up decisions. Many studies have focused on the issues and advantages provided by the e-procurement mainly from the owner (government)’s perspective but how the change influences the contractor’s attitude has been less explored.


Sign in / Sign up

Export Citation Format

Share Document