scholarly journals Prevention of Mandible Fractures in Medication-Related Osteonecrosis of the Jaws: The Role of Virtual Surgical Planning and Computer-Aided Design and Manufacturing in Two Clinical Case Reports

2021 ◽  
Vol 11 (17) ◽  
pp. 7894
Author(s):  
João André Correia ◽  
José Ricardo Ferreira ◽  
Miguel Amaral Nunes ◽  
António Capelo ◽  
Miguel de Araújo Nobre ◽  
...  

Background: Marginal mandible resection is required to achieve healing in some cases of medication-related osteonecrosis of the jaws (MRONJ). Despite the sparsity of the literature, computer-aided design/computer-aided manufacturing (CAD/CAM) materials may provide superior outcomes for patients with an increased risk of mandible fracture. The aim of this study was to report a digital workflow for surgical interventions to prevent mandible fracture in MRONJ patients. Methods: We present two cases in which virtual surgical planning (VSP) and CAD/CAM surgical guides and reconstruction plates were used to prevent mandible fractures in elderly MRONJ patients submitted for marginal resection. Two osteoporotic patients, aged 73 and 84 years, presented with stage 3 MRONJ of the right mandibular body with inferior alveolar nerve involvement. The unaffected bone height was 6 mm in both cases, implying a high risk of mandible fracture. After preoperative VSP, surgery was performed through a combined intraoral–transbuccal approach. CAD/CAM-customized cutting guides and reconstruction plates were used for the marginal resection of necrotic bone and internal fixation. Results: Complete healing was achieved and the patients remained asymptomatic up to 1 year post-surgery. Conclusions: VSP and CAD/CAM-customized materials facilitated the complete resection of necrotic bone and rigid fixation in MRONJ patients, allowing a simplified approach with shorter operative times, reduced morbidity, and predictable results.

2017 ◽  
Vol 2017 ◽  
pp. 1-6
Author(s):  
Eric L. Chung ◽  
Faizan Alawi ◽  
Anh D. Le ◽  
Rabie M. Shanti

A myriad of extirpative surgical protocols for the management of benign tumors of the jaws have been presented in the literature. Through significant advancements in computer-aided design and computer-aided manufacturing (CAD/CAM) technology and surgical instrumentation, today surgeons have at their disposal robust technology-driven techniques that are aimed at improving surgical outcomes. Our goal is to investigate the benefits of implementing virtual surgical planning (VSP) in conjunction with piezoelectric surgery (PES) to ensure success while minimizing the risk of complications during extirpation of tumors of the mandible. This case report describes the successful extirpation of an ossifying fibroma of the mandible in an adult patient using both VSP and PES.


2016 ◽  
Vol 9 (3) ◽  
pp. 246-250 ◽  
Author(s):  
Andrew Ow ◽  
Winston Tan ◽  
Lukasz Pienkowski

The use of virtual surgical planning and computer-aided design/computer-aided manufacturing has been reported to enhance the planning for the reconstruction of mandibular continuity defects. This case report illustrates the use of this technology in the fabrication of a custom-made titanium prosthesis to restore a segmental mandibular defect. The design specifications and sequence of the custom-made titanium prosthesis are discussed. Although successful in this case, there are limitations in its application and case selection is of vital importance.


Author(s):  
A. N. Bozhko

Computer-aided design of assembly processes (Computer aided assembly planning, CAAP) of complex products is an important and urgent problem of state-of-the-art information technologies. Intensive research on CAAP has been underway since the 1980s. Meanwhile, specialized design systems were created to provide synthesis of assembly plans and product decompositions into assembly units. Such systems as ASPE, RAPID, XAP / 1, FLAPS, Archimedes, PRELEIDES, HAP, etc. can be given, as an example. These experimental developments did not get widespread use in industry, since they are based on the models of products with limited adequacy and require an expert’s active involvement in preparing initial information. The design tools for the state-of-the-art full-featured CAD/CAM systems (Siemens NX, Dassault CATIA and PTC Creo Elements / Pro), which are designed to provide CAAP, mainly take into account the geometric constraints that the design imposes on design solutions. These systems often synthesize technologically incorrect assembly sequences in which known technological heuristics are violated, for example orderliness in accuracy, consistency with the system of dimension chains, etc.An AssemBL software application package has been developed for a structured analysis of products and a synthesis of assembly plans and decompositions. The AssemBL uses a hyper-graph model of a product that correctly describes coherent and sequential assembly operations and processes. In terms of the hyper-graph model, an assembly operation is described as shrinkage of edge, an assembly plan is a sequence of shrinkages that converts a hyper-graph into the point, and a decomposition of product into assembly units is a hyper-graph partition into sub-graphs.The AssemBL solves the problem of minimizing the number of direct checks for geometric solvability when assembling complex products. This task is posed as a plus-sum two-person game of bicoloured brushing of an ordered set. In the paradigm of this model, the brushing operation is to check a certain structured fragment for solvability by collision detection methods. A rational brushing strategy minimizes the number of such checks.The package is integrated into the Siemens NX 10.0 computer-aided design system. This solution allowed us to combine specialized AssemBL tools with a developed toolkit of one of the most powerful and popular integrated CAD/CAM /CAE systems.


Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3819
Author(s):  
Ting-Hsun Lan ◽  
Yu-Feng Chen ◽  
Yen-Yun Wang ◽  
Mitch M. C. Chou

The computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication technique has become one of the hottest topics in the dental field. This technology can be applied to fixed partial dentures, removable dentures, and implant prostheses. This study aimed to evaluate the feasibility of NaCaPO4-blended zirconia as a new CAD/CAM material. Eleven different proportional samples of zirconia and NaCaPO4 (xZyN) were prepared and characterized by X-ray diffractometry (XRD) and Vickers microhardness, and the milling property of these new samples was tested via a digital optical microscope. After calcination at 950 °C for 4 h, XRD results showed that the intensity of tetragonal ZrO2 gradually decreased with an increase in the content of NaCaPO4. Furthermore, with the increase in NaCaPO4 content, the sintering became more obvious, which improved the densification of the sintered body and reduced its porosity. Specimens went through milling by a computer numerical control (CNC) machine, and the marginal integrity revealed that being sintered at 1350 °C was better than being sintered at 950 °C. Moreover, 7Z3N showed better marginal fit than that of 6Z4N among thirty-six samples when sintered at 1350 °C (p < 0.05). The milling test results revealed that 7Z3N could be a new CAD/CAM material for dental restoration use in the future.


Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1986
Author(s):  
Andreas Koenig ◽  
Julius Schmidtke ◽  
Leonie Schmohl ◽  
Sibylle Schneider-Feyrer ◽  
Martin Rosentritt ◽  
...  

The performance of dental resin-based composites (RBCs) heavily depends on the characteristic properties of the individual filler fraction. As specific information regarding the properties of the filler fraction is often missing, the current study aims to characterize the filler fractions of several contemporary computer-aided design/computer-aided manufacturing (CAD/CAM) RBCs from a material science point of view. The filler fractions of seven commercially available CAD/CAM RBCs featuring different translucency variants were analysed using Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray Spectroscopy (EDS), Micro-X-ray Computed Tomography (µXCT), Thermogravimetric Analysis (TG) and X-ray Diffractometry (XRD). All CAD/CAM RBCs investigated included midifill hybrid type filler fractions, and the size of the individual particles was clearly larger than the individual specifications of the manufacturer. The fillers in Shofu Block HC featured a sphericity of ≈0.8, while it was <0.7 in all other RBCs. All RBCs featured only X-ray amorphous phases. However, in Lava Ultimate, zircon crystals with low crystallinity were detected. In some CAD/CAM RBCs, inhomogeneities (X-ray opaque fillers or pores) with a size <80 µm were identified, but the effects were minor in relation to the total volume (<0.01 vol.%). The characteristic parameters of the filler fraction in RBCs are essential for the interpretation of the individual material’s mechanical and optical properties.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1401
Author(s):  
Doo-Bin Song ◽  
Man-So Han ◽  
Si-Chul Kim ◽  
Junyong Ahn ◽  
Yong-Woon Im ◽  
...  

This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses.


Sign in / Sign up

Export Citation Format

Share Document